Research Article

Optimization of contraction cone length in an open-circuit wind tunnel

Volume: 26 Number: 2 July 15, 2024
TR EN

Optimization of contraction cone length in an open-circuit wind tunnel

Abstract

The studies in the literature mostly focus on the curvature of the contraction cone, while research regarding the impact of contraction length on flow characteristics is limited. This study aims to determine the optimal length of the contraction cone, which ensures uniform flow at the outlet section, considering the wall shear factor. Four contraction cones of varying lengths were designed based on the hydraulic radius of the inlet. Numerical analysis was conducted to obtain static pressure and velocity distributions for the designed geometries. It was observed that wind tunnels designed with contraction cone lengths 2, 3, and 3.5 times the inlet hydraulic radius exhibited similar flow patterns. However, a longer contraction curve minimizes flow disturbances and turbulence, thereby enhancing flow uniformity and steadiness, while thicker boundary layers result from increased wall shears due to boundary layer growth. Consequently, it was concluded that a wind tunnel configured with a contraction cone length of 2 times the inlet hydraulic radius (square contraction cone) is the optimal choice, considering the combined effects of wall shear and flow uniformity.

Keywords

References

  1. Witoszynski, C., Votraege aus dem gebiet der hydro- und aerodynamik, aus Stroemungstechnisches Messwesen bei S.G. Popow, VEB Verlag Technik Berlin, (1960).
  2. Li, H., Chen, C., Liu, B., & Zhang, L., Flow quality analysis of contraction section and test section of low-speed wind tunnel based on CFD numerical simulation. Journal of Physics: Conference Series, vol. 1176, no. 5, p. 052064. IOP Publishing, (2019).
  3. Morel, T. Design of two-dimensional wind tunnel contractions. ASME Journal of Fluids Engineering, vol. 99, pp. 371-378, (1977).
  4. Bell, J. H., and Mehta, R. D. Contraction Design for Small Low Speed Wind Tunnels. NASA Contractor Rep. No. NASA-CR-177488, (1988).
  5. Zanoun, E. S. Flow characteristics in low-speed wind tunnel contractions: Simulation and testing. Alexandria engineering journal, vol. 57, no. 4, , pp. 2265-2277, (2018).
  6. Lastra, M. R. et al. Novel design and experimental validation of a contraction nozzle for aerodynamic measurements in a subsonic wind tunnel. Journal of Wind Engineering and Industrial Aerodynamics, vol. 118, pp. 35-43, (2013).
  7. Ahmed, D. E., & Eljack, E. M. Optimization of model wind-tunnel contraction using CFD. International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, (2014).
  8. Hoghooghi, H., Ahmadabadi, M. N., & Manshadi, M. D. Optimization of a subsonic wind tunnel nozzle with low contraction ratio via ball-spine inverse design method. Journal of mechanical science and technology, vol. 30, no. 5, pp. 2059-2067, (2016).

Details

Primary Language

English

Subjects

Computational Methods in Fluid Flow, Heat and Mass Transfer (Incl. Computational Fluid Dynamics)

Journal Section

Research Article

Early Pub Date

July 14, 2024

Publication Date

July 15, 2024

Submission Date

August 8, 2023

Acceptance Date

April 4, 2024

Published in Issue

Year 2024 Volume: 26 Number: 2

APA
Durmuş, S. (2024). Optimization of contraction cone length in an open-circuit wind tunnel. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 26(2), 431-440. https://doi.org/10.25092/baunfbed.1339334
AMA
1.Durmuş S. Optimization of contraction cone length in an open-circuit wind tunnel. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2024;26(2):431-440. doi:10.25092/baunfbed.1339334
Chicago
Durmuş, Seyhun. 2024. “Optimization of Contraction Cone Length in an Open-Circuit Wind Tunnel”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 26 (2): 431-40. https://doi.org/10.25092/baunfbed.1339334.
EndNote
Durmuş S (July 1, 2024) Optimization of contraction cone length in an open-circuit wind tunnel. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 26 2 431–440.
IEEE
[1]S. Durmuş, “Optimization of contraction cone length in an open-circuit wind tunnel”, Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol. 26, no. 2, pp. 431–440, July 2024, doi: 10.25092/baunfbed.1339334.
ISNAD
Durmuş, Seyhun. “Optimization of Contraction Cone Length in an Open-Circuit Wind Tunnel”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 26/2 (July 1, 2024): 431-440. https://doi.org/10.25092/baunfbed.1339334.
JAMA
1.Durmuş S. Optimization of contraction cone length in an open-circuit wind tunnel. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2024;26:431–440.
MLA
Durmuş, Seyhun. “Optimization of Contraction Cone Length in an Open-Circuit Wind Tunnel”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol. 26, no. 2, July 2024, pp. 431-40, doi:10.25092/baunfbed.1339334.
Vancouver
1.Seyhun Durmuş. Optimization of contraction cone length in an open-circuit wind tunnel. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2024 Jul. 1;26(2):431-40. doi:10.25092/baunfbed.1339334

Cited By