Research Article

Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field

Volume: 8 Number: 2 July 1, 2025
EN

Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field

Abstract

This investigation analyzes the physical properties of blood flow via a catheter in a damaged, curved artery while taking mass and heat transfer in a magnetic field. In order to get analytical answers for axial velocity, temperature, and concentration, this study models and solves the set of equations for the incompressible, non-Newtonian Jeffrey fluid under the mild stenosis approximation. The findings show that while there is less barrier to blood flow and concentration, an increase in the parameter of curvature raises shear stress of the artery wall, blood velocity, and temperature. The effect on key factors such as axial velocity, flow rate, resistance impedance, and wall shear stress of arterial geometrical variables such as stenosis, slip parameter, Hartmann number, and catheter parameter is thoroughly and quantitatively analyzed. Moreover, in trapping phenomena, the artery's curvature throws off the symmetry of the trapped bolus.

Keywords

Artery wall, Blood flow, Heat-mass transfer, Jeffery fluid, Magnetic field

References

  1. [1] H. Schlichting, Boundary Layer Theory, McGraw Hill Education Indian Edition 2014, ISBN-13:978-93-329-0282-4, 7th Edition.
  2. [2] S. Chakravarty, Effect of stenosis on the flow behavior of blood in an artery, Int. J. Eng. Sci., 25(8) (1987), 1003-1016. https://doi.org/10.1016/0020-7225(87)90093-0
  3. [3] M. S. Shabbir, N. Ali, Z. Abbas, Unsteady blood flow of non-Newtonian fluid through a rigid artery in the presence of multiirregular stenoses. J. Braz. Soc. Mech. Sci. Eng., 40 (2018), Article ID 413. https://doi.org/10.1007/s40430-018-1327-x
  4. [4] R. Padma, P. Ponalagusamy, R. T. Selvi, Mathematical modeling of electro hydrodynamic non-Newtonian fluid flow through tapered arterial stenosis with periodic body acceleration and applied magnetic field, Appl. Math. Comput., 362 (2019), Article ID 124453. https://doi.org/10.1016/j.amc.2019.05.024
  5. [5] R. K. Dash, G. Jayaraman, K. N. Mehta, Flow in a catheterized curved artery with stenosis, J. Biomech., 32(1) (1999), 49-61. https://doi.org/10.1016/S0021-9290(98)00142-0
  6. [6] M. Ayub, I. Shahzadi, S. Nadeem, A ballon model analysis with Cu-blood medicated nanoparticles as drug agent through overlapped curved stenotic artery having compliant walls, Microsyst. Technol., 25 (2019), 2949-2962. https://doi.org/10.1007/s00542-018-4263-x
  7. [7] A. Zaman, A. A. Khan, Time dependent non-Newtonian nano-fluid (blood) flow in w-shape stenosed channel; with curvature effects, Math. Comput. Simul., 181 (2021), 82-97. https://doi.org/10.1016/j.matcom.2020.09.017
  8. [8] A. Ahmed, S. Nadeem, Shape effect of Cu-nanoparticles in unsteady flow through curved artery with catheterized stenosis, Results Phys., 7 (2017), 677-689. https://doi.org/10.1016/j.rinp.2017.01.015
  9. [9] A. Zaman, N. Ali, M. Sajid, Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery, AIP Adv., 6(1) (2016), Article ID 015118. https://doi.org/10.1063/1.4941358
  10. [10] T. Hayat, N. Ali, S. Asghar, An analysis of peristaltic transport for flow of a Jeffrey fluid, Acta Mech., 193 (2007), 101-112. https://doi.org/10.1007/s00707-007-0468-2
APA
Sethi, G., & Kumar Agarwal, S. (2025). Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field. Communications in Advanced Mathematical Sciences, 8(2), 86-99. https://doi.org/10.33434/cams.1604629
AMA
1.Sethi G, Kumar Agarwal S. Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field. Communications in Advanced Mathematical Sciences. 2025;8(2):86-99. doi:10.33434/cams.1604629
Chicago
Sethi, Gauri, and Surendra Kumar Agarwal. 2025. “Analytic Approach to Non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field”. Communications in Advanced Mathematical Sciences 8 (2): 86-99. https://doi.org/10.33434/cams.1604629.
EndNote
Sethi G, Kumar Agarwal S (July 1, 2025) Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field. Communications in Advanced Mathematical Sciences 8 2 86–99.
IEEE
[1]G. Sethi and S. Kumar Agarwal, “Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field”, Communications in Advanced Mathematical Sciences, vol. 8, no. 2, pp. 86–99, July 2025, doi: 10.33434/cams.1604629.
ISNAD
Sethi, Gauri - Kumar Agarwal, Surendra. “Analytic Approach to Non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field”. Communications in Advanced Mathematical Sciences 8/2 (July 1, 2025): 86-99. https://doi.org/10.33434/cams.1604629.
JAMA
1.Sethi G, Kumar Agarwal S. Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field. Communications in Advanced Mathematical Sciences. 2025;8:86–99.
MLA
Sethi, Gauri, and Surendra Kumar Agarwal. “Analytic Approach to Non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field”. Communications in Advanced Mathematical Sciences, vol. 8, no. 2, July 2025, pp. 86-99, doi:10.33434/cams.1604629.
Vancouver
1.Gauri Sethi, Surendra Kumar Agarwal. Analytic Approach to non-Newtonian Jeffery Fluid Flow in a Catheterized Curved Artery: Exploring the Impact of Heat, Mass Transfer and Magnetic Field. Communications in Advanced Mathematical Sciences. 2025 Jul. 1;8(2):86-99. doi:10.33434/cams.1604629