Research Article
BibTex RIS Cite
Year 2021, Volume: 4 Issue: 1, 22 - 25, 01.01.2021
https://doi.org/10.19127/bshealthscience.806465

Abstract

References

  • Ahn SJ, Hong SH, Chai JW, Choi JY, Yoo HJ, Kim SH, Kang HS. 2014. Comparison of image quality of shoulder CT arthrography conducted Using 120 kVp and 140 kVp protocols. Korean J Radiol, 15(6): 739-745.
  • Aytac SK, Yigit H, Sancak T, Ozcan H. 2003. Correlation between the diameter of the main renal artery and the presence of an accessory renal artery - Sonographic and angiographic evaluation. J Ultrasound in Med, 22(5): 433-439.
  • Budovec JJ, Pollema M, Grogan M. 2010. Update on multidetector computed tomography angiography of the abdominal aorta. Radiol Clin North America, 48(2): 283-309.
  • Bulic K, Ivkic G, Pavic T. 1996. A case of duplicated right renal artery and triplicated left renal artery. Annals of Anatomy-Anatomischer Anzeiger, 178(3): 281-283.
  • Cinar C, Turkvatan A. (2016). Prevalence of renal vascular variations: Evaluation with MDCT angiography. Diagnostic Intervent Imaging, 97(9): 891-897.
  • Gumus H, Bukte Y, Ozdemir E, Cetincakmak MG, Tekbas G, Ekici F, Uyar A. 2012. Variations of renal artery in 820 patients using 64-detector ct-angiography. Renal Failure, 34(3): 286-290.
  • Hanninen E, Denecke T, Stelter L. 2005. Preoperative evaluation of living kidney donors using multirow detector computed tomography. Transpl Int, 18: 1134–1141.
  • Holden A, Smith A, Dukes P, Pilmore H, Yasutomi M. 2005. Assessment of 100 live potential renal donors for laparoscopic nephrectomy with multi-detector row helical CT. Radiology, 237(3): 973-980.
  • Hung CJ, Lin YJ, Chang SS, Chou TC, Lee PC. 2012. Kidney grafts with multiple renal arteries is no longer a relative contraindication with advance in surgical techniques of laparoscopic donor nephrectomy. Transplant Proc, 44(1): 36-38.
  • Khamanarong K, Prachaney P, Utaravichien A, Tong-Un T, Sripaoraya K. 2004. Anatomy of renal arterial supply. Clinical Anat, 17(4): 334-336.
  • Koc Z, Ulusan S, Oguzkurt L. 2007. Association of left renal vein variations and pelvic varices in abdominal MDCT. Eur Radiol, 17(5): 1267-1274.
  • Kuczera P, Wloszczynska E, Adamczak M, Pencak P, Chudek J, Wiecek A. 2009. Frequency of renal artery stenosis and variants of renal vascularization in hypertensive patients: analysis of 1550 angiographies in one centre. J Hum Hypertens, 23(6): 396-401.
  • Kumar S, Neyaz Z, Gupta A. 2010. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay. Korean J Radiol, 11(3): 346-354.
  • Oner S, Oner Z. 2019. Variations of Arteria renalis: a study of multidedector CT angiography. Kafkas J Med Sci, 9(1): 1-5.
  • Ozkan U, Oguzkurt L, Tercan F, Kizilkilic O, Koc Z, Koca N. 2006. Renal artery origins and variations: angiographic evaluation of 855 consecutive patients. Diagn Interv Radiol, 12(4): 183-186.
  • Ramadan SU, Yigit H, Gokharman D, Tuncbilek I, Dolgun NA, Kosar P, Kosar U. 2011. Can renal dimensions and the main renal artery diameter indicate the presence of an accessory renal artery? A 64-slice CT study. Diagnostic and Interventional Radiol, 17(3): 266-271.
  • Saba L, Sanfilippo R, Montisci R, Conti M, Mallarini G. 2008. Accessory renal artery stenosis and hypertension: Are these correlated? Evaluation using multidetector-row computed tomographic angiography. Acta Radiologica, 49(3): 278-284.
  • Secen O, Akbulut M, Harman M, Yavcın O. 2014. Frequency of accessory renal artery in hypertensive patients. MN Cardiol, 21(3): 151.
  • Shoja MM, Tubbs RS, Shakeri A, Loukas M, Ardalan MR, Khosroshahi HT, Oakes WJ. 2008. Peri-hilar branching patterns and morphologies of the renal artery: a review and anatomical study. Surg and Radiol Anat, 30(5): 375-382.
  • Ugurel MS, Battal B, Bozlar U, Nural MS, Tasar M, Ors F, Karademir I. 2010. Anatomical variations of hepatic arterial system, coeliac trunk and renal arteries: an analysis with multidetector CT angiography. British J Radiol, 83(992): 661-667.
  • Urban BA, Ratner LE, Fishman EK. 2001. Three-dimensional volume-rendered CT angiography of the renal arteries and veins: Normal anatomy, variants, and clinical applications. Radiographics, 21(2): 373-386.
  • Vazquez R, Garcia L, Morales-Buenrostro L, Gabilondo B, Alberu J, Vilatoba M. 2010. Renal grafts with multiple arteries: a relative contraindication for a renal transplant? Transplant Proc, 42(6): 2369-2371.

Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique

Year 2021, Volume: 4 Issue: 1, 22 - 25, 01.01.2021
https://doi.org/10.19127/bshealthscience.806465

Abstract

It is necessary to have a comprehensive knowledge about renal vascular anatomy in order to be able to apply renal surgical
procedures correctly. The renal artery is a pair to feed the right and left kidneys. Its variation is common. In this study, it was aimed to
group the variations and to examine them clinically. Abdominal CT findings of 532 cases examined with MDCT device were included in
the study. Variation was detected in 135 (25.3%) of 532 cases. Of these variations, 95 (17.8%) were early branching and 40 (7.5%)
were extra renal artery variations. The presence of renal artery variation may cause complications in surgical procedures such as
kidney transplantation. Knowing the variations before the intervention to be made in the region will be guiding.

References

  • Ahn SJ, Hong SH, Chai JW, Choi JY, Yoo HJ, Kim SH, Kang HS. 2014. Comparison of image quality of shoulder CT arthrography conducted Using 120 kVp and 140 kVp protocols. Korean J Radiol, 15(6): 739-745.
  • Aytac SK, Yigit H, Sancak T, Ozcan H. 2003. Correlation between the diameter of the main renal artery and the presence of an accessory renal artery - Sonographic and angiographic evaluation. J Ultrasound in Med, 22(5): 433-439.
  • Budovec JJ, Pollema M, Grogan M. 2010. Update on multidetector computed tomography angiography of the abdominal aorta. Radiol Clin North America, 48(2): 283-309.
  • Bulic K, Ivkic G, Pavic T. 1996. A case of duplicated right renal artery and triplicated left renal artery. Annals of Anatomy-Anatomischer Anzeiger, 178(3): 281-283.
  • Cinar C, Turkvatan A. (2016). Prevalence of renal vascular variations: Evaluation with MDCT angiography. Diagnostic Intervent Imaging, 97(9): 891-897.
  • Gumus H, Bukte Y, Ozdemir E, Cetincakmak MG, Tekbas G, Ekici F, Uyar A. 2012. Variations of renal artery in 820 patients using 64-detector ct-angiography. Renal Failure, 34(3): 286-290.
  • Hanninen E, Denecke T, Stelter L. 2005. Preoperative evaluation of living kidney donors using multirow detector computed tomography. Transpl Int, 18: 1134–1141.
  • Holden A, Smith A, Dukes P, Pilmore H, Yasutomi M. 2005. Assessment of 100 live potential renal donors for laparoscopic nephrectomy with multi-detector row helical CT. Radiology, 237(3): 973-980.
  • Hung CJ, Lin YJ, Chang SS, Chou TC, Lee PC. 2012. Kidney grafts with multiple renal arteries is no longer a relative contraindication with advance in surgical techniques of laparoscopic donor nephrectomy. Transplant Proc, 44(1): 36-38.
  • Khamanarong K, Prachaney P, Utaravichien A, Tong-Un T, Sripaoraya K. 2004. Anatomy of renal arterial supply. Clinical Anat, 17(4): 334-336.
  • Koc Z, Ulusan S, Oguzkurt L. 2007. Association of left renal vein variations and pelvic varices in abdominal MDCT. Eur Radiol, 17(5): 1267-1274.
  • Kuczera P, Wloszczynska E, Adamczak M, Pencak P, Chudek J, Wiecek A. 2009. Frequency of renal artery stenosis and variants of renal vascularization in hypertensive patients: analysis of 1550 angiographies in one centre. J Hum Hypertens, 23(6): 396-401.
  • Kumar S, Neyaz Z, Gupta A. 2010. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay. Korean J Radiol, 11(3): 346-354.
  • Oner S, Oner Z. 2019. Variations of Arteria renalis: a study of multidedector CT angiography. Kafkas J Med Sci, 9(1): 1-5.
  • Ozkan U, Oguzkurt L, Tercan F, Kizilkilic O, Koc Z, Koca N. 2006. Renal artery origins and variations: angiographic evaluation of 855 consecutive patients. Diagn Interv Radiol, 12(4): 183-186.
  • Ramadan SU, Yigit H, Gokharman D, Tuncbilek I, Dolgun NA, Kosar P, Kosar U. 2011. Can renal dimensions and the main renal artery diameter indicate the presence of an accessory renal artery? A 64-slice CT study. Diagnostic and Interventional Radiol, 17(3): 266-271.
  • Saba L, Sanfilippo R, Montisci R, Conti M, Mallarini G. 2008. Accessory renal artery stenosis and hypertension: Are these correlated? Evaluation using multidetector-row computed tomographic angiography. Acta Radiologica, 49(3): 278-284.
  • Secen O, Akbulut M, Harman M, Yavcın O. 2014. Frequency of accessory renal artery in hypertensive patients. MN Cardiol, 21(3): 151.
  • Shoja MM, Tubbs RS, Shakeri A, Loukas M, Ardalan MR, Khosroshahi HT, Oakes WJ. 2008. Peri-hilar branching patterns and morphologies of the renal artery: a review and anatomical study. Surg and Radiol Anat, 30(5): 375-382.
  • Ugurel MS, Battal B, Bozlar U, Nural MS, Tasar M, Ors F, Karademir I. 2010. Anatomical variations of hepatic arterial system, coeliac trunk and renal arteries: an analysis with multidetector CT angiography. British J Radiol, 83(992): 661-667.
  • Urban BA, Ratner LE, Fishman EK. 2001. Three-dimensional volume-rendered CT angiography of the renal arteries and veins: Normal anatomy, variants, and clinical applications. Radiographics, 21(2): 373-386.
  • Vazquez R, Garcia L, Morales-Buenrostro L, Gabilondo B, Alberu J, Vilatoba M. 2010. Renal grafts with multiple arteries: a relative contraindication for a renal transplant? Transplant Proc, 42(6): 2369-2371.
There are 22 citations in total.

