BibTex RIS Cite

İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi Hearing Aid Selection By Insertion Gain Measurements

Year 2007, Volume: 60 Issue: 1, 45 - 48, 01.01.2007
https://doi.org/10.1501/Tipfak_0000000223

Abstract

References

  • Leijon A, Eriksson- Mangold M, Bech-Karl- sen A. Preferred Hearing Aid Gain and Bass-cut in Relation to Prescriptive Fitting. Scand Audiol 1984;13:157-161.
  • Lundborg T, Risberg A, Holmqvist C et al. Rehabilitative Procedures in Sensorineural Hearing Loss. Scand Audiol 1982;11:161- 166.
  • Akyýldýz N. Ýþitme Cihazlarý. Kulak hastalýklarý ve Mikrocerrahisi. Ankara: Bilimsel Týp Yayý- nevi 2002: 567-588.
  • Esmer N, Akýner MN, Karasalihoðlu AR ve ark. Klinik Odyoloji. Ankara: Özýþýk Matba- cýlýk;1995.
  • Ringdahl A, Leijon A, Liden G. Analysis of Hearing Aid Fittings Using Insertion Gain Measurements. Scand Audiol 1984; 13: 179-185.
  • Humes LE. An Evaluation of Several Rati- onales for Selecting Hearing Aid Gain. J Speech and Hearing Disorders 1986; 51: 272-281.
  • Humes LE, Barlow NN, Garner CB et al. Prescribed Clinician-Fit Versus As-Worn Co- upler Gain in a Group of Elderly Hearing- Aid Wearars. J Speech, Language, and Hea- ring Research 2000; 43: 879-892.
  • Kuk FK. Amplification Devices for the Hea- ring-Impaired Individual. In Cummings CW, Fredricson JM, Harker LA, Krause CJ, Schuller DE. DS, eds. Otolaryngology-He- ad and Neck Surgery, second ed., St Louis: Mosby, 1993: 3127-3141.
  • Leijon A, Eriksson- Mangold M, Bech-Karl- sen A. Preferred Hearing Aid Gain and Bass-cut in Relation to Prescriptive Fitting. Scand Audiol 1984; 13: 157-161.
  • Leijon A, Lindkvist A, Ringdahl A et al. Pre- ferred Hearing Aid Gain in Everyday Use after Prescriptive Fitting. Amplification and Aural Rehabilitation 1990; 11: 299-305.
  • McPherson B, Hickson L, Baumfield A. Cli- nical Reliability of Insertion Gain Measure- ments with Assistive Listening Devices. Scand Audiol 1992; 21:51-54.
  • Norman M, James P. Insertion Gain Measure- ments Using Two Low-Powered Analogue Hearing Aids. British J Audiology 2000; 34: 375-377.
  • Snik AFM, Hombergen GCHJ. Hearing Aid Fitting of Preschool and Primary School Children : An evaluation using the inserti- on gain measurement. Scand Audiol 1993; 22: 245-250.
  • Surr RK, Fabry DA. Comparison of Three Hearing Aid Fittings Using the Speech In- telligibility Rating (SIR) Test. Amplification and Aural Rehabilitation 1991; 12: 32-38.
  • Valente M, Meister M, Smith P et al. Intra- tester Test-Retest Reliability of Insertion Gain Measures. Amplification and Aural Rehabilitation 1990; 11: 181-184.
  • Ringdahl A, Leijon A. The Reliability of In- sertion Gain Measurements Using Probe Microphones in the Ear Canal. Scand Audi- ol 1984; 13: 173-178.
  • Ringdahl A, Leijon A, Liden G et al. Hearing Aid Prescription Rules Using Insertion Ga- in Measurements. Scand Audiol 1984; 13: 211-218.
  • Popelka GR, Gates GA. Hearing aid Evalu- ation and Fitting. The Otolaryngologic Cli- nics of North America 1991; 24: 415-428.
  • Byrne D, Dilon H. The National Acoustic Laboratories' (NAL) New Procedure for Se- lecting the Gain and Frequency Response of a Hearing Aid. Ear and Hearing 1986; 7: 257-265.
  • Thornton ARD, Bell IE, Goodsell S et al. The Use of Flexible Probe Tubes in Inserti- on Gain Measurement. British J Audiology 1987; 21: 295-300.

İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi

Year 2007, Volume: 60 Issue: 1, 45 - 48, 01.01.2007
https://doi.org/10.1501/Tipfak_0000000223

Abstract

Amaç: Bu çalışmada ilk kez işitme cihazı önerilen sensörinöral işitme kayıplı hastalarda invitro kazanç ölçümleri yapılarak optimum kazanç sağlayan işitme cihazlarının belirlenmesi amaçlandı. Gereç ve Yöntem: Ellisekiz hastada işitme cihazı invitro kazanç analizleri yapıldı. Bulgular: Hem subjektif hem de objektif yöntemlerle seçilen işitme cihazlarıyla yüksek performans elde edildi. Takip dönemi boyunca cihazından şikayet eden hasta olmadı. Sonuç: İşitme cihazı invitro kazanç ölçümü pratik ve objektif bir değerlendirme yöntemidir. Bu ölçümler yardımı ile seçilen işitme cihazlarından beklenen performans alınabilmektedir.

