Time-Dependent Change of Color and Translucency of Recent Restorative Materials in Various Beverages
Year 2023,
, 150 - 158, 28.03.2023
Seda Nur Karakaş
,
Cihan Küden
Abstract
Objective: The aim of this study was to evaluate the time-dependent changes in optical properties of recent tooth-colored restorative materials in commonly used coloring beverages.
Method: A total of 200 specimens of four different materials (Alkasite, ACTIVA, Equia Forte, Zirconomer) and a composive material as the control group were prepared in Teflon molds and the materials were immersed in four different solutions (coffee, cola, ice tea and saliva) (n=10). Color measurements were performed with a spectrophotometer at baseline, 7, 14 and 28 days. Color changes, translucency parameters (TP) and contrast ratios of the materials were calculated. The data were analyzed by repeated measurements and three-way ANOVA and post hoc Tukey tests.
Results: Alkasite showed the greatest color change for all solutions in all immersion periods compared to other materials (p<0.001). The experimented solutions caused a perceptible color change in all materials after 28 days (p<0.05). Coffee and ice tea caused more staining of resin-based materials for all immersion periods (p<0.05). Initial TP and ∆TP of glass ionomer-based materials were found to be lower than the resin-based materials.
Conclusion: Exposure of the recent materials to different solutions for a certain period of time caused significant changes in optical properties. Resin-based alkasite, ACTIVA and composite showed the highest change the optical properties in coffee and ice tea.
Supporting Institution
Scientific Research Projects of Çukurova University
Project Number
TSA-2020-13339
References
- Ren Y-F, Feng L, Serban D, Malmstrom HS. Effects of common beverage colorants on color stability of dental composite resins: the utility of a thermocycling stain challenge model in vitro. J Dent. 2012;40:48-56.
- Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013;38:618-625.
- Tarle Z, Attin, T, Marovic D, Andermatt L, Ristic M, Tauböck TT. Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites. Clin Oral Investig 2015;19:831-840.
- Chau NPT, Pandit S, Cai JN, Lee M-H, Jeon J-G. Relationship between fluoride release rate and an-ti-cariogenic biofilm activity of glass ionomer cements. Dent Mater 2015;31:100-108.
- Hegde NN, Attavar SH, Hegde MN, Priya G. Antibacterial activity of dental restorative material: An in vitro study. J Conserv Dent 2018;21:42-46.
- Amalavathy RK, Sahoo HS, Shivanna S, Lingaraj J, Aravinthan S. Staining effect of various beverages on and surface nano-hardness of a resin coated and a non-coated fluoride releasing tooth-coloured re-storative material: An in-vitro study. Heliyon 2020;6:1-5.
- Karakaş SN, Küden C. Comparative Evaluation of Cavities Disinfected with Ozone Gas and Photodynamic Therapy and Restored with Two Different Reinforced Glass Ionomer Ce-ments on Microleakage and Color Change. Ozone Sci Eng 2021:1-10.
- Bhadra D, Shah NC, Rao AS, Dedania MS, Bajpai N. A 1-year comparative evaluation of clinical perfor-mance of nanohybrid composite with Activa™ bioactive composite in Class II carious lesion: A randomized control study. J Conserv Dent 2019;22:92-96.
- Atri F, Safi M, Salehzadeh S, Izadi J, Fallah PE, McLaren EA. Analysis of color and fluorescence of different dentin ceramics and natural human dentin's to enhance shade matching. J Esthet Dent 2021;33:1029-1034.
- Miletic V, Stasic JN, Komlenic V, Petrovic R. Multifactorial analysis of optical properties, sorption, and solubility of sculptable universal composites for enamel layering upon staining in colored beverages. J Esthet Dent 2021;33:943-952.
- Çakmak G, Donmez MB, Kashkari A, Johnston WM, Yılmaz B. Effect of thickness, cement shade, and coffee thermocycling on the optical properties of zirconia reinforced lithium silicate ceramic. J Esthet Dent 2021;1-7.