Details

Primary Language English
Subjects Clinical Sciences
Journal Section Research Article
Authors

Güneş Bolatlı 0000-0002-7648-0237

Mahinur Ulusoy 0000-0002-0647-8828

Mustafa Koplay 0000-0001-7513-4968

Musa Acar 0000-0002-5646-693X

İsmail Zararsız 0000-0002-0551-337X

Publication Date January 1, 2021
Submission Date October 6, 2020
Acceptance Date October 26, 2020
Published in Issue Year 2021 Volume: 4 Issue: 1

Cite

APA Bolatlı, G., Ulusoy, M., Koplay, M., Acar, M., et al. (2021). Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique. Black Sea Journal of Health Science, 4(1), 22-25. https://doi.org/10.19127/bshealthscience.806465
AMA Bolatlı G, Ulusoy M, Koplay M, Acar M, Zararsız İ. Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique. BSJ Health Sci. January 2021;4(1):22-25. doi:10.19127/bshealthscience.806465
Chicago Bolatlı, Güneş, Mahinur Ulusoy, Mustafa Koplay, Musa Acar, and İsmail Zararsız. “Investigation of Renal Artery Variations With Multidetector Computed Tomography Angiography Technique”. Black Sea Journal of Health Science 4, no. 1 (January 2021): 22-25. https://doi.org/10.19127/bshealthscience.806465.
EndNote Bolatlı G, Ulusoy M, Koplay M, Acar M, Zararsız İ (January 1, 2021) Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique. Black Sea Journal of Health Science 4 1 22–25.
IEEE G. Bolatlı, M. Ulusoy, M. Koplay, M. Acar, and İ. Zararsız, “Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique”, BSJ Health Sci., vol. 4, no. 1, pp. 22–25, 2021, doi: 10.19127/bshealthscience.806465.
ISNAD Bolatlı, Güneş et al. “Investigation of Renal Artery Variations With Multidetector Computed Tomography Angiography Technique”. Black Sea Journal of Health Science 4/1 (January 2021), 22-25. https://doi.org/10.19127/bshealthscience.806465.
JAMA Bolatlı G, Ulusoy M, Koplay M, Acar M, Zararsız İ. Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique. BSJ Health Sci. 2021;4:22–25.
MLA Bolatlı, Güneş et al. “Investigation of Renal Artery Variations With Multidetector Computed Tomography Angiography Technique”. Black Sea Journal of Health Science, vol. 4, no. 1, 2021, pp. 22-25, doi:10.19127/bshealthscience.806465.
Vancouver Bolatlı G, Ulusoy M, Koplay M, Acar M, Zararsız İ. Investigation of Renal Artery Variations with Multidetector Computed Tomography Angiography Technique. BSJ Health Sci. 2021;4(1):22-5.