Abstract

Vibration and noise are undesirable effects in daily life and energy-consuming systems. In this study, the effects of different refrigerants on noise and vibration in a sealed reciprocating compressor are discussed. The study compared the noise and vibration performances of refrigerants with lower ozone depletion potential (ODP) values compared to R22, which has a high ODP value. The study was carried out experimentally in two stages. Firstly, tests were conducted for the coefficient of performance (COP) of different refrigerants. Secondly, vibration and noise data were obtained experimentally for different refrigerants. The results obtained from the experiments showed that both the COP value and the compressor vibration and noise have different values for R22 refrigerant and other alternative refrigerants, but values close to R22 are obtained. It was observed that the compressor noise values and vibration values vary depending on the type of used refrigerant. Average vibration values were determined as 0.604 m/s2 in R22, 0.603 m/s2 in R438A, 0.593 m/s2 in R417A, 0.622 m/s2 in R422D and 0.637 m/s2 in R422A. When the noise values are examined, it was measured as 61.327 dB for R22, 62.913 dB for R438A, 62.187 dB for R417A, 63.715 dB for R422D and 64.913 dB for R422A. R417A, which has a 99% similar noise value to R22, was determined as an alternative refrigerant. COP values were found as 4.07 in R22, 3.98 in R438A, 3.63 in R417A, 3.37 in R422D, and 3.18 in R422A. R438A showing 95% similarity for COP can be used as an alternative to R22. Generally, it was observed that the noise and vibration values are very close to each other for all refrigerants examined.

Keywords

References

  1. 1. Ceylan, İ., G. Yıldız, A. E. Gürel, A. Ergün, and A. Tosun, The effect of malfunctions in air handling units on energy and exergy efficiency. Heat Transfer Research, 2020. 51(11): 1007-1028..
  2. 2. United Nations Development Programme UNDP. "20 years of success: Montreal protocol on substances that deplete the ozone layer.," [cited 2020 29 October]; Available from: http://www un.org. kh/undp/knowledge/publications/20-years-of-success-montreal-protocol-on-substances-that deplete-the-ozone-layer-2.
  3. 3. Li, W. L., and V. Eyo, Dynamic Analysis of a Compressor Mounting System. International Compressor Engineering Conference, 1996.
  4. 4. Hamilton, J. F., Measurement and control of compressor noise, West Lafayette, Purdue University, USA, 1988.
  5. 5. Celik, S., and E. C. Nsofor, Studies on the flow-induced noise at the evaporator of a refrigerating system. Applied Thermal Engineering, 2011. 31(14-15): p. 2485-2493.
  6. 6. Lee, C., Y. Cho, B. Baek, S. Lee, D. Hwang, and K. Jo, Analyses of refrigerator noises. In Proceedings of the IEEE International Symposium on Industrial Electronics, 2005: p. 1179-1184.
  7. 7. Han, H. S., W. B. Jeong, M. S. Kim, and T. H. Kim, Analysis of the root causes of refrigerant-induced noise in refrigerators. Journal of Mechanical Science and Technology, 2009. 23(12): p. 3245-3256.
  8. 8. Han, H. S., W. B. Jeong, M. S. Kim, S. Y. Lee, and M. Y. Seo, Reduction of the refrigerant-induced noise from the evaporator-inlet pipe in a refrigerator. International Journal of Refrigeration, 2010. 33(7): p. 1478-1488.

Details

Primary Language

English

Subjects

Mechanical Engineering

Journal Section

Research Article

Publication Date

August 15, 2021

Submission Date

January 12, 2021

Acceptance Date

March 20, 2021

Published in Issue

Year 2021 Volume: 5 Number: 2

APA
Cingiz, Z., Katırcıoğlu, F., Sarıdemir, S., Yıldız, G., & Çay, Y. (2021). Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise. International Advanced Researches and Engineering Journal, 5(2), 152-162. https://doi.org/10.35860/iarej.859423
AMA
1.Cingiz Z, Katırcıoğlu F, Sarıdemir S, Yıldız G, Çay Y. Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise. Int. Adv. Res. Eng. J. 2021;5(2):152-162. doi:10.35860/iarej.859423
Chicago
Cingiz, Zafer, Ferzan Katırcıoğlu, Suat Sarıdemir, Gökhan Yıldız, and Yusuf Çay. 2021. “Experimental Investigation of the Effects of Different Refrigerants Used in the Refrigeration System on Compressor Vibrations and Noise”. International Advanced Researches and Engineering Journal 5 (2): 152-62. https://doi.org/10.35860/iarej.859423.
EndNote
Cingiz Z, Katırcıoğlu F, Sarıdemir S, Yıldız G, Çay Y (August 1, 2021) Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise. International Advanced Researches and Engineering Journal 5 2 152–162.
IEEE
[1]Z. Cingiz, F. Katırcıoğlu, S. Sarıdemir, G. Yıldız, and Y. Çay, “Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise”, Int. Adv. Res. Eng. J., vol. 5, no. 2, pp. 152–162, Aug. 2021, doi: 10.35860/iarej.859423.
ISNAD
Cingiz, Zafer - Katırcıoğlu, Ferzan - Sarıdemir, Suat - Yıldız, Gökhan - Çay, Yusuf. “Experimental Investigation of the Effects of Different Refrigerants Used in the Refrigeration System on Compressor Vibrations and Noise”. International Advanced Researches and Engineering Journal 5/2 (August 1, 2021): 152-162. https://doi.org/10.35860/iarej.859423.
JAMA
1.Cingiz Z, Katırcıoğlu F, Sarıdemir S, Yıldız G, Çay Y. Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise. Int. Adv. Res. Eng. J. 2021;5:152–162.
MLA
Cingiz, Zafer, et al. “Experimental Investigation of the Effects of Different Refrigerants Used in the Refrigeration System on Compressor Vibrations and Noise”. International Advanced Researches and Engineering Journal, vol. 5, no. 2, Aug. 2021, pp. 152-6, doi:10.35860/iarej.859423.
Vancouver
1.Zafer Cingiz, Ferzan Katırcıoğlu, Suat Sarıdemir, Gökhan Yıldız, Yusuf Çay. Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise. Int. Adv. Res. Eng. J. 2021 Aug. 1;5(2):152-6. doi:10.35860/iarej.859423

Cited By



Creative Commons License

Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.