Paracetamol (Par) is a widely consumed antipyretic and analgesic drug. Its global use to reduce or prevent fever is increasing day by day, especially after the pandemic era. It has been detected in natural water resources and has emerged as a potential water contaminant.Therefore, the development of miniaturized detection platforms for the detection of Par has become an attractive topic. Herein, a disposable pencil graphite electrode (PGE) was used in combination with the differential pulse voltammetry (DPV) technique for the detection of Par. A passive adsorption strategy was implemented for the immobilization of Par molecules prepared in phosphate buffer solution (PBS, pH 7.40) on the PGE surface. Then, voltammetric measurements were performed. The experimental parameters were optimized according to the changes in the Par oxidation signal observed at +0.325V. The limit of detection (LOD) and limit of quantification (LOQ) values were calculated as 7.06 µg/mL and 23.56 µg/mL, respectively, in the linear concentration range as 10-40 µg/mL using electrochemically pre-treated PGEs and a 30 min immobilization time. Finally, the greenness level of the proposed method was calculated as 0.77 using Analytical GREEnness Metric Approach and Software (AGREE). The voltammetric detection of Par could be performed using just 100 µL Par sample for < 30 s.
Analytical GREEnness Metric Approach and Software (AGREE) Differential pulse voltammetry (DPV) paracetamol pencil graphite electrodes (PGEs)
| Primary Language | English |
|---|---|
| Subjects | Analytical Chemistry (Other) |
| Journal Section | Research Article |
| Authors | |
| Submission Date | June 9, 2025 |
| Acceptance Date | August 18, 2025 |
| Early Pub Date | October 23, 2025 |
| Publication Date | December 31, 2025 |
| DOI | https://doi.org/10.55971/EJLS.1716168 |
| IZ | https://izlik.org/JA78ST35YU |
| Published in Issue | Year 2025 Volume: 4 Issue: 3 |
Announcement
Dear Readers, Authors, and Reviewers,
An inconsistency has been identified in the automatically generated editorial board information due to a technical issue in the infrastructure that enables the electronic management of our journal. As a result of this technical problem, the current editorial board information can be accessed on DergiPark at https://dergipark.org.tr/en/pub/ejls/board.
However, the editorial board and reviewer information for a published issue are included in the PDF file of the relevant issue. Therefore, the accurate and authoritative information should be accessed through the PDF of the respective issue.
For your information.
**Click here for an important announcement regarding the Editorial Board.**