Conference Paper

Examining the Performance of the Heat Exchanger in a Heat Pump Clothes Dryer

Volume: 26 December 30, 2023
  • Fazil Erinc Yavuz
  • Vasif Can Yıldıran
  • Sebastian George Colleonı
EN

Examining the Performance of the Heat Exchanger in a Heat Pump Clothes Dryer

Abstract

The performance of the newly designed fin and tube heat exchanger placed within the heat pump tumble dryer (HPTD) has been numerically and experimentally investigated. A new heat exchanger (HX) has one inlet and one outlet for the refrigerant side. However, after insertion into the evaporator, the flow splits into two different branches and reaches a lower pressure than the standard one. Also, due to the separation more tube bundles can be fitted in the same amount of volume. Due to increased tube bundles, total heat transfer is increased. This behavior can be seen with numerical and experimental results. Also, the fin structures on the heat exchanger were removed from the model to avoid increasing the solution grid density. In this region, it was defined as a porous structure to accommodate the pressure drop. To solve the problem, the program called ANSYS-FLUENT was utilized to solve the problem, and the PISO algorithm was employed to solve the pressure-velocity pair. While air at a specified temperature was passed around the exchanger, water was circulated on the inner surface instead of the refrigerant gas to observe the temperature change.

Keywords

References

  1. Lee, K. S., Jhee, S., & Yang, D. K. (2003). Prediction of the frost formation on a cold flat surface. International Journal of Heat and Mass Transfer, 46(20), 3789-3796.
  2. Lenic, K., Trp, A., & Frankovic, B. (2009). Transient two-dimensional model of frost formation on a fin-and-tube heat exchanger. International Journal of Heat and Mass Transfer, 52(1-2), 22-32.
  3. Liu, J., Wei, W., Ding, G., Zhang, C., Fukaya, M., Wang, K., & Inagaki, T. (2004). A general steady state mathematical model for fin-and-tube heat exchanger based on graph theory. International Journal of Refrigeration, 27(8), 965-973.
  4. Lu, C. W., Huang, J. M., Nien, W. C., & Wang, C. C. (2011). A numerical investigation of the geometric effects on the performance of plate finned-tube heat exchanger. Energy Conversion and Management, 52(3), 1638-1643.

Details

Primary Language

English

Subjects

Environmental and Sustainable Processes

Journal Section

Conference Paper

Authors

Fazil Erinc Yavuz This is me
Türkiye

Vasif Can Yıldıran This is me
Türkiye

Sebastian George Colleonı This is me
Italy

Early Pub Date

December 25, 2023

Publication Date

December 30, 2023

Submission Date

July 9, 2023

Acceptance Date

November 30, 2023

Published in Issue

Year 2023 Volume: 26

APA