The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization

Volume: 3 Number: 1 March 1, 2013
  • Ali Kecebas
EN

The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization

Abstract

This study deals with exergetic and exergoeconomic analysis of geothermal district heating system (GDHS) which offers nowadays many disadvantages in the aspect of high heat losses and costs. The Afyon GDHS located in the city of Afyonkarahisar/Turkey is selected as a case study. The modified productive structure analysis (MOPSA) is used for exergy-cost evaluation. In these analyses, mass and energy conservation laws are applied to each component of the system. Quantitative balances of the exergy and exergetic cost for the whole system and its each component is carefully considered. The results show that about 52.49% of the input cost of the Afyon GDHS is lost from the heat exchangers, 16.26% from pipes, and 7.22% from pumps. The heat exchangers and their efficiencies should be improved as high as possible to decrease the system costs. The unit cost of heating from geothermal water in the Afyon GDHS is about 711.491 US$/h at 100% load conditions.

Keywords

References

  1. S. Erdogmus, H. Aras, E. Koc, “Evaluation of alternative fuels for residential heating in Turkey using analytic network process (ANP) with group decision making”, Renewable and Sustainable Energy Review, vol. 10, pp. 269-279, 2006.
  2. O. Buyukalaca, H. Bulut, “Detailed weather data for the provinces covered by the Southeastern Anatolia Project (GAP) of Turkey”, Applied Energy, vol. 77, 187-204, 2004.
  3. O. Kaynakli, “A study on residential heating energy requirement and optimum insulation thickness”, Renewable Energy, vol. 33, pp. 1164-1172, 2008.
  4. K. J. Ptasinskia, M. N. Koymansb, H. H. G. Verspagen, “Performance of the Dutch Energy Sector based on energy, exergy and extended exergy accounting”, Energy, vol. 31, pp. 3135-3144, 2006.
  5. A. Bejan, G. Tsatsaronis, M. J. Moran, “Thermal design and optimization”, Wiley, New York, USA, 1996.
  6. G. Tsatsaronis, M. Winhold, “Exergoeconomic analysis and evaluation of energy conversion plants. 1. A new general methodology”, Energy, vol. 10, pp. 69-80, 1985.
  7. A. Lazzarettoa, G. Tsatsaronis, “SPECO: A systematic and general methodology for calculating efficiencies and costs in thermal systems”, Energy, vol. 31 pp. 1257-1289, 2006.
  8. S. Oh, H. Pang, S. Kim, H. Kwak, “Exergy analysis for a gas-turbine cogeneration system”, Journal of Engineering for Gas Turbines and Power, vol. 118, pp. 782-791, 1996.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Ali Kecebas This is me

Publication Date

March 1, 2013

Submission Date

February 3, 2016

Acceptance Date

-

Published in Issue

Year 2013 Volume: 3 Number: 1

APA
Kecebas, A. (2013). The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization. International Journal Of Renewable Energy Research, 3(1), 60-67. https://izlik.org/JA94RC29SE
AMA
1.Kecebas A. The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization. International Journal Of Renewable Energy Research. 2013;3(1):60-67. https://izlik.org/JA94RC29SE
Chicago
Kecebas, Ali. 2013. “The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization”. International Journal Of Renewable Energy Research 3 (1): 60-67. https://izlik.org/JA94RC29SE.
EndNote
Kecebas A (March 1, 2013) The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization. International Journal Of Renewable Energy Research 3 1 60–67.
IEEE
[1]A. Kecebas, “The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization”, International Journal Of Renewable Energy Research, vol. 3, no. 1, pp. 60–67, Mar. 2013, [Online]. Available: https://izlik.org/JA94RC29SE
ISNAD
Kecebas, Ali. “The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization”. International Journal Of Renewable Energy Research 3/1 (March 1, 2013): 60-67. https://izlik.org/JA94RC29SE.
JAMA
1.Kecebas A. The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization. International Journal Of Renewable Energy Research. 2013;3:60–67.
MLA
Kecebas, Ali. “The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization”. International Journal Of Renewable Energy Research, vol. 3, no. 1, Mar. 2013, pp. 60-67, https://izlik.org/JA94RC29SE.
Vancouver
1.Ali Kecebas. The Modified Productive Structure Analysis of Afyon Geothermal District Heating System for Economic Optimization. International Journal Of Renewable Energy Research [Internet]. 2013 Mar. 1;3(1):60-7. Available from: https://izlik.org/JA94RC29SE