Research Article

A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance

Volume: 14 Number: 2 June 30, 2018
EN

A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance

Abstract

This paper examines and presents a simple computational Monte Carlo algorithm to determine the total, intrinsic and geometric efficiencies of  NaI(Tl) gamma ray detectors for gamma rays emitted by isotropic radiating (point) sources with several energies in the range of 150-3000 keV. The code was used to compute efficiency values for various source-to-detector distances for each studied gamma ray energy. The comparisons with the data reported in the literature indicated that the present algorithm is useful in efficiency calculations for any source-detector and geometry configuration.

Keywords

References

  1. 1. Demir, D, Un, A, Sahin, Y, Efficiency Determination for NaI (Tl) Detectors in the 23 keV to 1333 keV Energy Range, Instrumenta-tion Science and Technology, 2008, 36, 291–301.
  2. 2. Abd-Elzaher, M, Badawi, M.S, El-Khatib, A, Thabet, A.A, Deter-mination of Full Energy Peak Efficiency of NaI(Tl) Detector De-pending on Efficiency Transfer Principle for Conversion Form Experimental Values, World Journal of Nuclear Science and Tech-nology, 2012, 2, 65-72.
  3. 3. Zerby, C.D, Moran, H.S, Calculation of the pulse-height response of NaI(Tl) scintillation counters, Nuclear Instruments and Methods, 1961, 14, 115-124.
  4. 4. Beam, G.B, Wielopolski, L, Gardner, R.P, Verghese, K, Monte Carlo calculation of efficiencies of right-circular cylindrical NaI de-tectors for arbitrarily located point sources, Nuclear Instruments and Methods, 1978, 154, 501-508.
  5. 5. Jehouani, A, Ichaoui, R, Boulkheir, M, Study of the NaI(Tl) effici-ency by Monte Carlo method, Applied Radiation and Isotopes, 2000, 53, 887-891.
  6. 6. Mitra, M.S, Sarkar, P.K, Monte Carlo simulations to estimate the background spectrum in a shielded NaI(Tl) g-spectrometric system, Applied Radiation and Isotopes, 2005, 63, 415–422.
  7. 7. Ayaz-Maierhafer, B, DeVol, T.A, Determination of absolute detec-tion efficiencies for detectors of interest in homeland security, Nuc-lear Instruments and Methods in Physics Research A, 2007, 579, 410–413.
  8. 8. Anil Kumar, G, Mazumdar, I, Gothe, D.A, Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl)detectors in soccer-ball and castle geometries, Nuclear Inst-ruments and Methods in Physics Research A, 2009, 611, 76–83.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

June 30, 2018

Submission Date

February 19, 2018

Acceptance Date

June 5, 2018

Published in Issue

Year 2018 Volume: 14 Number: 2

APA
Akar Tarım, U., Gürler, O., & Yalçın, S. (2018). A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. Celal Bayar University Journal of Science, 14(2), 195-199. https://doi.org/10.18466/cbayarfbe.396704
AMA
1.Akar Tarım U, Gürler O, Yalçın S. A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. CBUJOS. 2018;14(2):195-199. doi:10.18466/cbayarfbe.396704
Chicago
Akar Tarım, Urkiye, Orhan Gürler, and Sezai Yalçın. 2018. “A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma Ray Energy and Source-to-Detector Distance”. Celal Bayar University Journal of Science 14 (2): 195-99. https://doi.org/10.18466/cbayarfbe.396704.
EndNote
Akar Tarım U, Gürler O, Yalçın S (June 1, 2018) A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. Celal Bayar University Journal of Science 14 2 195–199.
IEEE
[1]U. Akar Tarım, O. Gürler, and S. Yalçın, “A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance”, CBUJOS, vol. 14, no. 2, pp. 195–199, June 2018, doi: 10.18466/cbayarfbe.396704.
ISNAD
Akar Tarım, Urkiye - Gürler, Orhan - Yalçın, Sezai. “A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma Ray Energy and Source-to-Detector Distance”. Celal Bayar University Journal of Science 14/2 (June 1, 2018): 195-199. https://doi.org/10.18466/cbayarfbe.396704.
JAMA
1.Akar Tarım U, Gürler O, Yalçın S. A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. CBUJOS. 2018;14:195–199.
MLA
Akar Tarım, Urkiye, et al. “A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma Ray Energy and Source-to-Detector Distance”. Celal Bayar University Journal of Science, vol. 14, no. 2, June 2018, pp. 195-9, doi:10.18466/cbayarfbe.396704.
Vancouver
1.Urkiye Akar Tarım, Orhan Gürler, Sezai Yalçın. A Quick Method to Calculate NaI(Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance. CBUJOS. 2018 Jun. 1;14(2):195-9. doi:10.18466/cbayarfbe.396704

Cited By