Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions

Volume: 32 Number: 2 June 1, 2012
  • Dilek Nur Özen
  • Kemal Altınışık
EN TR

Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions

Abstract

In this study, analysis of thermal performance of finned tube evaporator under dry conditions has numerically been done. The heat convection coefficient in air and refrigerant sides were calculated by considering their varying properties. In addition, the surface temperature of fin and tubes along the fin were calculated. A numerical model was developed in order to calculate the overall thermal permeability (UA) in transient regime. The numerical model was solved by using Matlab R2010 program. The overall thermal permeability (UA) was examined under different air inlet temperatures and air velocity. In addition, variation of the convection heat transfer coefficient with respect to quality at the refrigerant side was examined

Keywords

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Dilek Nur Özen This is me

Kemal Altınışık This is me

Publication Date

June 1, 2012

Submission Date

June 1, 2012

Acceptance Date

-

Published in Issue

Year 2012 Volume: 32 Number: 2

APA
Özen, D. N., & Altınışık, K. (2012). Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi Ve Tekniği Dergisi, 32(2), 145-150. https://izlik.org/JA84HT62NX
AMA
1.Özen DN, Altınışık K. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi. 2012;32(2):145-150. https://izlik.org/JA84HT62NX
Chicago
Özen, Dilek Nur, and Kemal Altınışık. 2012. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi Ve Tekniği Dergisi 32 (2): 145-50. https://izlik.org/JA84HT62NX.
EndNote
Özen DN, Altınışık K (June 1, 2012) Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi 32 2 145–150.
IEEE
[1]D. N. Özen and K. Altınışık, “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”, Isı Bilimi ve Tekniği Dergisi, vol. 32, no. 2, pp. 145–150, June 2012, [Online]. Available: https://izlik.org/JA84HT62NX
ISNAD
Özen, Dilek Nur - Altınışık, Kemal. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi ve Tekniği Dergisi 32/2 (June 1, 2012): 145-150. https://izlik.org/JA84HT62NX.
JAMA
1.Özen DN, Altınışık K. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi. 2012;32:145–150.
MLA
Özen, Dilek Nur, and Kemal Altınışık. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi Ve Tekniği Dergisi, vol. 32, no. 2, June 2012, pp. 145-50, https://izlik.org/JA84HT62NX.
Vancouver
1.Dilek Nur Özen, Kemal Altınışık. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi [Internet]. 2012 Jun. 1;32(2):145-50. Available from: https://izlik.org/JA84HT62NX