EN
Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy
Abstract
In this study, the effects of various bolus materials on dose distributions were compared in electron conformal radiotherapy (ECRT). Superflab, Super Stuff pink wax and Paraffin wax bolus materials are used with 15MeV electron energy for dosimetric comparison. Additionally, 10 mm thick Super Stuff pink wax bolus and paraffin wax bolus materials were placed on the right eyelid of a patient. Using electron dose calculation algorithm and ion chamber measurements, dosimetric comparisons were made in the Eclipse treatment planning system (TPS). Both for measured and calculated dose, values were acquired 3 times and averaged for each case. Resulting differences are expressed as percentage differences. Dose differences were obtained in measurements with and without using bolus at several locations of the solid phantom, performed by the Roos Ion chamber. Dosimetric differences of 7-7.5% for Superflab, 10-10.5% for paraffin bolus and 13-14% for Super Stuff pink wax bolus are obtained. Besides, when dosimetric comparisons are made in the treatment planning system for cases with and without bolus; Dose differences were calculated to be 2-2.5% for superflab silicon bolus, 3-3.5% for paraffin wax bolus and 5-6% for Super Stuff pink wax bolus. To increase skin dose in curved anatomical structures in radiotherapy, it is safe to use the paraffin wax bolus material in radiotherapy clinic, as an alternative to Superflab silicon bolus and Super Stuff pink wax bolus materials, due to its low cost and ease of conforming to body surface contours.
Keywords
References
- [1]. Chang F, Chang P, Share F. Study of elasto-gel pads used as surface bolus material in high energy photon and electron therapy. International Journal of Radiation Oncology Biology Physics, 1992;22: 191-93.
- [2]. Vyas V, Palmer L, Mudge R, Jiang R, Fleck A. On bolus for megavoltage photon and electron radiation therapy. Med Dosim. 2013;38: 268–73.
- [3]. Fujimoto K, Shiinoki T, Yuasa Y, Hanazawa H, Shibuya K. Efficacy of patient-specific bolus created using three-dimensional printing technique in photon radiotherapy. Phys Med. 2017;38: 1-9.
- [4]. Ricotti R, Ciardo D, Pansini F, Bazani A, Comi S, Spoto R et al. Dosimetric characterization of 3D printed bolus at different infill percentage for external photon beam radiotherapy. Phys Med. 2017;39: 25-32.
- [5]. Banaee N, Nedaie H.A, Nosrati H, Nabavi M, Naderi M. Dose measurement of different bolus materials on surface dose. Journal of Radioprotection Research, 2013; 1(1): 10-3.
- [6]. Malaescu I, Marin C.N, Spunei M. Comparative study on the surface dose of some bolus materials. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2015; 4:348-52.
- [7]. Burleson S, Baker J, Hsia A.T, Zhigang X. Use of 3D printers to create a patient‐specific 3D bolus for external beam therapy. Journal of Applied Clinical Medical Physics, 2015;16(3):166-178.
- [8]. Court LE, Tishler RB, Allen AM. Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system. Journal of Applied Clinical Medical Physics 2008; 9(1):29-35.
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Publication Date
June 24, 2020
Submission Date
December 3, 2019
Acceptance Date
June 23, 2020
Published in Issue
Year 2020 Volume: 16 Number: 2
APA
Aras, S., Tanzer, İ. O., & İkizceli, T. (2020). Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy. Celal Bayar University Journal of Science, 16(2), 201-205. https://doi.org/10.18466/cbayarfbe.654782
AMA
1.Aras S, Tanzer İO, İkizceli T. Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy. CBUJOS. 2020;16(2):201-205. doi:10.18466/cbayarfbe.654782
Chicago
Aras, Serhat, İhsan Oguz Tanzer, and Türkan İkizceli. 2020. “Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy”. Celal Bayar University Journal of Science 16 (2): 201-5. https://doi.org/10.18466/cbayarfbe.654782.
EndNote
Aras S, Tanzer İO, İkizceli T (June 1, 2020) Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy. Celal Bayar University Journal of Science 16 2 201–205.
IEEE
[1]S. Aras, İ. O. Tanzer, and T. İkizceli, “Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy”, CBUJOS, vol. 16, no. 2, pp. 201–205, June 2020, doi: 10.18466/cbayarfbe.654782.
ISNAD
Aras, Serhat - Tanzer, İhsan Oguz - İkizceli, Türkan. “Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy”. Celal Bayar University Journal of Science 16/2 (June 1, 2020): 201-205. https://doi.org/10.18466/cbayarfbe.654782.
JAMA
1.Aras S, Tanzer İO, İkizceli T. Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy. CBUJOS. 2020;16:201–205.
MLA
Aras, Serhat, et al. “Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy”. Celal Bayar University Journal of Science, vol. 16, no. 2, June 2020, pp. 201-5, doi:10.18466/cbayarfbe.654782.
Vancouver
1.Serhat Aras, İhsan Oguz Tanzer, Türkan İkizceli. Comparison of Dose Distribution Effects for Various Bolus Materials in Electron Conformal Radiotherapy. CBUJOS. 2020 Jun. 1;16(2):201-5. doi:10.18466/cbayarfbe.654782