Research Article

Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View

Volume: 7 Number: 1 April 30, 2023
EN TR

Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View

Abstract

ABSTRACT Objectives: Various artifacts can be encountered when examining Cone-beam computed tomography(CBCT) images. In recent years, no descriptive study has been conducted on CBCT artifacts in the literature. The aim of this study is to identify artifacts in CBCT images with different imaging fields (FOV) taken on the same device, to determine their frequency, and also to reveal artifacts that are little known in the literature. Materials and Methods: In the study, CBCT images of the Faculty of Dentistry between the years 2012-2021 were scanned retrospectively and a total of 359 Cone Beam Computed Tomography images with 50x55, 100x55, 100x90, 130x55, 130x90, 230x170, 230x270 imaging fields (FOV) in the database, which met the exclusion and inclusion criteria, were analyzed by three oral and maxillofacial radiology research assistants and the types of artifacts seen on these images were determined. The incidence of the identified artifact types in the specified imaging areas was evaluated. Results: When looking at all images, the most common errors, regardless of FOV, were inevitable artifacts. Aliasing and motion artifacts were seen at higher rates on CBCT images with a larger field of view. In addition, the ring artifact was encountered in CBCT images with high imaging fields such as 130x90, 230x170 and 230x270. Conclusion: To know the incidence and causes of artifacts in images; it will prevent the patient, the environment and the practitioner from receiving x-rays (radiation) unnecessarily, mixing these errors with different pathological conditions and repetition of the image.

Keywords

References

  1. Referans1 Terakado M, Hashimoto K, Arai Y, Honda M, Sekiwa T, Sato H.Diagnostic imaging with newly developed ortho cubic super-high resolution computed tomography (Ortho-CT). Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics 2000; 89(4), 509–518.
  2. Referans2 Arai Y, Tammisalo E, Iwai K. Development of a compact computed tomographic apparatus for dental use. Dentomaxillofac Radiol 1999; 28: pp. 245-248.
  3. Referans3 Scarfe WC, Farman AG.What is cone-beam CT and how does it work?. Dent Clin North Am 2008; 52: pp. 707-730.
  4. Referans4 Pauwels R. What is CBCT and how does itwork?. In: Scarfe WC, Angelopoulos C, eds. Maxillofacial Cone Beam Computed Tomography: Principles, Techniques and Clinical Applications. 1st ed. E-book: Springer; 2018; p.13-41.
  5. Referans5 Nasseh I, Al-Rawi W. Cone Beam Computed Tomography. Dental clinics of North America 2018; 62(3), 361–391.
  6. Referans6 Geleijns J. Computed tomography. In: Dance DR, Christofides S, Maidment ADA, McLean LD, Ng K-H, editors. Diagnostic Radiology Physics: A Handbook for Teachers and Students. Vienna: IAEA; 2014; p.257-290.
  7. Referans7 Samei E, Peck DJ, editors. Hendee's Physics of Medical Imaging. 5th ed. New Jersey: Wiley-Blackwell; 2019.
  8. Referans8 Wolbarst AB, Capasso P, Wyant AR, editors. Medical Imaging: Essentials for Physicians. 1st ed. New Jersey: Willey-Blackwell; 2013.

Details

Primary Language

English

Subjects

Dentistry

Journal Section

Research Article

Early Pub Date

April 29, 2023

Publication Date

April 30, 2023

Submission Date

October 31, 2022

Acceptance Date

March 17, 2023

Published in Issue

Year 2023 Volume: 7 Number: 1

APA
Polat, E., İncebeyaz, B., Deniz, H. A., & Eren, H. (2023). Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View. European Journal of Research in Dentistry, 7(1), 8-15. https://doi.org/10.29228/erd.37
AMA
1.Polat E, İncebeyaz B, Deniz HA, Eren H. Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View. Eur. J. res. Dent. (ERD). 2023;7(1):8-15. doi:10.29228/erd.37
Chicago
Polat, Elif, Burak İncebeyaz, Hatice Ahsen Deniz, and Hakan Eren. 2023. “Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View”. European Journal of Research in Dentistry 7 (1): 8-15. https://doi.org/10.29228/erd.37.
EndNote
Polat E, İncebeyaz B, Deniz HA, Eren H (April 1, 2023) Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View. European Journal of Research in Dentistry 7 1 8–15.
IEEE
[1]E. Polat, B. İncebeyaz, H. A. Deniz, and H. Eren, “Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View”, Eur. J. res. Dent. (ERD), vol. 7, no. 1, pp. 8–15, Apr. 2023, doi: 10.29228/erd.37.
ISNAD
Polat, Elif - İncebeyaz, Burak - Deniz, Hatice Ahsen - Eren, Hakan. “Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View”. European Journal of Research in Dentistry 7/1 (April 1, 2023): 8-15. https://doi.org/10.29228/erd.37.
JAMA
1.Polat E, İncebeyaz B, Deniz HA, Eren H. Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View. Eur. J. res. Dent. (ERD). 2023;7:8–15.
MLA
Polat, Elif, et al. “Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View”. European Journal of Research in Dentistry, vol. 7, no. 1, Apr. 2023, pp. 8-15, doi:10.29228/erd.37.
Vancouver
1.Elif Polat, Burak İncebeyaz, Hatice Ahsen Deniz, Hakan Eren. Evaluation of The Frequency of Artifacts in CBCT Depending on The Different Size of Field of View. Eur. J. res. Dent. (ERD). 2023 Apr. 1;7(1):8-15. doi:10.29228/erd.37