Conference Paper

A Study of U-Shaped Optical Fiber Sensor for Sensing Different Concentrations of Glucose and Ion liquid (HgCl2) and a Fabrication of Microfluidics System

Volume: 22 September 1, 2023
  • Tien Bao Tran
  • Hsiang Cheng Hsu
  • Chia Chin Chıang
EN

A Study of U-Shaped Optical Fiber Sensor for Sensing Different Concentrations of Glucose and Ion liquid (HgCl2) and a Fabrication of Microfluidics System

Abstract

In this study, we demonstrate the sensitivity of U-shaped with the different resolutions of Glucose and Mercury Chloride (HgCl2). We also indicate the process of fabricating a Microfluidics system by using CO2 laser with Poly Methyl Methacrylate (PMMA) as material. According to the experiments, the sensor can be used to evaluate the concentrations of Glucose and HgCl2. While the shift of resonance wavelength raised with the increase of Glucose Concentration from 5% to 50% with R2=0.95, there is a fluctuation in the shift of resonance wavelength with HgCl2 Concentration from 5 ppm to 50 ppm. Especially with transmission loss, Glucose, and HgCl2 witness the same phenomenon when the transmission loss goes up simultaneously with the increase of concentration, with R2=0.86 for Glucose and R2=0.78 for HgCl2. Finally, we manufacture successfully the Microfluidics system with the dimensions including depth: 0.3 mm and width: 0.2 mm. By mixing Glucose 0% and 50%, it leads to the conclusion that the Microfluidics system works appropriately.

Keywords

References

  1. Castillo Leon, J., &.Svendsen, W.E. (2015). Lab-on-a-chip devices and micro-total analysis system. Cham: Springer.
  2. Krohn, D.A., MacDougall., & Mendez, A. (2014). Fiber optic sensors: Fundamentals and applications (4th ed.). USA: SPIE.
  3. Miller, S.E., Chynoweth, A.G., & Kami, I. P. (1979). Optical fiber telecommunication (1 st ed). Frederick, USA: Academic Press.
  4. Park, S.J., Ta, C.L., Baek, H.G., Kim, Y.H., Eom, J.B., Lee, Y.T., & Lee, B.H. (2013). Optical fiber sensor for refractive index measurement based on localized surface plasmon resonance. Conference on Lasers and Electro-Optics Pacific Rim. Kyoto Japan
  5. Renner, H. (1992). Bending losses of coated single-mode fibers: A simple approach. Journal of Lightwave Technology, 10(5), 544-551.
  6. Ribeiro, L. A., Rosolem, J. B., Dini, D. C., Floridia, C., Bezerra, E. W., Cezar, F. A., ... & Durelli, A. S. (2012, May). Optical fiber sensor for pressure measurement based on elastomeric membrane and macrobending loss. In Optical Sensing and Detection II (Vol. 8439, pp. 110-118). SPIE.
  7. Roriz, P. Silva, S., Frazao, O., & Novais, S. (2020). Optical fiber temperature sensor and their biomedical application. Sensors,20(7),2113.
  8. Tan, A. J.Y., Ng, S.M., Stoddart, P.R., & Chua, H.S. (2021). Trends and application of u-shaped fiber optic sensors: A review. IEEE Sensors Journal, 21(1), 120-131.

Details

Primary Language

English

Subjects

Chemical Engineering Design

Journal Section

Conference Paper

Authors

Tien Bao Tran This is me
Taiwan

Hsiang Cheng Hsu This is me
Taiwan

Chia Chin Chıang This is me
Taiwan

Early Pub Date

August 6, 2023

Publication Date

September 1, 2023

Submission Date

June 21, 2023

Acceptance Date

July 20, 2023

Published in Issue

Year 2023 Volume: 22

APA
Tran, T. B., Hsu, H. C., & Chıang, C. C. (2023). A Study of U-Shaped Optical Fiber Sensor for Sensing Different Concentrations of Glucose and Ion liquid (HgCl2) and a Fabrication of Microfluidics System. The Eurasia Proceedings of Science Technology Engineering and Mathematics, 22, 127-134. https://doi.org/10.55549/epstem.1338557