- Winter R. Visualizing the natural dentition. J Esthet Dent 1993;5:103-118.
- Uchimura JYT, Sato F, Santana RG, Menezes-Silva R, Bueono LS Borges AFS, Pascotto RC. Translucency parameter of conventional restora-tive glass‐ionomer cements. J Esthet Dent 2021;33:935-942.
- Barutçugil Ç, Bilgili D, Barutcigil K, Dündar A, Büyükkaplan UŞ, Yılmaz B. Discoloration and translucency changes of CAD-CAM materials after exposure to beverages. J Prosthet Dent 2019;122:325-331.
- Nogueira AD, Della Bona A. The effect of a coupling medium on color and translucency of CAD–CAM ceramics. J Dent 2013;41:18-23.
- Salas M, Lucena C, Herrera LJ, Yebra A, Della-Bona A, Perez MN. Translucency thresholds for dental materials. Dent Mater 2018;34:1168-1174.
- Blum IR, Özcan M. Reparative Dentistry: Possibilities and Limitations. Curr Oral Health Rep 2018;5:264-269.
- Villalta P, Lu H, Okte Z, Garcia-Godoy F, Powers JM. Effects of staining and bleaching on color change of dental composite resins. J Prosthet Dent 2006;95:137-142.
- Barutcigil Ç, Barutcigil K, Özarslan MM, Dündar A, Yılmaz B. Color of bulk‐fill composite resin restora-tive materials. J Esthet Dent 2018;30:3-8.
- Erdemir U, Yıldız E, Eren MM. Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion. J Dent 2012;40:55-63.
- Örtengren U, Andersson F, Elgh U, Terselius B, Karlsson S. Influence of pH and storage time on the sorption and solubility behaviour of three composite resin materials. J Dent 2001;29:35-41.
- Duke E, Trevino D. A resin-modified glass ionomer restorative: three-year clinical results. J Indiana Dent Assoc 1998;77:13-16.
- Abu‐Bakr NE, Han L, Okamoto A, Iwaku M. Color stability of compomer after immersion in various media. J Esthet Dent 2000;12:258-263.
- Johnston WM. Color measurement in dentistry J Dent 2009;37:2-6.
- Colorimetry C, Commission Internationale de l’Èclairage: Vienna. 2004, Austria.
- Luo MR, Cui G, Rigg B. The development of the CIE 2000 colour‐difference formula: CIEDE2000. Color Res Appl 2001;26:340-350.
- Kürklü D, Azer SS, Yilmaz B, Johnston WM. Porcelain thickness and cement shade effects on the colour and translucency of porcelain veneering materials. J Dent 2013;41:1043-1050.
- Watts A, Addy M. Tooth discolouration and staining: a review of the literature. Br Dent J 2001;190:309-316.
- Kim JH, Lee YK, Powers JM. Influence of a series of organic and chemical substances on the translucency of resin composites. J Biomed Mater Res B Appl Biomaters 2006;77:21-27.
- Gómez-Polo C, Muñoz MP, Luengo MC, Vicente P, Galindo P, Casado AMM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent 2016;115:65-70.
- Paravina RD, Ghin R, Herrera LJ, Bona AD, Igiel C, Lininger M, Mar-Perez MD. Color difference thresholds in dentistry. J Esthet Dent 2015;27:1-9.
- Samanta S, Das UK, Mitra A. Comparison of microleakage in class V cavity restored with flowable composite resin, glass ionomer cement and cention N. Imp J Interdiscip Res 2017;3:180-183.
- Croll TP, Berg JH, Donly KJ. Dental repair material: a resin-modified glass-ionomer bioac-tive ionic resin-based composite. Compend Contin Educ Dent 2015;36:60-5.
- Ertas E, Güler AU, Yücel AC, Köprülü H, Güler E. Color stability of resin composites after immersion in different drinks. Dent Mater J 2006;25:371-376.
- Barutcigil Ç, Yıldız M. Intrinsic and extrinsic discoloration of dimethacrylate and silorane based composites. J Dent 2012;40:57-63.
