Research Article

Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite

Volume: 22 Number: 3 September 30, 2026
EN

Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite

Abstract

In this study, a theoretical hybrid composite containing 30 wt.% epoxy, 25 wt.% vermiculite, and 45 wt.% lanthanum hexaboride (LaB₆) was designed for radiation shielding applications, and its shielding performance was evaluated using the EGSnrc Monte Carlo code system. The density of the proposed composite was calculated as 2.25 g/cm³, and its mass attenuation coefficient (MAC), linear attenuation coefficient (LAC), half-value layer (HVL), and lead-equivalent thickness (Pb-Eq) were determined over the photon energy range of 1.0 keV to 3.0 MeV. Furthermore, three-dimensional dose distributions were calculated using the DOSXYZnrc user code to evaluate the dosimetric shielding performance of the composite. The results demonstrated that, despite its low density, the proposed hybrid composite exhibited superior photon attenuation performance compared with vermiculite and ordinary concrete over a broad energy range. Lead-equivalent analyses indicated that the composite thicknesses required to provide shielding equivalent to 0.25 and 0.50 mm Pb varied with photon energy, ranging from approximately 1.3 to 8.0 mm and 2.6 to 16.0 mm, respectively. Dosimetric analyses showed good agreement with the lead-equivalent calculations at photon energies of 120 and 140 keV, whereas at 364 keV the lead-equivalent approach did not accurately represent the actual dose distribution within the phantom, demonstrating that shielding performance at higher photon energies cannot be adequately assessed using conventional attenuation parameters alone. These findings indicate that the proposed Epoxy/Vermiculite/LaB₆ hybrid composite is a promising candidate for the development of lead-free shielding materials, particularly for nuclear medicine applications and for photon energies relevant to diagnostic radiology.

Keywords

References

  1. [1]. Gülbiçim, H, Tufan, MÇ, Türkan, MN. 2017. The investigation of vermiculite as an alternating shielding material for gamma rays. Radiation Physics and Chemistry, 130, 112-117.
  2. [2]. More, CV, Alsayed, Z, Badawi, MS, Thabet, AA, Pawar, PP. 2021. Polymeric composite materials for radiation shielding: a review. Environmental chemistry letters, 19(3), 2057-2090.
  3. [3]. Nambiar, S, Yeow, JT. 2012. Polymer-composite materials for radiation protection. ACS applied materials & interfaces, 4(11), 5717-5726.
  4. [4]. Zeng, C, Kang, Q, Duan, Z, Qin, B, Feng, X, Lu, H, Lin, Y. 2023. Development of polymer composites in radiation shielding applications: a review. Journal of Inorganic and Organometallic Polymers and Materials, 33(8), 2191-2239.
  5. [5]. Çelik, Aİ, Tunç, U, Durmuş, A, Karaköse, E, Alkurt, FÖ, Karaaslan, M. 2026. Electromagnetic shielding performance and mechanical properties of vermiculite-based lightweight geopolymer mortars. Scientific Reports, 16(1), 7865.
  6. [6]. More, CV, Alavian, H, Pawar, PP. 2020. Evaluation of gamma-ray attenuation characteristics of some thermoplastic polymers: Experimental, WinXCom and MCNPX studies. Journal of Non-Crystalline Solids, 546, 120277.
  7. [7]. Prabhu, S, Bubbly, SG, Gudennavar, SB. 2023. X-ray and γ-ray shielding efficiency of polymer composites: choice of fillers, effect of loading and filler size, photon energy and multifunctionality. Polymer Reviews, 63(1), 246-288.
  8. [8]. Alsaab, AH, Zeghib, S. 2023. Analysis of X-ray and gamma ray shielding performance of prepared polymer micro-composites. Journal of Radiation Research and Applied Sciences, 16(4), 100708.

Details

Primary Language

English

Subjects

Atomic, Molecular and Optical Physics (Other)

Journal Section

Research Article

Publication Date

September 30, 2026

Submission Date

July 8, 2026

Acceptance Date

September 17, 2026

Published in Issue

Year 2026 Volume: 22 Number: 3

APA
Gülbiçim, H. (2026). Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite. Celal Bayar University Journal of Science, 22(3), 726-745. https://doi.org/10.18466/cbayarfbe.1989759
AMA
1.Gülbiçim H. Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite. CBUJOS. 2026;22(3):726-745. doi:10.18466/cbayarfbe.1989759
Chicago
Gülbiçim, Hasan. 2026. “Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy Vermiculite LaB₆ Hybrid Composite”. Celal Bayar University Journal of Science 22 (3): 726-45. https://doi.org/10.18466/cbayarfbe.1989759.
EndNote
Gülbiçim H (September 1, 2026) Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite. Celal Bayar University Journal of Science 22 3 726–745.
IEEE
[1]H. Gülbiçim, “Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite”, CBUJOS, vol. 22, no. 3, pp. 726–745, Sept. 2026, doi: 10.18466/cbayarfbe.1989759.
ISNAD
Gülbiçim, Hasan. “Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy Vermiculite LaB₆ Hybrid Composite”. Celal Bayar University Journal of Science 22/3 (September 1, 2026): 726-745. https://doi.org/10.18466/cbayarfbe.1989759.
JAMA
1.Gülbiçim H. Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite. CBUJOS. 2026;22:726–745.
MLA
Gülbiçim, Hasan. “Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy Vermiculite LaB₆ Hybrid Composite”. Celal Bayar University Journal of Science, vol. 22, no. 3, Sept. 2026, pp. 726-45, doi:10.18466/cbayarfbe.1989759.
Vancouver
1.Hasan Gülbiçim. Monte Carlo Evaluation of the Radiation Shielding Performance of an Epoxy/Vermiculite/LaB₆ Hybrid Composite. CBUJOS. 2026 Sep. 1;22(3):726-45. doi:10.18466/cbayarfbe.1989759