Conference Paper

Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy

Volume: 39 Number: 1 March 16, 2018
Cherif Kourtelı *, Fatima Benrachı
EN TR

Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy

Abstract

Flattening Filter Free (FFF) photon beams have been frequently used in radiotherapy clinical practice. This study aimed to analyze the dosimetric quality of the FFF beams, as compared to the standard flattened beams (FB) for plans of treatment of three patients involving three cancer sites using the 6 and 10 MV photon energies and the 3D conformal radiotherapy technique (3D-CRT). The doses to the planning target volumes (PTVs) and organs at risk (OARs) were compared. The dose-volume histogram curves analysis show that no significant differences between FFF and FB plans were found in the coverage and mean dose for the PTV, the OAR revealed slight differences. So the FFF photon beam achieved comparable dosimetric quality as the standard flat beam.

Keywords

Flattening Filter Free (FFF),3D conformal radiotherapy (3D-CRT),Treatment planning,Dosimetric evaluation

References

  1. [1]. Podgorsak E.B, Radiation Oncology Physics: A Handbook for Teachers and Students. International Atomic Energy Agency, 2005.
  2. [2]. Fogliata A & al, Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy, J. Med. Phys, 39 (2012) 6455- 64.
  3. [3]. Rout BK, Muralidhar KR, Ali M, Shekar MC and Kumar A, Dosimetric study of RapidArc plans with flattened beam (FB) and flattening filter-free (FFF) beam for localized prostate cancer based on physical indices. Int. J. Cancer Ther. Oncol., 2 (2014) 2046.
  4. [4]. M. Kretschmer & al, The impact of flattening-filter-free beam technology on 3D conformal RT, J. Radiat Oncol., 8 (2013) 133.
  5. [5]. Stathakis S and al, Treatment planning and delivery of IMRT using 6 and 18 MV photon beams without flattening filter. Applied Radiation and Isotopes, 67 (2009) 1629-37
  6. [6]. Mingzan Z and al, Volumetric modulation arc radiotherapy with flattening filter-free beams compared with conventional beams for nasopharyngeal carcinoma: a feasibility study, Chin. J. Cancer, 32 (2013) 397-402.
  7. [7]. Stevens S.W, Rosser K.E, and Bedford J.L, A 4 MV flattening filter free beam: Commissioning and application to conformal therapy and volumetric modulated arc therapy, J. Phys Med Biol., 56 (2011) 3809-24.
  8. [8]. Scorsetti M and al, Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments, J. Radiat Oncol., 6 (2011) 113.
  9. [9]. Vassiliev O.N and al, Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac, J. Appl Clin Med Phys., 10 ( 2009) 14–21.
  10. [10]. Georg D, Knöös T, McClean B, Current status and future perspective of flattening filter free photon beams, J. Med Phys., 38 (2011) 1280-93.
APA
Kourtelı, C., & Benrachı, F. (2018). Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. Cumhuriyet Science Journal, 39(1), 196-200. https://doi.org/10.17776/csj.359904
AMA
1.Kourtelı C, Benrachı F. Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. CSJ. 2018;39(1):196-200. doi:10.17776/csj.359904
Chicago
Kourtelı, Cherif, and Fatima Benrachı. 2018. “Evaluation of Dosimetric Impact of Flattening Filter-Free (FFF) Photon Beams in 3D Conformal Radiotherapy”. Cumhuriyet Science Journal 39 (1): 196-200. https://doi.org/10.17776/csj.359904.
EndNote
Kourtelı C, Benrachı F (March 1, 2018) Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. Cumhuriyet Science Journal 39 1 196–200.
IEEE
[1]C. Kourtelı and F. Benrachı, “Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy”, CSJ, vol. 39, no. 1, pp. 196–200, Mar. 2018, doi: 10.17776/csj.359904.
ISNAD
Kourtelı, Cherif - Benrachı, Fatima. “Evaluation of Dosimetric Impact of Flattening Filter-Free (FFF) Photon Beams in 3D Conformal Radiotherapy”. Cumhuriyet Science Journal 39/1 (March 1, 2018): 196-200. https://doi.org/10.17776/csj.359904.
JAMA
1.Kourtelı C, Benrachı F. Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. CSJ. 2018;39:196–200.
MLA
Kourtelı, Cherif, and Fatima Benrachı. “Evaluation of Dosimetric Impact of Flattening Filter-Free (FFF) Photon Beams in 3D Conformal Radiotherapy”. Cumhuriyet Science Journal, vol. 39, no. 1, Mar. 2018, pp. 196-00, doi:10.17776/csj.359904.
Vancouver
1.Cherif Kourtelı, Fatima Benrachı. Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. CSJ. 2018 Mar. 1;39(1):196-200. doi:10.17776/csj.359904