- Ardu S, Braut V, Gutemberg D, Krejci I, Dietschi D, Feilzer AJ. A long-term laboratory test on staining susceptibility of esthetic composite resin materials. Quintessence Int 2010;41:695-702.
- Fontes ST, Fernández MR, Moura CM, Meireles SS. Color stability of a nanofill compo-site: effect of different immersion media. J Appl Oral Sci 2009;17:388-391.
- Janda R, Roulet JF, Kaminsky M, Steffin G, Latta M. Color stability of resin matrix restorative materials as a function of the method of light activation. Eur J Oral Sci 2004;112:280-285.
- Krishnan VK, Yamuna V. Effect of initiator concentration, exposure time and particle size of the filler upon the mechanical properties of a light‐curing radiopaque dental composite. J Oral Rehabil 1998;25:747-751.
- Tekçe N, Tuncer S, Demirci M, Serim ME, Baydemir C. The effect of different drinks on the color stability of different restorative materials after one month. Restor Dent Endod 2015;40:255-261.
- Paravina RD, Ontiveros JC, Powers JM. Curing‐dependent changes in color and translu-cency parameter of composite bleach shades. J Esthet Dent 2002;14:158-166.
- Vichi A, Sedda M, Fabian-Fonzar R, Carrabba M, Ferrari M. Comparison of Contrast Ratio, Translucency Parameter, and Flexural Strength of Traditional and “Augmented Translucency” Zirconia for CEREC CAD/CAM System. J Esthet Dent 2016;28:32-39.
- Lee Y-K. Translucency of human teeth and dental restorative materials and its clinical rele-vance. J Biomed Opt 2015;20:045002.
- Hasegawa A, Ikeda I, Kawaguchi S. Color and translucency of in vivo natural central inci-sors. J Prosthet Dent 2000;83:418-423.
- Yu B, Ahn J-S, Lee Y-K. Measurement of translucency of tooth enamel and dentin. Ac-ta Odontol Scand 2009;67:57-64.
- Yu B, Lee Y-K. Differences in color, translucency and fluorescence between flowable and universal resin composites. J Dent 2008;36:840-846.
- Mount G, Patel C, Makinson O. Resin modified glass‐ionomers: Strength, cure depth and translucency. Aust Dent J 2002;47:339-343.
- Quek SH, Yap AU, Rosa V, Tan KBC, Teoh KHEffect of staining beverages on color and translucency of CAD/CAM composites. J Esthet Dent 2018;30:9-17.
- Stawarczyk B, Liebermann A, Eichberger M, Güth JF. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites. J Mech Behav Biomed Mater 2016;55:1-11.
Year 2023,
, 150 - 158, 28.03.2023
Seda Nur Karakaş
,
Cihan Küden
Project Number
TSA-2020-13339
References
- Ren Y-F, Feng L, Serban D, Malmstrom HS. Effects of common beverage colorants on color stability of dental composite resins: the utility of a thermocycling stain challenge model in vitro. J Dent. 2012;40:48-56.
- Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013;38:618-625.
- Tarle Z, Attin, T, Marovic D, Andermatt L, Ristic M, Tauböck TT. Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites. Clin Oral Investig 2015;19:831-840.
- Chau NPT, Pandit S, Cai JN, Lee M-H, Jeon J-G. Relationship between fluoride release rate and an-ti-cariogenic biofilm activity of glass ionomer cements. Dent Mater 2015;31:100-108.
- Hegde NN, Attavar SH, Hegde MN, Priya G. Antibacterial activity of dental restorative material: An in vitro study. J Conserv Dent 2018;21:42-46.
- Amalavathy RK, Sahoo HS, Shivanna S, Lingaraj J, Aravinthan S. Staining effect of various beverages on and surface nano-hardness of a resin coated and a non-coated fluoride releasing tooth-coloured re-storative material: An in-vitro study. Heliyon 2020;6:1-5.
