Artificial Learning Methods for Automatic Fault Detection in Electric Motors

Year 2017, Volume: 6 Issue: 2, 95 - 103, 01.07.2017

Abstract

Studies on the automatic detection of faults and diagnostics of electrical motors by training them in a classifier are becoming increasingly popular. In this study, using the signal characteristics which are effective in determining the faults of the electric motors and determining the fault severity, the effect of changing the characteristics of the motor in different load and speed conditions according to the severity of the fault is used as training and test data in the classification networks. Pattern recognition methods such as multi-layer artificial neural networks MLP , support vector machine SVM , k-nearest neighbors method kNN , decision tree DT and random forest RF methods and algorithms are explained In this study as well

References

  • C. Ortega, A. Arias, C. Caruana, J. Balcells, and G. M. Asher, “Improved waveform quality in the direct torque control of matrix-converter-fed PMSM drives,” IEEE Trans. Ind. Electron., vol. 57, no. 6, pp. 2101–2110, 2010.
  • J. Beerten, J. Verveckken, and J. Driesen, “Predictive Direct Torque Control for Flux and Torque Ripple Reduction,” IEEE Trans. Ind. Electron., vol. 57, no. 1, pp. 404–412, 2010.
  • R. Errouissi, M. . Ouhrouche, W.-H. . Chen, and A. M. Trzynadlowski, “Robust cascaded nonlinear predictive control of a permanent magnet synchronous motor with antiwindup compensator,” IEEE Trans. Ind. Electron., vol. 59, no. 8, pp. 3078–3088, 2012.
  • K. Raggl, B. Warberger, T. Nussbaumer, S. Burger, and J. W. Kolar, “Robust angle-sensorless control of a PMSM bearingless pump,” IEEE Trans. Ind. Electron., vol. 56, no. 6, pp. 2076–2085, 2009.
  • J. R. Riba Ruiz, J. A. Rosero, A. Garcia Espinosa, and L. Romeral, “Detection of demagnetization faults in permanent-Magnet synchronous motors under nonstationary conditions,” IEEE Trans. Magn., vol. 45, no. 7, pp. 2961–2969, 2009.
  • A. von Jouanne and B. Banerjee, “Assessment of voltage unbalance,” IEEE Trans. Power Deliv., vol. 16, no. 4, pp. 782–790, 2001.
  • S. Yu and R. Tang, “Electromagnetic and mechanical characterizations of noise and vibration in permanent magnet synchronous machines,” in IEEE Transactions on Magnetics, 2006, vol. 42, no. 4, pp. 1335–1338.
  • S. Ruoho, J. Kolehmainen, J. Ikaheimo, and A. Arkkio, “Interdependence of Demagnetization, Loading, and 29. J. Rosero, L. Romeral, E. Rosero, and J. Urresty, “Fault Temperature Rise in a Permanent-Magnet Synchronous Motor,” IEEE Trans. Magn., vol. 46, no. 3, pp. 949–953, Mar. 2010.
  • P. Zheng, J. Zhao, R. Liu, C. Tong, and Q. Wu, “Magnetic characteristics investigation of an axial-axial flux compound-structure PMSM used for HEVs,” in IEEE Transactions on Magnetics, 2010, vol. 46, no. 6, pp. 2191– 2194.
  • Z. Guoxin, T. Lijian, S. Qiping, and T. Renyuan, “Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault,” Power Energy Eng. Conf. (APPEEC), 2010 Asia-Pacific, pp. 1–4, 2010.
  • G. H. Kang, J. Hur, H. Nam, J. P. Hong, and G. T. Kim, “Analysis of irreversible magnet demagnetization in line- start motors based on the finite-element method,” IEEE Trans. Magn., vol. 39, no. 3 I, pp. 1488–1491, 2003.
  • S. Nandi, H. A. Toliyat, and X. Li, “Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review,” IEEE Trans. ENERGY Convers., vol. 20, no. 4, 2005.
  • B. M. Ebrahimi and J. Faiz, “Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity,” IET Electr. Power Appl., vol. 4, no. 1, pp. 53–65, 2010.
  • J. Hong, S. Bin Lee, C. Kral, and A. Haumer, “Detection of airgap eccentricity for permanent magnet synchronous motors based on the d-axis inductance,” IEEE Trans. Power Electron., vol. 27, no. 5, pp. 2605–2612, 2012. Detection in dynamic conditions by means of Discrete Wavelet Decomposition for PMSM running under Bearing Damage,” in 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition, 2009, pp. 951–956.
  • J. R. Stack, T. G. Habetler, and R. G. Harley, “Fault classification and fault signature production for rolling element bearings in electric machines,” in IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2003 - Proceedings, 2003, pp. 172–176.
  • J. R. Stack, R. G. Harley, and T. G. Habetler, “An amplitude Modulation detector for fault diagnosis in rolling element bearings,” IEEE Trans. Ind. Electron., vol. 51, no. 5, pp. 1097–1102, 2004.
  • J. C. Urresty Betancourt, “Electrical and magnetic faults diagnosis in permanent magnet synchronous motors.” Universitat Politècnica de Catalunya.
  • M. Arkan, H. Çaliş, and M. E. Tağluk, “Bearing and misalignment fault detection in induction motors by using the space vector angular fluctuation signal,” Electr. Eng., vol. 87, no. 4, pp. 197–206, 2005.

