Abstract

In heritage preservation, there is crucial need to identify the potential seismic risk in existing historic buildings for hazard mitigation, disaster preparedness and prior knowledge of potential hazards. Seismic risk evaluation is based on safety assessment which requires qualitative and quantitative data. This data is necessary before making any intervention decision. The qualitative data is visual inspection of decays, structural damages and deteriorations; and the quantitative data requires laboratory tests, structural analysis etc. Obtaining the quantitative data is detailed method, which necessitates specialists and takes more time and money. The fact that there are so many historic buildings and a few specialists on this field it is very important to make condition survey based on visual inspection as a first step of safety assessment procedure. According to these results necessity of detailed inspection and intervention and restoration works and the budged can be prioritized. This paper aims to present condition survey criteria generally and to focus on visual inspection as a first step of safety assessment. The data given in this paper is a part of author’s PhD study in which visual inspection method for assessing the risk level of masonry monumental historic structures is developed. The paper deals with Murat Pasha Mosque as a case study

Keywords

References

  1. Binda L. and Saisi A., Research On Historic Structures in Seismic Areas in Italy, Prog. Struct. Engng Mater. Wiley Interscience 7: 71 – 85, 2005.
  2. Roca, P., Recommendations for the Analysis, Conservation and Structural Restoration of Architectural Heritage, International Symposium on Studies on Historical Heritage, Antalya, Turkey, September 17 – 21, 2007.
  3. Gültekin, N., The Restoration Project of Murat Pasha Mosque (Murat Pasha Camisi Restorasyon Proejsi), Yildiz Technical University, Institute of Science, Istanbul, 2009 (Master thesis).
  4. Turkish Specification for Buildings to be Built in Seismic Zones – TSBBSZT, Ministry of Public Works and Settlement Government of Republic of Turkey, 2007.
  5. Kuban, D., Ottoman Architecture (Osmanlı Mimarisi), Yapı Endüstri Merkezi Publications, Istanbul, 2007.
  6. Vatan, M., Pre-assessment Method for Determining the Risk Level of Monumental Masonry Buildings (Anıtsal Yığma Binalarda Risk Düzeyinin Tespitine İlişkin Bir Öndeğerlendirme Yöntemi), Yildiz Technical University, Institute of Science and Technology, Architectural Department, Istanbul, 2010 (PhD thesis).
  7. Lourenco, P.B. and Roque J.A., Simplified Indexes for the Seismic Vulnerability of Ancient Masonry Buildings, Construction and Building Materials, 20:200-208, 2006.
  8. Aköz, F. and Yüzer, N., The Methods for Determination of Material Properties of Historical Buildings (Tarihi Yapılarda Malzeme Özelliklerinin Belirlenmesinde Uygulanan Yöntemler), Proceedings of 1st Symposium on Education of Civil Engineering, Turkish Chamber of Civil Engineers, 6-7 November 2009, Antalya, Turkey.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Meltem Vatan This is me

Publication Date

June 1, 2012

Submission Date

June 1, 2012

Acceptance Date

-

Published in Issue

Year 2012 Volume: 2 Number: 1

APA
Vatan, M. (2012). CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE. International Journal of Electronics Mechanical and Mechatronics Engineering, 2(1), 147-156. https://izlik.org/JA75UD98ZX
AMA
1.Vatan M. CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE. IJEMME. 2012;2(1):147-156. https://izlik.org/JA75UD98ZX
Chicago
Vatan, Meltem. 2012. “CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE”. International Journal of Electronics Mechanical and Mechatronics Engineering 2 (1): 147-56. https://izlik.org/JA75UD98ZX.
EndNote
Vatan M (June 1, 2012) CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE. International Journal of Electronics Mechanical and Mechatronics Engineering 2 1 147–156.
IEEE
[1]M. Vatan, “CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE”, IJEMME, vol. 2, no. 1, pp. 147–156, June 2012, [Online]. Available: https://izlik.org/JA75UD98ZX
ISNAD
Vatan, Meltem. “CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE”. International Journal of Electronics Mechanical and Mechatronics Engineering 2/1 (June 1, 2012): 147-156. https://izlik.org/JA75UD98ZX.
JAMA
1.Vatan M. CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE. IJEMME. 2012;2:147–156.
MLA
Vatan, Meltem. “CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE”. International Journal of Electronics Mechanical and Mechatronics Engineering, vol. 2, no. 1, June 2012, pp. 147-56, https://izlik.org/JA75UD98ZX.
Vancouver
1.Meltem Vatan. CONDITION SURVEY OF HISTORIC BUILDINGS BY VISUAL INSPECTION - CASE STUDY: MURAT PASHA MOSQUE. IJEMME [Internet]. 2012 Jun. 1;2(1):147-56. Available from: https://izlik.org/JA75UD98ZX