- Karakaş SN, Küden C. Comparative Evaluation of Cavities Disinfected with Ozone Gas and Photodynamic Therapy and Restored with Two Different Reinforced Glass Ionomer Ce-ments on Microleakage and Color Change. Ozone Sci Eng 2021:1-10.
- Bhadra D, Shah NC, Rao AS, Dedania MS, Bajpai N. A 1-year comparative evaluation of clinical perfor-mance of nanohybrid composite with Activa™ bioactive composite in Class II carious lesion: A randomized control study. J Conserv Dent 2019;22:92-96.
- Atri F, Safi M, Salehzadeh S, Izadi J, Fallah PE, McLaren EA. Analysis of color and fluorescence of different dentin ceramics and natural human dentin's to enhance shade matching. J Esthet Dent 2021;33:1029-1034.
- Miletic V, Stasic JN, Komlenic V, Petrovic R. Multifactorial analysis of optical properties, sorption, and solubility of sculptable universal composites for enamel layering upon staining in colored beverages. J Esthet Dent 2021;33:943-952.
- Çakmak G, Donmez MB, Kashkari A, Johnston WM, Yılmaz B. Effect of thickness, cement shade, and coffee thermocycling on the optical properties of zirconia reinforced lithium silicate ceramic. J Esthet Dent 2021;1-7.
- Winter R. Visualizing the natural dentition. J Esthet Dent 1993;5:103-118.
- Uchimura JYT, Sato F, Santana RG, Menezes-Silva R, Bueono LS Borges AFS, Pascotto RC. Translucency parameter of conventional restora-tive glass‐ionomer cements. J Esthet Dent 2021;33:935-942.
- Barutçugil Ç, Bilgili D, Barutcigil K, Dündar A, Büyükkaplan UŞ, Yılmaz B. Discoloration and translucency changes of CAD-CAM materials after exposure to beverages. J Prosthet Dent 2019;122:325-331.
- Nogueira AD, Della Bona A. The effect of a coupling medium on color and translucency of CAD–CAM ceramics. J Dent 2013;41:18-23.
- Salas M, Lucena C, Herrera LJ, Yebra A, Della-Bona A, Perez MN. Translucency thresholds for dental materials. Dent Mater 2018;34:1168-1174.
- Blum IR, Özcan M. Reparative Dentistry: Possibilities and Limitations. Curr Oral Health Rep 2018;5:264-269.
- Villalta P, Lu H, Okte Z, Garcia-Godoy F, Powers JM. Effects of staining and bleaching on color change of dental composite resins. J Prosthet Dent 2006;95:137-142.
- Barutcigil Ç, Barutcigil K, Özarslan MM, Dündar A, Yılmaz B. Color of bulk‐fill composite resin restora-tive materials. J Esthet Dent 2018;30:3-8.
- Erdemir U, Yıldız E, Eren MM. Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion. J Dent 2012;40:55-63.
- Örtengren U, Andersson F, Elgh U, Terselius B, Karlsson S. Influence of pH and storage time on the sorption and solubility behaviour of three composite resin materials. J Dent 2001;29:35-41.
- Duke E, Trevino D. A resin-modified glass ionomer restorative: three-year clinical results. J Indiana Dent Assoc 1998;77:13-16.
- Abu‐Bakr NE, Han L, Okamoto A, Iwaku M. Color stability of compomer after immersion in various media. J Esthet Dent 2000;12:258-263.
- Johnston WM. Color measurement in dentistry J Dent 2009;37:2-6.
- Colorimetry C, Commission Internationale de l’Èclairage: Vienna. 2004, Austria.
- Luo MR, Cui G, Rigg B. The development of the CIE 2000 colour‐difference formula: CIEDE2000. Color Res Appl 2001;26:340-350.
- Kürklü D, Azer SS, Yilmaz B, Johnston WM. Porcelain thickness and cement shade effects on the colour and translucency of porcelain veneering materials. J Dent 2013;41:1043-1050.