References

  • Leijon A, Eriksson- Mangold M, Bech-Karl- sen A. Preferred Hearing Aid Gain and Bass-cut in Relation to Prescriptive Fitting. Scand Audiol 1984;13:157-161.
  • Lundborg T, Risberg A, Holmqvist C et al. Rehabilitative Procedures in Sensorineural Hearing Loss. Scand Audiol 1982;11:161- 166.
  • Akyýldýz N. Ýþitme Cihazlarý. Kulak hastalýklarý ve Mikrocerrahisi. Ankara: Bilimsel Týp Yayý- nevi 2002: 567-588.
  • Esmer N, Akýner MN, Karasalihoðlu AR ve ark. Klinik Odyoloji. Ankara: Özýþýk Matba- cýlýk;1995.
  • Ringdahl A, Leijon A, Liden G. Analysis of Hearing Aid Fittings Using Insertion Gain Measurements. Scand Audiol 1984; 13: 179-185.
  • Humes LE. An Evaluation of Several Rati- onales for Selecting Hearing Aid Gain. J Speech and Hearing Disorders 1986; 51: 272-281.
  • Humes LE, Barlow NN, Garner CB et al. Prescribed Clinician-Fit Versus As-Worn Co- upler Gain in a Group of Elderly Hearing- Aid Wearars. J Speech, Language, and Hea- ring Research 2000; 43: 879-892.
  • Kuk FK. Amplification Devices for the Hea- ring-Impaired Individual. In Cummings CW, Fredricson JM, Harker LA, Krause CJ, Schuller DE. DS, eds. Otolaryngology-He- ad and Neck Surgery, second ed., St Louis: Mosby, 1993: 3127-3141.
  • Leijon A, Eriksson- Mangold M, Bech-Karl- sen A. Preferred Hearing Aid Gain and Bass-cut in Relation to Prescriptive Fitting. Scand Audiol 1984; 13: 157-161.
  • Leijon A, Lindkvist A, Ringdahl A et al. Pre- ferred Hearing Aid Gain in Everyday Use after Prescriptive Fitting. Amplification and Aural Rehabilitation 1990; 11: 299-305.
  • McPherson B, Hickson L, Baumfield A. Cli- nical Reliability of Insertion Gain Measure- ments with Assistive Listening Devices. Scand Audiol 1992; 21:51-54.
  • Norman M, James P. Insertion Gain Measure- ments Using Two Low-Powered Analogue Hearing Aids. British J Audiology 2000; 34: 375-377.
  • Snik AFM, Hombergen GCHJ. Hearing Aid Fitting of Preschool and Primary School Children : An evaluation using the inserti- on gain measurement. Scand Audiol 1993; 22: 245-250.
  • Surr RK, Fabry DA. Comparison of Three Hearing Aid Fittings Using the Speech In- telligibility Rating (SIR) Test. Amplification and Aural Rehabilitation 1991; 12: 32-38.
  • Valente M, Meister M, Smith P et al. Intra- tester Test-Retest Reliability of Insertion Gain Measures. Amplification and Aural Rehabilitation 1990; 11: 181-184.
  • Ringdahl A, Leijon A. The Reliability of In- sertion Gain Measurements Using Probe Microphones in the Ear Canal. Scand Audi- ol 1984; 13: 173-178.
  • Ringdahl A, Leijon A, Liden G et al. Hearing Aid Prescription Rules Using Insertion Ga- in Measurements. Scand Audiol 1984; 13: 211-218.
  • Popelka GR, Gates GA. Hearing aid Evalu- ation and Fitting. The Otolaryngologic Cli- nics of North America 1991; 24: 415-428.
  • Byrne D, Dilon H. The National Acoustic Laboratories' (NAL) New Procedure for Se- lecting the Gain and Frequency Response of a Hearing Aid. Ear and Hearing 1986; 7: 257-265.
  • Thornton ARD, Bell IE, Goodsell S et al. The Use of Flexible Probe Tubes in Inserti- on Gain Measurement. British J Audiology 1987; 21: 295-300.
There are 20 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Ozan Bağış Özgürsoy This is me

Babür Küçük This is me

Publication Date January 1, 2007
Published in Issue Year 2007 Volume: 60 Issue: 1

Cite

APA Özgürsoy, O. B., & Küçük, B. (2007). İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi. Ankara Üniversitesi Tıp Fakültesi Mecmuası, 60(1), 45-48. https://doi.org/10.1501/Tipfak_0000000223
AMA Özgürsoy OB, Küçük B. İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi. Ankara Üniversitesi Tıp Fakültesi Mecmuası. January 2007;60(1):45-48. doi:10.1501/Tipfak_0000000223
Chicago Özgürsoy, Ozan Bağış, and Babür Küçük. “İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi”. Ankara Üniversitesi Tıp Fakültesi Mecmuası 60, no. 1 (January 2007): 45-48. https://doi.org/10.1501/Tipfak_0000000223.
EndNote Özgürsoy OB, Küçük B (January 1, 2007) İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi. Ankara Üniversitesi Tıp Fakültesi Mecmuası 60 1 45–48.
IEEE O. B. Özgürsoy and B. Küçük, “İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi”, Ankara Üniversitesi Tıp Fakültesi Mecmuası, vol. 60, no. 1, pp. 45–48, 2007, doi: 10.1501/Tipfak_0000000223.
ISNAD Özgürsoy, Ozan Bağış - Küçük, Babür. “İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi”. Ankara Üniversitesi Tıp Fakültesi Mecmuası 60/1 (January 2007), 45-48. https://doi.org/10.1501/Tipfak_0000000223.
JAMA Özgürsoy OB, Küçük B. İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi. Ankara Üniversitesi Tıp Fakültesi Mecmuası. 2007;60:45–48.
MLA Özgürsoy, Ozan Bağış and Babür Küçük. “İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi”. Ankara Üniversitesi Tıp Fakültesi Mecmuası, vol. 60, no. 1, 2007, pp. 45-48, doi:10.1501/Tipfak_0000000223.
Vancouver Özgürsoy OB, Küçük B. İnvitro Kazanç Analizleriyle İşitme Cihazı Seçimi. Ankara Üniversitesi Tıp Fakültesi Mecmuası. 2007;60(1):45-8.