BibTex RIS Cite

-

Year 2014, 2013 Doktora Programı Mezunları Özel Sayısı, 0 - , 13.05.2016

Abstract

Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures. Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p<0.05). Results: No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70.92(±40.02) µm for extended span length Y-TZP FPDs and 88.01(±54.34) µm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area (p<0.05). There was no significant difference in relation to span length. Conclusion: Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area

The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures

Year 2014, 2013 Doktora Programı Mezunları Özel Sayısı, 0 - , 13.05.2016

Abstract

Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures.
Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p<0.05). Results: No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70.92(±40.02) μm for extended span length Y-TZP FPDs and 88.01(±54.34) μm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area (p<0.05). There was no significant difference in relation to span length.

Conclusion: Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.

There are 0 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Senem Başbuğ Aydın, This is me

Deniz Gemalmaz This is me

Publication Date May 13, 2016
Submission Date October 1, 2015
Published in Issue Year 2014 2013 Doktora Programı Mezunları Özel Sayısı

Cite

APA Başbuğ Aydın, S., & Gemalmaz, D. (2016). The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences, 4.
AMA Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. May 2016;4.
Chicago Başbuğ Aydın, Senem, and Deniz Gemalmaz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences 4, May (May 2016).
EndNote Başbuğ Aydın, S, Gemalmaz D (May 1, 2016) The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences 4
IEEE S. Başbuğ Aydın, and D. Gemalmaz, “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”, Clinical and Experimental Health Sciences, vol. 4, 2016.
ISNAD Başbuğ Aydın,, Senem - Gemalmaz, Deniz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences 4 (May 2016).
JAMA Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. 2016;4.
MLA Başbuğ Aydın, Senem and Deniz Gemalmaz. “The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures”. Clinical and Experimental Health Sciences, vol. 4, 2016.
Vancouver Başbuğ Aydın, S, Gemalmaz D. The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures. Clinical and Experimental Health Sciences. 2016;4.

14639   14640