Elektrik Motorlarının Arıza Tespitinin Otomatik Olarak Yapılmasında Kullanılan Yapay Öğrenme Yöntemleri

Year 2017, Volume: 6 Issue: 2, 95 - 103, 01.07.2017

Abstract

Elektrik motorlarının arıza tespiti ve arıza tespitinde kullanılan özelliklerin bir sınıflandırıcıda eğitilerek arıza tespitinin otomatik olarak yapılması üzerine yapılan çalışmalar gittikçe popüler hale gelmektedir. Bu çalışmada elektrik motorlarının arızalarının tespiti ve arıza şiddetinin belirlenmesinde etkin olan sinyal özellikleri kullanılarak motorun farklı yük ve hız durumlarında karakteristik özelliklerinin arıza şiddetine göre değişim miktarı sınıflandırıcı ağlarda eğitim ve test verileri olarak kullanılması, sınıflandırmanın başarısında etkili olmaktadır. Bu çalışmada arıza tespitinin otomatik olarak belirlenmesi amacıyla kullanılan çok katmanlı yapay sinir ağları MLP , destek vektör makinası SVM , k-en yakın komşuluk yöntemi kNN , karar ağacı DT ve Random Forest RF gibi örüntü tanıma ÖT yöntem ve algoritmaları anlatılmaktadır