- Watts A, Addy M. Tooth discolouration and staining: a review of the literature. Br Dent J 2001;190:309-316.
- Kim JH, Lee YK, Powers JM. Influence of a series of organic and chemical substances on the translucency of resin composites. J Biomed Mater Res B Appl Biomaters 2006;77:21-27.
- Gómez-Polo C, Muñoz MP, Luengo MC, Vicente P, Galindo P, Casado AMM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent 2016;115:65-70.
- Paravina RD, Ghin R, Herrera LJ, Bona AD, Igiel C, Lininger M, Mar-Perez MD. Color difference thresholds in dentistry. J Esthet Dent 2015;27:1-9.
- Samanta S, Das UK, Mitra A. Comparison of microleakage in class V cavity restored with flowable composite resin, glass ionomer cement and cention N. Imp J Interdiscip Res 2017;3:180-183.
- Croll TP, Berg JH, Donly KJ. Dental repair material: a resin-modified glass-ionomer bioac-tive ionic resin-based composite. Compend Contin Educ Dent 2015;36:60-5.
- Ertas E, Güler AU, Yücel AC, Köprülü H, Güler E. Color stability of resin composites after immersion in different drinks. Dent Mater J 2006;25:371-376.
- Barutcigil Ç, Yıldız M. Intrinsic and extrinsic discoloration of dimethacrylate and silorane based composites. J Dent 2012;40:57-63.
- Ardu S, Braut V, Gutemberg D, Krejci I, Dietschi D, Feilzer AJ. A long-term laboratory test on staining susceptibility of esthetic composite resin materials. Quintessence Int 2010;41:695-702.
- Fontes ST, Fernández MR, Moura CM, Meireles SS. Color stability of a nanofill compo-site: effect of different immersion media. J Appl Oral Sci 2009;17:388-391.
- Janda R, Roulet JF, Kaminsky M, Steffin G, Latta M. Color stability of resin matrix restorative materials as a function of the method of light activation. Eur J Oral Sci 2004;112:280-285.
- Krishnan VK, Yamuna V. Effect of initiator concentration, exposure time and particle size of the filler upon the mechanical properties of a light‐curing radiopaque dental composite. J Oral Rehabil 1998;25:747-751.
- Tekçe N, Tuncer S, Demirci M, Serim ME, Baydemir C. The effect of different drinks on the color stability of different restorative materials after one month. Restor Dent Endod 2015;40:255-261.
- Paravina RD, Ontiveros JC, Powers JM. Curing‐dependent changes in color and translu-cency parameter of composite bleach shades. J Esthet Dent 2002;14:158-166.
- Vichi A, Sedda M, Fabian-Fonzar R, Carrabba M, Ferrari M. Comparison of Contrast Ratio, Translucency Parameter, and Flexural Strength of Traditional and “Augmented Translucency” Zirconia for CEREC CAD/CAM System. J Esthet Dent 2016;28:32-39.
- Lee Y-K. Translucency of human teeth and dental restorative materials and its clinical rele-vance. J Biomed Opt 2015;20:045002.
- Hasegawa A, Ikeda I, Kawaguchi S. Color and translucency of in vivo natural central inci-sors. J Prosthet Dent 2000;83:418-423.
- Yu B, Ahn J-S, Lee Y-K. Measurement of translucency of tooth enamel and dentin. Ac-ta Odontol Scand 2009;67:57-64.
- Yu B, Lee Y-K. Differences in color, translucency and fluorescence between flowable and universal resin composites. J Dent 2008;36:840-846.
- Mount G, Patel C, Makinson O. Resin modified glass‐ionomers: Strength, cure depth and translucency. Aust Dent J 2002;47:339-343.
- Quek SH, Yap AU, Rosa V, Tan KBC, Teoh KHEffect of staining beverages on color and translucency of CAD/CAM composites. J Esthet Dent 2018;30:9-17.
- Stawarczyk B, Liebermann A, Eichberger M, Güth JF. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites. J Mech Behav Biomed Mater 2016;55:1-11.