Islanding Detection Method for a Hybrid Renewable Energy System

Volume: 1 Number: 1 March 1, 2011
  • Mamadou Lamine Doumbia
  • Mylène Robitaille
  • Kodjo Agbossou
  • Rémy Simard
EN

Islanding Detection Method for a Hybrid Renewable Energy System

Abstract

The Hydrogen Research Institute (HRI) developed a hybrid renewable energy power system that uses a wind turbine, a photovoltaic array and a fuel cell. In order to fulfill utility requirements , an islanding protection device is being developed. This paper presents the passive (Under/Over Voltage, Under/Over Frequency) and active (Sandia Frequency Shift and Sandia Voltage Shift) protection methods that were chosen to be added to the system. Those four methods were combined in an innovative way in order to benefit from the strengths of each of them. This way, the islanding protection will be more efficient and the non detection zone will be reduced. This paper also presents a Matlab/Simulink model of the protection device and the simulation results that were obtained using different critical operating conditions for which the clearing times can surpass those defined by the Canadian standard C22.2 No 107.1-01. This standard is similar to the IEEE 1547 standard with a few differences. Finally, the paper presents the experimental results for a grid-connected inverter, designed by the HRI, which uses the islanding protection method presented above.

Keywords

References

  1. T. Ackermann, G. Andersson, L. Söder, “Electricity Market regulations and their Impact on Distributes Generation”, Proceedings of International Conference on Electric Utility Deregulation and Restructuring and Power Technologies 2000, London, 4-7 April 2000, pp. 608-613.
  2. S. Odagiri, “Connection between Dispersed Power Sources and Utility Distribution Systems: TEPCO’s Technical Challenges”, Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. IEEE/PES, 6-10 October 2002, Vol. 2, pp. 1364-1366.
  3. IEEE, IEEE Standard for Interconnecting Distributed Sources with Electric Power Systems, IEEE Standard 1547, 2003.
  4. M.E. Ropp, K. Aaker, J. Haigh, N. Sabbah, “Using Power Line Carrier Communications to Prevent Islanding”, Proceedings of the 28th IEEE Photovoltaic Specialists Conference, Sept 17-22 2000, pp.1675-1678.
  5. Canadian Standards Association, General Use Power Supplies, CSA Standard C22.2 No. 107.1-01, 2001.
  6. W. Bower, M. Ropp, Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems, Sandia Report SAND 2002- 3591, 2002.
  7. S.-J. Huang, F.-S. Pai, “A New Approach to Islanding Detection of Dispersed Generators with Self- commuted Power Converters”, IEEE Transactions on Power Delivery, vol. 15, pp. 500-507, April 2000.
  8. Z. Ye, A. Kolwalkar, Y. Zhang, P. Du, R. Walling, “Evaluation of Anti-Islanding Schemes Based on Nondetection Zone Concept”, IEEE Transactions on Power Electronics, vol. 19, no. 5, September 2004, pp. 1171-1176.

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Mamadou Lamine Doumbia This is me

Mylène Robitaille This is me

Kodjo Agbossou This is me

Rémy Simard This is me

Publication Date

March 1, 2011

Submission Date

February 3, 2016

Acceptance Date

-

Published in Issue

Year 2011 Volume: 1 Number: 1

APA
Doumbia, M. L., Robitaille, M., Agbossou, K., & Simard, R. (2011). Islanding Detection Method for a Hybrid Renewable Energy System. International Journal Of Renewable Energy Research, 1(1), 41-53. https://izlik.org/JA27JD57DX
AMA
1.Doumbia ML, Robitaille M, Agbossou K, Simard R. Islanding Detection Method for a Hybrid Renewable Energy System. International Journal Of Renewable Energy Research. 2011;1(1):41-53. https://izlik.org/JA27JD57DX
Chicago
Doumbia, Mamadou Lamine, Mylène Robitaille, Kodjo Agbossou, and Rémy Simard. 2011. “Islanding Detection Method for a Hybrid Renewable Energy System”. International Journal Of Renewable Energy Research 1 (1): 41-53. https://izlik.org/JA27JD57DX.
EndNote
Doumbia ML, Robitaille M, Agbossou K, Simard R (March 1, 2011) Islanding Detection Method for a Hybrid Renewable Energy System. International Journal Of Renewable Energy Research 1 1 41–53.
IEEE
[1]M. L. Doumbia, M. Robitaille, K. Agbossou, and R. Simard, “Islanding Detection Method for a Hybrid Renewable Energy System”, International Journal Of Renewable Energy Research, vol. 1, no. 1, pp. 41–53, Mar. 2011, [Online]. Available: https://izlik.org/JA27JD57DX
ISNAD
Doumbia, Mamadou Lamine - Robitaille, Mylène - Agbossou, Kodjo - Simard, Rémy. “Islanding Detection Method for a Hybrid Renewable Energy System”. International Journal Of Renewable Energy Research 1/1 (March 1, 2011): 41-53. https://izlik.org/JA27JD57DX.
JAMA
1.Doumbia ML, Robitaille M, Agbossou K, Simard R. Islanding Detection Method for a Hybrid Renewable Energy System. International Journal Of Renewable Energy Research. 2011;1:41–53.
MLA
Doumbia, Mamadou Lamine, et al. “Islanding Detection Method for a Hybrid Renewable Energy System”. International Journal Of Renewable Energy Research, vol. 1, no. 1, Mar. 2011, pp. 41-53, https://izlik.org/JA27JD57DX.
Vancouver
1.Mamadou Lamine Doumbia, Mylène Robitaille, Kodjo Agbossou, Rémy Simard. Islanding Detection Method for a Hybrid Renewable Energy System. International Journal Of Renewable Energy Research [Internet]. 2011 Mar. 1;1(1):41-53. Available from: https://izlik.org/JA27JD57DX