Research Article

Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study

Volume: 54 Number: 1 January 23, 2020
  • Seval Bayrak *
  • Emine Sebnem Kursun Cakmak
  • Hakan Kamalak
EN

Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study

Abstract

Purpose In radiological views, strong beam hardening and streaking artifacts occur due to high-density structures and polyenergetic X-ray beams, and these lead to misdiagnosis. This study was performed in vitro to compare the contrast-to-noise ratio (CNR) of commonly used dental restorative materials by using Cone Beam Computed Tomography (CBCT) images with and without artifact reduction (AR) mode. Materials and Methods A total of 108 molar teeth were restored with nine different groups of restorative materials, with each group containing 12 teeth. Teeth were placed in a dry human mandible and scanned, one by one, via Planmeca 3D ProMax (Planmeca, Helsinki, Finland) with and without AR mode. Images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the CNR. Results CNR was calculated to be the highest in compomer (Glassiosite) images without AR mode (mean: 3.36) and with AR mode (mean: 3.61). CNR was calculated to be the lowest in amalgam (Tytin) images without AR mode (mean: 0.21) and with AR mode (mean: 0.23). A significant difference was found between materials in terms of CNR measurements (p ≤ 0.05). CNR measurements were increased after the AR mode application (p ≤ 0.05). Conclusion AR mode was effective in reducing artifacts arising from dental materials on CBCT images, so it is necessary to use AR mode for correct diagnoses.

Keywords

Supporting Institution

The authors declared that this study has received no financial support.

References

  1. 1. Scarfe WC, Li Z, Aboelmaaty W, Scott SA, Farman AG. Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation. Aust Dent J 2012;57(Suppl 1):46-60. [CrossRef]
  2. 2. Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am 2008;52(4):707-30. [CrossRef]
  3. 3. Pauwels R, Silkosessak O, Jacobs R, Bogaerts R, Bosmans H, Panmekiate S. A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose. Dentomaxillofac Radiol 2014;43(5):20140059. [CrossRef]
  4. 4. Panjnoush M, Kheirandish Y, Kashani PM, Fakhar HB, Younesi F, Mallahi M. Effect of Exposure Parameters on Metal Artifacts in Cone Beam Computed Tomography. J Dent (Tehran) 2016;13(3):143-50.
  5. 5. Kim MS, Kim BY, Choi HY, Choi YJ, Oh SH, Kang JH, et al. Intravenous contrast media application using cone-beam computed tomography in a rabbit model. Imaging Sci Dent 2015;45(1):31-9. [CrossRef]
  6. 6. Queiroz PM, Oliveira ML, Groppo FC, Haiter-Neto F, Freitas DQ. Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials. Clin Oral Investig 2018;22(1):419-23. [CrossRef]
  7. 7. Taylor C. Evaluation of the effects of positioning and configuration on contrast-to-noise ratio in the quality control of a 3D Accuitomo 170 dental CBCT system. Dentomaxillofac Radiol 2016;45(5):20150430. [CrossRef]
  8. 8. Cebe F, Aktan AM, Ozsevik AS, Ciftci ME, Surmelioglu HD. The effects of different restorative materials on the detection of approximal caries in cone-beam computed tomography scans with and without metal artifact reduction mode. Oral Surg Oral Med Oral Pathol Oral Radiol 2017;123(3):392-400. [CrossRef]

Details

Primary Language

English

Subjects

Dentistry, Health Care Administration

Journal Section

Research Article

Authors

Seval Bayrak * This is me
Türkiye

Emine Sebnem Kursun Cakmak This is me
0000-0002-7113-5450
Türkiye

Hakan Kamalak This is me
0000-0002-1497-2009
Türkiye

Publication Date

January 23, 2020

Submission Date

November 28, 2018

Acceptance Date

May 28, 2019

Published in Issue

Year 2020 Volume: 54 Number: 1

APA
Bayrak, S., Kursun Cakmak, E. S., & Kamalak, H. (2020). Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study. European Oral Research, 54(1), 36-41. https://doi.org/10.26650/eor.20200079
AMA
1.Bayrak S, Kursun Cakmak ES, Kamalak H. Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study. EOR. 2020;54(1):36-41. doi:10.26650/eor.20200079
Chicago
Bayrak, Seval, Emine Sebnem Kursun Cakmak, and Hakan Kamalak. 2020. “Contrast-to-Noise Ratios of Different Dental Restorative Materials: An In-Vitro Cone Beam Computed Tomography Study”. European Oral Research 54 (1): 36-41. https://doi.org/10.26650/eor.20200079.
EndNote
Bayrak S, Kursun Cakmak ES, Kamalak H (January 1, 2020) Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study. European Oral Research 54 1 36–41.
IEEE
[1]S. Bayrak, E. S. Kursun Cakmak, and H. Kamalak, “Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study”, EOR, vol. 54, no. 1, pp. 36–41, Jan. 2020, doi: 10.26650/eor.20200079.
ISNAD
Bayrak, Seval - Kursun Cakmak, Emine Sebnem - Kamalak, Hakan. “Contrast-to-Noise Ratios of Different Dental Restorative Materials: An In-Vitro Cone Beam Computed Tomography Study”. European Oral Research 54/1 (January 1, 2020): 36-41. https://doi.org/10.26650/eor.20200079.
JAMA
1.Bayrak S, Kursun Cakmak ES, Kamalak H. Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study. EOR. 2020;54:36–41.
MLA
Bayrak, Seval, et al. “Contrast-to-Noise Ratios of Different Dental Restorative Materials: An In-Vitro Cone Beam Computed Tomography Study”. European Oral Research, vol. 54, no. 1, Jan. 2020, pp. 36-41, doi:10.26650/eor.20200079.
Vancouver
1.Seval Bayrak, Emine Sebnem Kursun Cakmak, Hakan Kamalak. Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study. EOR. 2020 Jan. 1;54(1):36-41. doi:10.26650/eor.20200079