Research Article

OPTIMUM CFRP LENGTH FOR THE HOGGING MOMENT ZONE (HMZ) OF CONTINUOUS RC T-BEAMS

Number: 1 November 9, 2017
  • Mohammad Mohie Eldin
  • Ahmed M. Tarabia
  • Rahma F. Hasson
EN

OPTIMUM CFRP LENGTH FOR THE HOGGING MOMENT ZONE (HMZ) OF CONTINUOUS RC T-BEAMS

Abstract

Carbon fiber reinforced polymer (CFRP) laminates were proved as very effective method for either repairing or strengthening of used structures. However, the literature has no enough information about the behavior of RC continuous (two-span) T-section beams strengthened with CFRP laminates, especially in hogging moment zone (HMZ). This paper examines the effect of CFRP laminates lengths, used for strengthening of the hogging moment zone, upon the behavior of such beams, to determine the optimum strengthening length. 3-D theoretical models using the Finite Element (FE) Package ANSYS are used. The paper contains the main details of the FE modeling process; used element types, material properties, meshing, yield criterion and boundary conditions. The results of the proposed FE model were compared with those of a previous experimental research and very good agreement was found between both FE and experimental results. Three parameters were used in the parametric study; CFRP length, CFRP thickness, percentage ratio of the steel reinforcement (different diameters for reinforcement steel bars). To examine the effect of changing CFRP strengthening lengths, different types of results for the proposed parametric study were obtained for better understanding of behavior. Adding to this, these results were compared and analyzed at different stages of loading between first cracking of the RC studied T-beams and their failure. These results include load-deflection curves, bending moment diagrams, stresses and strains of the CFRP laminates, stresses and strains of steel reinforcement bars, redistribution of moments, energy dissipation, ductility, shear (bond) stresses and failure modes of the studied beams. It can be concluded that changing CFRP length in the HMZ is very effective upon the overall behavior of T-section continuous RC beams. This effect begins after first crack and considered as effective after the yielding of upper steel bars. Increasing the lengths of CFRP laminates increases capacity, ductility and energy dissipation of strengthened beams in the hogging moment zone. Also, it improves utilizing of upper steel bars and redistribution of moments between sagging and hogging moments. Practically, Design-Codes of using CFRP in strengthening of structures concern only with both CFRP strengthening length and its corresponding anchorage length. As a result, definitions of both optimum CFRP strengthening length and CFRP anchorage length were expressed. Finally, criteria to calculate both of them were concluded

Keywords

References

  1. El-Mogy M., El-Ragaby A., and El-Salakawy E.: Experimental testing and finite element modeling on continuous concrete beams reinforced with fibre reinforced polymer bars and stirrups. Canadian Journal of Civil Engineering, 40 (11), 1091–1102, November, (2013). El-Refaie S. A., Ashour A. F. and Garrity S. W.: Sagging and Hogging Strengthening of Continuous Reinforced Concrete Beams Using Carbon Fiber-Reinforced Polymer Laminates. ACI Structural Journal, 100 (4), 446-453, July-August, (2003). Maghsoudi A. A. and Bengar H. A.: Moment redistribution and ductility of RHSC continuous beams strengthened with CFRP. Turkish Journal of Engineering and Environmental Sciences (http://journals.tubitak.gov.tr/engineering/issues/muh-09-33-1/muh-33-1-5-0901-6.pdf), 33, 45-59, (2009). Saleh A. R. and Barem A. A. H.: Experimental and Theoretical Analysis for Behavior of R.C. Continuous Beams Strengthened by CFRP Laminates. Journal of Babylon University (Iraq) - Engineering Sciences, 21 (5), 1555-1567, (2013). Saribiyik A. and Caglar N.: Flexural strengthening of RC Beams with low-strength concrete using GFRP and CFRP. Journal of Structural Engineering and Mechanics, 58 (5), 825-845, June, (2016). Rahman M. M. and Rahman M. W.: Simplified method of strengthening RC continuous T beam in the hogging zone using carbon fiber reinforced polymer laminate - A numerical investigation. Journal of Civil Engineering Construction Technology (http://www.academicjournals.org/JECET), 4 (6), 174-183, June, (2013). Iesa W. M., Alferjani M. B. S., Ali N. and AbdulSamad A. A.: Study on Shear Strengthening of RC Continuous Beams with Different CFRP Wrapping Schemes. International Journal of Integrated Engineering (Issue on Civil and Environmental Engineering) (http://penerbit.uthm.edu.my/ojs/index.php/ijie/article/view/207), 2 (2), 35-43, (2010). Lu X. Z., Ten J. G., Ye L. P., Jaing J. J.: Bond-slip models for FRP sheets/plates bonded to concrete. Journal of Engineering Structures, 24 (5), 920-937, (2005). Aiello M. A. and Ombre, L.: Moment Redistribution in Continuous Fiber-Reinforced Polymer-strengthened Reinforced Concrete Beams. ACI Structural Journal, 158-166, March-April, (2011). In press article: Mohie Eldin M, Tarabia A. M. and Hasson R. F.: CFRP Strengthening of Continuous RC T-Beams at Hogging Moment Zone across the Flange. Accepted in Journal of Structural Engineering and Mechanics, Techno-press, 2018 (In Press). Tarabia A. M., Mohie Eldin M and Hasson R. F.: Failure Modes of Continuous Reinforced Concrete T-Beams Strengthened Using CFRP Laminates. Accepted in ‘Proceeding of the International Conference on Advances in Civil, Structural and Mechanical Engineering, Antalya, Turkey', October, 2017 (In press). Shrestha U. S.: Modified Composite Application to Improve Strength and Ductility of Structural Components. MSc Dissertation, College of Graduate Studies, The University of Toledo, Ohio, United States, (2014). ANSYS: ANSYS Help. Release 15 (2013). Taerwe L., Vasseur L. and Matthys S.: External strengthening of continuous beams with CFRP. in ‘Concrete Repair, Rehabilitation and Retrofitting II’ Alexander et al (eds),Taylor & Francis Group, ISBN 978-0-415-46850-3, London, 43-53, (2009). Thorenfeldt E., Tomaszewicz A. and Jensen J.: Mechanical Properties of High Strength Concrete and Application to Design. in ‘Proceedings of the Symposium: Utilization of High-Strength Concrete, Stavanger, Norway’, 149–159, June, (1987). Sakr M. A., Khalifa T. M. and Mansour W. N.: External Strengthening of RC Continuous Beams Using FRP Plates: Finite Element Model. In ‘Proceeding of the Second International Conference on Advances in Civil, Structural and Mechanical Engineering- CSM 2014’, ISBN: 978-1-63248-054-5, 168-174, (2014). ECP-203: Egyptian Code of Practice for the Design and Implementation of Reinforced Concrete Structures (2007). ECP-208: Egyptian Code for the Design Principals and Implementation Requirements of Using CFRP in Fields of Construction (2005).

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Mohammad Mohie Eldin This is me

Ahmed M. Tarabia This is me

Rahma F. Hasson This is me

Publication Date

November 9, 2017

Submission Date

December 10, 2017

Acceptance Date

-

Published in Issue

Year 2017 Number: 1

APA
Eldin, M. M., Tarabia, A. M., & Hasson, R. F. (2017). OPTIMUM CFRP LENGTH FOR THE HOGGING MOMENT ZONE (HMZ) OF CONTINUOUS RC T-BEAMS. The Eurasia Proceedings of Science Technology Engineering and Mathematics, 1, 158-177. https://izlik.org/JA84PF96PK