In this research, condition of resonance
effect which is a common problem for mechanical constructions has been studied in
perspective of unbalance failure of a bearing. A test setup designed respect to
case practices; constructed and located in laboratory conditions. A bearing in
the electrical motor, that is one of the elements in the test setup, has been selected
for gathering data in vibration and electrical consumption during the test. The
purpose of the research is testing condition of unbalance failure and resonance
for studying comparison in various predictive maintenance approaches. Test has
been implemented under the electricity frequency of 40.5 Hz that induced the
electrical motor for determining rotational speed. According to the analysis
results, inspecting of unbalance failure and resonance problem has been
detected more clearly by vibration analysis.
Subjects | Engineering |
---|---|
Journal Section | Research Article |
Authors | |
Publication Date | December 1, 2016 |
Published in Issue | Year 2016 |