Research Article

Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

Volume: 2013 Number: 1 January 1, 2013
  • Bora Uysal
  • Murat Beyzadeoğlu
  • Ömer Sager
  • Ferrat Dinçoğlan
  • Selçuk Demiral
  • Hakan Gamsız
  • Serdar Sürenkök
  • Kaan Oysul
EN TR

Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

Abstract

Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT) and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy) and rectal V40 (the volume receiving 40 Gy) and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles. Turkish Anahtar Kelimeler: Prostat kanseri, YART, 3-B Konformal RT Amaç: Bu dozimetrik çalışmanın amacı 7-alan Yoğunluk Ayarlı Radyoterapi (YART) ve 3-Boyutlu 4-Alan Konformal Radyoterapi (3BKRT)'nin hedef doz homojenitesi ve kritik organ dozlarının karşılaştırılmasıdır. Gereç ve Yöntemler: Gülhane Askeri Tıp Fakültesi Radyasyon Onkolojisi Anabilim Dalı'nda Ocak 2009 ve Aralık 2009 yılları arasında düşük ve orta riskli prostat kanseri tanısıyla tedavi edilen 20 hasta bu çalışmaya dahil edildi. 7-alan Yoğunluk Ayarlı Radyoterapi (YART) ve 3BKRT'nin her ikisi için ayrı iki dozimetrik plan 7-alan YART uygulanan tüm hastaları ve her iki tekniğin dozimetrik durumunu değerlendirmek için düzenlendi. Bulgular: İki tekniğin doz karşılaştırmalı değerlendirilmesi YART tekniğinin istatistiksel olarak belirgin oranda düşük femur başı dozları ile azalmış mesane V60( 60 Gy alan volüm) ve rektal V40 ( 40 Gy alan volüm) kritik organ doz volüm parametreleriyle üstünlüğünü gösterdi. Sonuç: Sonuç olarak YART gelişmiş kritik organ koruma ve hedef organlar olan prostat ve seminal veziküllerin mükemmel doz homojenizasyonuyla prostat kanserinde etkili ve küratif bir tedavi aracıdır.

Keywords

References

  1. Beyzadeoğlu M, Ozyigit G, Ebruli C, editors. Basic Radiation Oncology. Berlin:Springer;2008. p.363-385.
  2. Hanks GE, Leibel SA, Kral JM. Patterns of care studies:doseresponse observations for local control of adenocarcinoma of the prostate. Int J Radiat Oncol Biol Phys 1985;11:153-7. [CrossRef]
  3. Hanks GE, Martz KL, Diamond JJ. The effect of dose on local control of prostate cancer. Int J Radiat Oncol Biol Phys 1988;15:1299-305. [CrossRef]
  4. Sandler HM, Perez-Tamayo C, Ten Haken RK. Dose escalation for stage C (T3) prostate cancer:minimal toxicity observed using conformal therapy. Radiother Oncol 1992;23:53-4. [CrossRef]
  5. Hanks GE, Hanlon AL, Schultheiss TE. Dose escalation with 3D conformal treatment:five year outcomes, treatment optimization, and future directions. Int J Radiat Oncol Biol Phys 1998;41:501-10. [CrossRef]
  6. Zelefsky MJ, Leibel SA, Gaudin PB. Dose escalation with threedimensional conformal radiation therapy affects the outcome in prostate cancer. Int J Radiat Oncol Biol Phys 1998;41:491-500. [CrossRef]
  7. Michalski JM, Purdy JA, Winter K. Preliminary report of toxicity following 3D radiation therapy for prostate cancer on 3DOG/ RTOG 94-06. Int J Radiat Oncol Biol Phys 2000;46:391-402. [CrossRef]
  8. Ryu JK, Winter K, Michalski JM. Interim report of toxicity from 3D conformal radiation therapy (3D-CRT) for prostate cancer on 3DOG/RTOG 9406, level III (79.2 Gy). Int J Radiat Oncol Biol Phys 2002;54:1036-46. [CrossRef]

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Authors

Bora Uysal This is me

Murat Beyzadeoğlu This is me

Ömer Sager This is me

Ferrat Dinçoğlan This is me

Selçuk Demiral This is me

Hakan Gamsız This is me

Serdar Sürenkök This is me

Kaan Oysul This is me

Publication Date

January 1, 2013

Submission Date

August 7, 2014

Acceptance Date

-

Published in Issue

Year 2013 Volume: 2013 Number: 1

APA
Uysal, B., Beyzadeoğlu, M., Sager, Ö., Dinçoğlan, F., Demiral, S., Gamsız, H., Sürenkök, S., & Oysul, K. (2013). Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment. Balkan Medical Journal, 2013(1), 54-57. https://doi.org/10.5152/balkanmedj.2012.075
AMA
1.Uysal B, Beyzadeoğlu M, Sager Ö, et al. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment. Balkan Medical Journal. 2013;2013(1):54-57. doi:10.5152/balkanmedj.2012.075
Chicago
Uysal, Bora, Murat Beyzadeoğlu, Ömer Sager, et al. 2013. “Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment”. Balkan Medical Journal 2013 (1): 54-57. https://doi.org/10.5152/balkanmedj.2012.075.
EndNote
Uysal B, Beyzadeoğlu M, Sager Ö, Dinçoğlan F, Demiral S, Gamsız H, Sürenkök S, Oysul K (January 1, 2013) Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment. Balkan Medical Journal 2013 1 54–57.
IEEE
[1]B. Uysal et al., “Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment”, Balkan Medical Journal, vol. 2013, no. 1, pp. 54–57, Jan. 2013, doi: 10.5152/balkanmedj.2012.075.
ISNAD
Uysal, Bora - Beyzadeoğlu, Murat - Sager, Ömer - Dinçoğlan, Ferrat - Demiral, Selçuk - Gamsız, Hakan - Sürenkök, Serdar - Oysul, Kaan. “Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment”. Balkan Medical Journal 2013/1 (January 1, 2013): 54-57. https://doi.org/10.5152/balkanmedj.2012.075.
JAMA
1.Uysal B, Beyzadeoğlu M, Sager Ö, Dinçoğlan F, Demiral S, Gamsız H, Sürenkök S, Oysul K. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment. Balkan Medical Journal. 2013;2013:54–57.
MLA
Uysal, Bora, et al. “Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment”. Balkan Medical Journal, vol. 2013, no. 1, Jan. 2013, pp. 54-57, doi:10.5152/balkanmedj.2012.075.
Vancouver
1.Bora Uysal, Murat Beyzadeoğlu, Ömer Sager, Ferrat Dinçoğlan, Selçuk Demiral, Hakan Gamsız, Serdar Sürenkök, Kaan Oysul. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment. Balkan Medical Journal. 2013 Jan. 1;2013(1):54-7. doi:10.5152/balkanmedj.2012.075