EN
VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE
Abstract
In this study, modification of carbon paste electrode (CPE) with a nano-structured substance, fumed silica (FS), was investigated to develop a voltammetric method for the determination of an endocrine disrupting chemical, estradiol (EST). FS prominently increased the voltammetric response of CPE towards EST. The parameters that affect the volmametric performance of modified CPE were examined to find the optimal conditions. Modified electrode showed a linear response towards EST between the concentration values of 0.1 mM and 15.0 mM EST. Limit of detection value for the method developed was calculated as 0.023 mM. Production reproducibility of the modified electrode was obtained as 3.6 %. The voltammetric behavior of EST was also examined in the presence of different possible substances to evaluate their interference effects. The modified electrode successfully discriminated the oxidation potential of EST in the presence of different substances. The determination of EST was tested in milk and pharmaceutical samples to evaluate the analytical performance of the method. The recovery analysis of EST in milk samples showed that the modified electrode can be used safely in these samples. The modified electrode also achieved the determination of EST in pharmaceutical samples.
Keywords
References
- [1] Ji L, Wang Y, Wu K, Zhang W. Simultaneous determination of environmental estrogens: Diethylstilbestrol and estradiol using Cu-BTC frameworks-sensitized electrode. Talanta 2016; 159: 215–21.
- [2] Moraes FC, Rossi B, Donatoni MC, de Oliveira KT, Pereira EC. Sensitive determination of 17β-estradiol in river water using a graphene based electrochemical sensor. Anal Chim Acta 2015; 881: 37–43.
- [3] Zhang X, Peng Y, Bai J, Ning B, Sun S, Hong X, et al. A novel electrochemical sensor based on electropolymerized molecularly imprinted polymer and gold nanomaterials amplification for estradiol detection. Sens Actuat B: Chem 2014; 200: 69–75.
- [4] Kang JH, Kondo F, Katayama Y. Human exposure to bisphenol A. Toxicology 2006; 226(2–3): 79–89.
- [5] Monerris MJ, Arivalo FJ, Fernandez H, Zon MA, Molina PG. Development of a very sensitive electrochemical immunosensor for the determination of 17-estradiol in bovine serum samples. Sens Actuat B: Chem 2015; 208: 525–31.
- [6] Huang KJ, Liu YJ, Zhang JZ, Cao JT, Liu YM. Aptamer/Au nanoparticles/cobalt sulfide nanosheets biosensor for 17β-estradiol detection using a guanine-rich complementary DNA sequence for signal amplification. Biosens Bioelectron 2015; 67: 184–91.
- [7] Yoon Y, Westerhoff P, Snyder SA, Esparza M. HPLC-fluorescence detection and adsorption of bisphenol A, 17β-estradiol, and 17α-ethynyl estradiol on powdered activated carbon. Water Res 2003; 37(14): 3530–7.
- [8] Jiang T, Zhao L, Chu B, Feng Q, Yan W, Lin JM. Molecularly imprinted solid-phase extraction for the selective determination of 17β-estradiol in fishery samples with high performance liquid chromatography. Talanta 2009; 78(2): 442–7.
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Publication Date
December 31, 2018
Submission Date
June 4, 2018
Acceptance Date
December 17, 2018
Published in Issue
Year 2018 Volume: 19 Number: 4
APA
Özcan, A., Topçuoğulları, D., & Özcan, A. A. (2018). VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, 19(4), 963-975. https://doi.org/10.18038/aubtda.430622
AMA
1.Özcan A, Topçuoğulları D, Özcan A A. VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE. Estuscience - Se. 2018;19(4):963-975. doi:10.18038/aubtda.430622
Chicago
Özcan, Ali, Duygu Topçuoğulları, and Ayça Atılır Özcan. 2018. “VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE”. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering 19 (4): 963-75. https://doi.org/10.18038/aubtda.430622.
EndNote
Özcan A, Topçuoğulları D, Özcan A A (December 1, 2018) VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering 19 4 963–975.
IEEE
[1]A. Özcan, D. Topçuoğulları, and A. A. Özcan, “VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE”, Estuscience - Se, vol. 19, no. 4, pp. 963–975, Dec. 2018, doi: 10.18038/aubtda.430622.
ISNAD
Özcan, Ali - Topçuoğulları, Duygu - Özcan, Ayça Atılır. “VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE”. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering 19/4 (December 1, 2018): 963-975. https://doi.org/10.18038/aubtda.430622.
JAMA
1.Özcan A, Topçuoğulları D, Özcan A A. VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE. Estuscience - Se. 2018;19:963–975.
MLA
Özcan, Ali, et al. “VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE”. Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering, vol. 19, no. 4, Dec. 2018, pp. 963-75, doi:10.18038/aubtda.430622.
Vancouver
1.Ali Özcan, Duygu Topçuoğulları, Ayça Atılır Özcan. VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE. Estuscience - Se. 2018 Dec. 1;19(4):963-75. doi:10.18038/aubtda.430622