BibTex RIS Cite

A Complication of Venous Cut-Down: Migration of a Catheter That Remained in the Vein

Year 2005, Volume: 2005 Issue: 2, 102 - 105, 01.02.2005
https://izlik.org/JA54YH43RW

Abstract

A 32-year-old male patient who was followed-up with a diagnosis of amyotrophic lateral sclerosis was inserted a catheter into the left arm via cephalic vein cut-down in order to maintain parenteral nutrition and medical treatment. After the treatment, while the catheter was being removed, it was broken and a large part of it remained in the vessel. The catheter was located on a posteroanterior chest radiograph and removed by venotomy of the subclavian vein. Turkish Başlık: Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu Anahtar Kelimeler: Kateterizasyon/yöntem/yan etki; subklaviyan ven/cerrahi; venöz cut-down/yöntem/yan etki Amiyotrofik lateral skleroz tanısıyla takip edilen, parenteral besleme ve tıbbi tedavi amacıyla sol kolda sefalik vene cut-down yaklaşımıyla santral kateterizasyon uygulanan 32 yaşındaki bir erkek hastada, gerekli tedavilerin tamamlanmasından sonra kateterin çekilmesi aşamasında kateter koparak büyük bir kısmı hastanın venöz yapıları içinde kaldı. Posterior-anterior akciğer grafisinde yeri bulunan kateter, subklaviyan venden yapılan venotomi ile çıkarıldı.

References

  • Mermel LA. Prevention of intravascular catheter- related infections. Ann Intern Med 2000;132:391-402.
  • Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol 1953;39:368-76.
  • Sznajder JI, Zveibil FR, Bitterman H, Weiner P, Bursztein S. Central vein catheterization. Failure and complication rates by three percutaneous approach- es. Arch Intern Med 1986;146:259-61.
  • Newman BM, Jewett TC Jr, Karp MP, Cooney DR. Percutaneous central venous catheterization in chil- dren: first line choice for venous access. J Pediatr Surg 1986;21:685-8.

Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu

Year 2005, Volume: 2005 Issue: 2, 102 - 105, 01.02.2005
https://izlik.org/JA54YH43RW

Abstract

Amiyotrofik lateral skleroz tanısıyla takip edilen, parenteral besleme ve tıbbi tedavi amacıyla sol kolda sefalik vene cut-down yaklaşımıyla santral kateterizasyon uygulanan 32 yaşındaki bir erkek hastada, gerekli tedavilerin tamamlanmasından sonra kateterin çekilmesi aşamasında kateter koparak büyük bir kısmı hastanın venöz yapıları içinde kaldı. Posterior-anterior akciğer grafisinde yeri bulunan kateter, subklaviyan venden yapılan venotomi ile çıkarıldı.

References

  • Mermel LA. Prevention of intravascular catheter- related infections. Ann Intern Med 2000;132:391-402.
  • Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol 1953;39:368-76.
  • Sznajder JI, Zveibil FR, Bitterman H, Weiner P, Bursztein S. Central vein catheterization. Failure and complication rates by three percutaneous approach- es. Arch Intern Med 1986;146:259-61.
  • Newman BM, Jewett TC Jr, Karp MP, Cooney DR. Percutaneous central venous catheterization in chil- dren: first line choice for venous access. J Pediatr Surg 1986;21:685-8.
There are 4 citations in total.

Details

Primary Language Turkish
Authors

Mustafa Edis This is me

Turan Ege This is me

Enver Duran This is me

Publication Date February 1, 2005
IZ https://izlik.org/JA54YH43RW
Published in Issue Year 2005 Volume: 2005 Issue: 2

Cite

APA Edis, M., Ege, T., & Duran, E. (2005). Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu. Balkan Medical Journal, 2005(2), 102-105. https://izlik.org/JA54YH43RW
AMA 1.Edis M, Ege T, Duran E. Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu. Balkan Medical Journal. 2005;2005(2):102-105. https://izlik.org/JA54YH43RW
Chicago Edis, Mustafa, Turan Ege, and Enver Duran. 2005. “Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu”. Balkan Medical Journal 2005 (2): 102-5. https://izlik.org/JA54YH43RW.
EndNote Edis M, Ege T, Duran E (February 1, 2005) Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu. Balkan Medical Journal 2005 2 102–105.
IEEE [1]M. Edis, T. Ege, and E. Duran, “Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu”, Balkan Medical Journal, vol. 2005, no. 2, pp. 102–105, Feb. 2005, [Online]. Available: https://izlik.org/JA54YH43RW
ISNAD Edis, Mustafa - Ege, Turan - Duran, Enver. “Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu”. Balkan Medical Journal 2005/2 (February 1, 2005): 102-105. https://izlik.org/JA54YH43RW.
JAMA 1.Edis M, Ege T, Duran E. Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu. Balkan Medical Journal. 2005;2005:102–105.
MLA Edis, Mustafa, et al. “Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu”. Balkan Medical Journal, vol. 2005, no. 2, Feb. 2005, pp. 102-5, https://izlik.org/JA54YH43RW.
Vancouver 1.Mustafa Edis, Turan Ege, Enver Duran. Venöz Cut-Down Komplikasyonu: Bir Olguda Ven İçinde Kalan Kateterin Migrasyonu. Balkan Medical Journal [Internet]. 2005 Feb. 1;2005(2):102-5. Available from: https://izlik.org/JA54YH43RW