Abstract

A great deal of research is being carried out to ameliorate the performance of grid-connected photovoltaic (PV) systems. This paper shoes the performance of a 1kW PV grid-connected system under grid failure. Among grid faults, the cases of islanding and grid voltage sags are tested with the proposed system. Hysteresis current control combined with active Islanding Detection Methods (IDMs) is developed to determine the effectiveness of the single phase full bridge inverter to detect islanding. Single Phase Induction Motor (SPIM) is taken as local load to shoes the effects of grid voltage sags with different depths and durations. A Theoretical, simulations, and experimental result shoes the performance of the proposed system.

Keywords

References

  1. European Photovoltaic Industry Association (EPIA), Market Report 2011.
  2. IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE Std 1547.2-2008.
  3. M. G. Villalva, J. R. Gazoli, E. Ruppert, “ Modelling and circuit-based
  4. Brazilian Journal of Power Electronics, 2009, vol. 14, no. 1, ISSN 1414-8862, pp. 35-45.
  5. M. Trabelsi, M. Brahim, K.A Ghazi, L. Ben-Brahim, S. Al-Dosari, J. Belhadj “A new design of predictive controller combined with an islanding detection method for a grid connected Photovoltaic Power Conditioning System” International Renewable Energy Congress, Tunisia, December 2011, pp.352-358.
  6. M. Xu, R.V.N. Melnik, U. Borup, “Modeling anti- islanding protection devices for photovoltaic systems”, Elsevier on Renewable Energy 29 (2004), pp. 2195-2216. [6] L.A.C. Lopes, H. Sun, “Performance assessment of active frequency drifting islanding detection methods”, IEEE Transaction on Energy Conversion,Vol.21, No.1, March 2006, pp. 171-180.
  7. Z. Ye, A. Kowalkar, Y. Zhang, P. Du, and R.Walling, “Evaluation of anti-islanding schemes based on non- detection zone concept,” IEEE Trans. Power Electron. (2004), vol. 19, no. 5, pp. 1171-1176.
  8. M.E. Ropp, M. Begovic, A. Rohatgi, “Determining the Relative Effectiveness of Islanding Detection Methods Using Phase Criteria and Non-detection Zones”, IEEE Transactions on Energy Conversion, Vol. 15, No. 3, September 2000, pp. 290-296.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Mouhanned Brahım This is me

Jamel Belhadj This is me

Publication Date

December 1, 2013

Submission Date

February 3, 2016

Acceptance Date

-

Published in Issue

Year 2013 Volume: 3 Number: 4

APA
Brahım, M., & Belhadj, J. (2013). Performance of PV grid-connected system under grid failure. International Journal Of Renewable Energy Research, 3(4), 754-762. https://izlik.org/JA97ZU48ST
AMA
1.Brahım M, Belhadj J. Performance of PV grid-connected system under grid failure. International Journal Of Renewable Energy Research. 2013;3(4):754-762. https://izlik.org/JA97ZU48ST
Chicago
Brahım, Mouhanned, and Jamel Belhadj. 2013. “Performance of PV Grid-Connected System under Grid Failure”. International Journal Of Renewable Energy Research 3 (4): 754-62. https://izlik.org/JA97ZU48ST.
EndNote
Brahım M, Belhadj J (December 1, 2013) Performance of PV grid-connected system under grid failure. International Journal Of Renewable Energy Research 3 4 754–762.
IEEE
[1]M. Brahım and J. Belhadj, “Performance of PV grid-connected system under grid failure”, International Journal Of Renewable Energy Research, vol. 3, no. 4, pp. 754–762, Dec. 2013, [Online]. Available: https://izlik.org/JA97ZU48ST
ISNAD
Brahım, Mouhanned - Belhadj, Jamel. “Performance of PV Grid-Connected System under Grid Failure”. International Journal Of Renewable Energy Research 3/4 (December 1, 2013): 754-762. https://izlik.org/JA97ZU48ST.
JAMA
1.Brahım M, Belhadj J. Performance of PV grid-connected system under grid failure. International Journal Of Renewable Energy Research. 2013;3:754–762.
MLA
Brahım, Mouhanned, and Jamel Belhadj. “Performance of PV Grid-Connected System under Grid Failure”. International Journal Of Renewable Energy Research, vol. 3, no. 4, Dec. 2013, pp. 754-62, https://izlik.org/JA97ZU48ST.
Vancouver
1.Mouhanned Brahım, Jamel Belhadj. Performance of PV grid-connected system under grid failure. International Journal Of Renewable Energy Research [Internet]. 2013 Dec. 1;3(4):754-62. Available from: https://izlik.org/JA97ZU48ST