Abstract

After sample vaporization in two-step atomizer with a purged vaporizer sample vapors can be transferred into preheated or into non-heated atomizer. In the last case the atomizer walls trap the vapors and then the sample is second time vaporized and atomized by heating the atomizer. Thermal pre-treatment of a sample using this double vaporization makes possible the direct analysis of samples with strongly interfering matrices including solids. The technique was used for the direct determination of Cd and Pb in human urine, high concentrated water solutions of NaCl, Na2SO4, NaNO3, KH2PO4 and NH4H2PO4 matrices, potatoes, wheat, bovine liver, milk powder, grass-cereals mixture, caprolactam, bituminousshale and polyvinyl chloride plastic without chemical modification or any other sample pretreatment

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Ilia Grinshteiı This is me

Yuri Vilpan This is me

Alexei Saraev This is me

Lubov Vasilieva This is me

Publication Date

June 1, 2001

Submission Date

June 1, 2001

Acceptance Date

-

Published in Issue

Year 2001 Volume: 3 Number: 1

APA
Grinshteiı, I., Vilpan, Y., Saraev, A., & Vasilieva, L. (2001). Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 3(1), 34-54. https://izlik.org/JA24CK67BX
AMA
1.Grinshteiı I, Vilpan Y, Saraev A, Vasilieva L. Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2001;3(1):34-54. https://izlik.org/JA24CK67BX
Chicago
Grinshteiı, Ilia, Yuri Vilpan, Alexei Saraev, and Lubov Vasilieva. 2001. “Methods of Sample Thermal Modification by Means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3 (1): 34-54. https://izlik.org/JA24CK67BX.
EndNote
Grinshteiı I, Vilpan Y, Saraev A, Vasilieva L (June 1, 2001) Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3 1 34–54.
IEEE
[1]I. Grinshteiı, Y. Vilpan, A. Saraev, and L. Vasilieva, “Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis”, Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol. 3, no. 1, pp. 34–54, June 2001, [Online]. Available: https://izlik.org/JA24CK67BX
ISNAD
Grinshteiı, Ilia - Vilpan, Yuri - Saraev, Alexei - Vasilieva, Lubov. “Methods of Sample Thermal Modification by Means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3/1 (June 1, 2001): 34-54. https://izlik.org/JA24CK67BX.
JAMA
1.Grinshteiı I, Vilpan Y, Saraev A, Vasilieva L. Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi. 2001;3:34–54.
MLA
Grinshteiı, Ilia, et al. “Methods of Sample Thermal Modification by Means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, vol. 3, no. 1, June 2001, pp. 34-54, https://izlik.org/JA24CK67BX.
Vancouver
1.Ilia Grinshteiı, Yuri Vilpan, Alexei Saraev, Lubov Vasilieva. Methods of Sample Thermal Modification by means Double Vaporization in Two Step Atomizer for Atomic Absorption Analysis. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi [Internet]. 2001 Jun. 1;3(1):34-5. Available from: https://izlik.org/JA24CK67BX