A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion

Volume: 2 Number: 1 March 1, 2012
  • Tarak Salmi
  • Mounir Bouzguenda
  • Adel Gastli
  • Ahmed Masmoudi
EN

A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion

Abstract

The elimination of the transformer in solar photovoltaic inverters has reduced the size, the weight and the losses in the system.  On the other hand, the galvanic connection between the DC source and the grid generates leakage current through the earth parasitic capacitance. The leakage current depends on both the inverter topology and the control strategy. Among the existing inverters is the Highly Efficient and Reliable Inverter Concept (HERIC) topology that has low leakage current level and high efficiency. However, this topology suffers from low frequency harmonics and current zero crossings distortions. To eliminate these harmonics and distortions, a new transformerless inverter is proposed.   The design is a conventional full bridge inverter with an extra AC bypass.  The bypass branch disconnects the inverter from the grid during the freewheeling period.  Simulation results indicate that the zero crossings distortions are totally eliminated and that the low frequency harmonics are significantly reduced as a result of the appropriate applied control.  Moreover, losses analysis of the proposed design yields an efficiency of up to 94.14% and shows that the topology meets relevant standards.

Keywords

References

  1. Fritz Schimpf, Lars E. Norum, “Grid Connected Converters for Photovoltaic, State of the Art, Ideas for Improvement NORPIE/2008, Nordic Workshop on Power and Industrial Electronics, June 9-11, 2008, pp.1-5.
  2. T. Kerekes, R. Teodorescu, M. Liserre, “Common Mode Voltage in case of Transformerless PV Inverters Connected to the Grid”, IEEE International Symposium on Industrial Electronics, June 30th- July 2nd 2008, pp. 2395.
  3. W.T. Franke, N. Oestreich, F.W. Fuchs, "Comparison of Transformerless Converter Topologies for Photovoltaic Application Concerning Efficiency and Mechanical Volume", IEEE International Symposium on Industrial Electronics, 2010, pp.724-729.
  4. Oscar Lopez, Remus Teodorescu, Francisco Freijedo, Jesus Doval-Gandoy, "Eliminating Ground Current in a Transformerless Transactions on Energy Conversion, Vol. 25, No 1, Mar. , pp. 140-147. Application", IEEE W. Bower and J. Wiles, “Investigation of Ground-Fault Protection Devices for Photovoltaic Power System Applications”, Proceedings of the 28th IEEE Conference on Photovoltaic Specialists, 2000, pp. 1378-1383.
  5. Roberto González, Eugenio Gubía, Jesşs López, and Luis Marroyo, “Transformerless Single-Phase Multilevel- Based Photovoltaic Inverter”, IEEE Transactions on Industrial Electronics, Vol. 55, No. 7, July 2008, pp.2694-2702.
  6. Lin Ma, Fen Tang, Fei Zhou, Xinmin Jin and Yibin Tong, "Leakage Transformer-less PV inverter connected to the grid", Proceedings of the IEEE International Conference on Sustainable Energy Technologies, 24-27 Nov. 2008, pp.285-289. of a Single-Phase
  7. Roberto Gonzalez, Jesus Lopez, Pablo Sanchis, Eugenio Gubia, Alfredo Ursua and Luis Marroy, “High-Efficiency Transformerless Single-phase Photovoltaic Inverter”, Proceedings of the 12th IEEE Conference on Power Electronics and Motion Control, 30 Sep. 2006, pp.1895
  8. Valentini, M. Raducu, A. Sera, D. Teodorescu, R., “PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation”, Proceedings of11th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM 2008, Printed on CD.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Tarak Salmi This is me

Mounir Bouzguenda This is me

Adel Gastli This is me

Ahmed Masmoudi This is me

Publication Date

March 1, 2012

Submission Date

February 3, 2016

Acceptance Date

-

Published in Issue

Year 2012 Volume: 2 Number: 1

APA
Salmi, T., Bouzguenda, M., Gastli, A., & Masmoudi, A. (2012). A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion. International Journal Of Renewable Energy Research, 2(1), 140-146. https://izlik.org/JA96UX47WZ
AMA
1.Salmi T, Bouzguenda M, Gastli A, Masmoudi A. A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion. International Journal Of Renewable Energy Research. 2012;2(1):140-146. https://izlik.org/JA96UX47WZ
Chicago
Salmi, Tarak, Mounir Bouzguenda, Adel Gastli, and Ahmed Masmoudi. 2012. “A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion”. International Journal Of Renewable Energy Research 2 (1): 140-46. https://izlik.org/JA96UX47WZ.
EndNote
Salmi T, Bouzguenda M, Gastli A, Masmoudi A (March 1, 2012) A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion. International Journal Of Renewable Energy Research 2 1 140–146.
IEEE
[1]T. Salmi, M. Bouzguenda, A. Gastli, and A. Masmoudi, “A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion”, International Journal Of Renewable Energy Research, vol. 2, no. 1, pp. 140–146, Mar. 2012, [Online]. Available: https://izlik.org/JA96UX47WZ
ISNAD
Salmi, Tarak - Bouzguenda, Mounir - Gastli, Adel - Masmoudi, Ahmed. “A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion”. International Journal Of Renewable Energy Research 2/1 (March 1, 2012): 140-146. https://izlik.org/JA96UX47WZ.
JAMA
1.Salmi T, Bouzguenda M, Gastli A, Masmoudi A. A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion. International Journal Of Renewable Energy Research. 2012;2:140–146.
MLA
Salmi, Tarak, et al. “A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion”. International Journal Of Renewable Energy Research, vol. 2, no. 1, Mar. 2012, pp. 140-6, https://izlik.org/JA96UX47WZ.
Vancouver
1.Tarak Salmi, Mounir Bouzguenda, Adel Gastli, Ahmed Masmoudi. A Novel Transformerless Inverter Topology Without Zero-Crossing Distortion. International Journal Of Renewable Energy Research [Internet]. 2012 Mar. 1;2(1):140-6. Available from: https://izlik.org/JA96UX47WZ