References

  • C. Ortega, A. Arias, C. Caruana, J. Balcells, and G. M. Asher, “Improved waveform quality in the direct torque control of matrix-converter-fed PMSM drives,” IEEE Trans. Ind. Electron., vol. 57, no. 6, pp. 2101–2110, 2010.
  • J. Beerten, J. Verveckken, and J. Driesen, “Predictive Direct Torque Control for Flux and Torque Ripple Reduction,” IEEE Trans. Ind. Electron., vol. 57, no. 1, pp. 404–412, 2010.
  • R. Errouissi, M. . Ouhrouche, W.-H. . Chen, and A. M. Trzynadlowski, “Robust cascaded nonlinear predictive control of a permanent magnet synchronous motor with antiwindup compensator,” IEEE Trans. Ind. Electron., vol. 59, no. 8, pp. 3078–3088, 2012.
  • K. Raggl, B. Warberger, T. Nussbaumer, S. Burger, and J. W. Kolar, “Robust angle-sensorless control of a PMSM bearingless pump,” IEEE Trans. Ind. Electron., vol. 56, no. 6, pp. 2076–2085, 2009.
  • J. R. Riba Ruiz, J. A. Rosero, A. Garcia Espinosa, and L. Romeral, “Detection of demagnetization faults in permanent-Magnet synchronous motors under nonstationary conditions,” IEEE Trans. Magn., vol. 45, no. 7, pp. 2961–2969, 2009.
  • A. von Jouanne and B. Banerjee, “Assessment of voltage unbalance,” IEEE Trans. Power Deliv., vol. 16, no. 4, pp. 782–790, 2001.
  • S. Yu and R. Tang, “Electromagnetic and mechanical characterizations of noise and vibration in permanent magnet synchronous machines,” in IEEE Transactions on Magnetics, 2006, vol. 42, no. 4, pp. 1335–1338.
  • S. Ruoho, J. Kolehmainen, J. Ikaheimo, and A. Arkkio, “Interdependence of Demagnetization, Loading, and 29. J. Rosero, L. Romeral, E. Rosero, and J. Urresty, “Fault Temperature Rise in a Permanent-Magnet Synchronous Motor,” IEEE Trans. Magn., vol. 46, no. 3, pp. 949–953, Mar. 2010.
  • P. Zheng, J. Zhao, R. Liu, C. Tong, and Q. Wu, “Magnetic characteristics investigation of an axial-axial flux compound-structure PMSM used for HEVs,” in IEEE Transactions on Magnetics, 2010, vol. 46, no. 6, pp. 2191– 2194.
  • Z. Guoxin, T. Lijian, S. Qiping, and T. Renyuan, “Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault,” Power Energy Eng. Conf. (APPEEC), 2010 Asia-Pacific, pp. 1–4, 2010.
  • G. H. Kang, J. Hur, H. Nam, J. P. Hong, and G. T. Kim, “Analysis of irreversible magnet demagnetization in line- start motors based on the finite-element method,” IEEE Trans. Magn., vol. 39, no. 3 I, pp. 1488–1491, 2003.
  • S. Nandi, H. A. Toliyat, and X. Li, “Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review,” IEEE Trans. ENERGY Convers., vol. 20, no. 4, 2005.
  • B. M. Ebrahimi and J. Faiz, “Diagnosis and performance analysis of three-phase permanent magnet synchronous motors with static, dynamic and mixed eccentricity,” IET Electr. Power Appl., vol. 4, no. 1, pp. 53–65, 2010.
  • J. Hong, S. Bin Lee, C. Kral, and A. Haumer, “Detection of airgap eccentricity for permanent magnet synchronous motors based on the d-axis inductance,” IEEE Trans. Power Electron., vol. 27, no. 5, pp. 2605–2612, 2012. Detection in dynamic conditions by means of Discrete Wavelet Decomposition for PMSM running under Bearing Damage,” in 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition, 2009, pp. 951–956.
  • J. R. Stack, T. G. Habetler, and R. G. Harley, “Fault classification and fault signature production for rolling element bearings in electric machines,” in IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2003 - Proceedings, 2003, pp. 172–176.
  • J. R. Stack, R. G. Harley, and T. G. Habetler, “An amplitude Modulation detector for fault diagnosis in rolling element bearings,” IEEE Trans. Ind. Electron., vol. 51, no. 5, pp. 1097–1102, 2004.
  • J. C. Urresty Betancourt, “Electrical and magnetic faults diagnosis in permanent magnet synchronous motors.” Universitat Politècnica de Catalunya.
  • M. Arkan, H. Çaliş, and M. E. Tağluk, “Bearing and misalignment fault detection in induction motors by using the space vector angular fluctuation signal,” Electr. Eng., vol. 87, no. 4, pp. 197–206, 2005.
There are 18 citations in total.

Details

Primary Language Turkish
Journal Section Research Article
Authors

Ferhat Çıra This is me

Publication Date July 1, 2017
Published in Issue Year 2017 Volume: 6 Issue: 2

Cite

IEEE F. Çıra, “Elektrik Motorlarının Arıza Tespitinin Otomatik Olarak Yapılmasında Kullanılan Yapay Öğrenme Yöntemleri”, DUFED, vol. 6, no. 2, pp. 95–103, 2017.


DUFED is indexed/abstracted/enlisted in

Google Scholar | CABI - CAB Abstracts and Global Health | CAS Chemical Abstracts Service | ROAD Directory of Open Access Scholarly Resources | Index Copernicus | CiteFactor Academic Scientific Journals | BASE Bielefeld Academic Search Engine | Open AIRE | IJIFACTOR | ASOS Index | Paperity Open Science Aggregated | I2OR International Institute of Organized Research | SJIF Scientific Journal Impact Factor | Advanced Science Index | DRJI Directory of Research Journals Indexing | SOBİAD | AcarIndex | SIS Scientific Indexing Services | Crossref | Harman Türkiye Akademik Arşivi | AccessOn | Dimensions | Wizdom | OUCI The Open Ukrainian Citation Index | WorldCat | Scilit | ASCI Asian Science Citation Index

  cc.logo.large.png       Creative Commons License

28576
DUFED is a diamond open-access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles, or use them for any other lawful purpose, without asking prior permission from the publisher or the author. This is in accordance with the BOAI definition of open access. In addition, authors are not charged article processing fees or publication fees - no fees whatsoever. Importantly, authors retain the copyright of their work and allow it to be shared and reused, provided that it is correctly cited.

1024px-DOI_logo.svg.png https://doi.org/10.55007/dufed.xxxxxxx