In this study one year data of grid connected system with thin film a-Si
technologies in Batman province which has 2.16 kWp power and their module
performance comparisons were evaluated according to external parameters. The
data set covers from January until December 2016. The thin film a-Si PV system
supplied 2.631 MWh energy to the grid during 2016. The final yield (Yf) this PV
system ranged from 1.13 to 4.89 kWh/kWp/day and the performance ratio (PO)
ranged from 53 to 78%. The effect of ambient and module temperatures on the
system performance is calculated in the range 6% to 9%. It has also been
determined that other parts of PV system affect system performance at various
ratios.
Bu çalışmada Batman
ilinde ince film a-Si teknolojisine sahip 2.16 kWp güce sahip şebeke bağlantılı
sistemin bir yıllık elektrik enerjisi üretim verileri alınmış ve modüllerin
performansı dış parametrelerde göz önüne alınarak değerlendirilmiştir. Sistem
ölçümleri Ocak ayından Aralık ayına kadar tüm 2016 yılını kapsamaktadır. İnce
film a-Si PV sistemden 2016 yılı süresince şebekeye 2.631 MWh enerji
sağlanmıştır. Sistemin nihai verimi (Yf) 1.13 den 4.89
kWh/KWp/gün’e, performans oranı da (PO) %53 ile %78 arasında değişmektedir.
Ortam ve buna bağlı olarak modül sıcaklıklarının sistem performansına etkisinin
%6 - %9 arasında olduğu hesaplanmıştır. Ayrıca diğer sistem bölümlerinin de
sistem performansı üzerinde değişen oranlarda etkili olduğu belirlenmiştir.
| Subjects | Engineering |
|---|---|
| Journal Section | Research Article |
| Authors | |
| Submission Date | October 4, 2017 |
| Publication Date | July 17, 2018 |
| Published in Issue | Year 2018 Volume: 20 Issue: 1 |