EN
TR
Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions
Abstract
In this study, analysis of thermal performance of finned tube evaporator under dry conditions has numerically been done. The heat convection coefficient in air and refrigerant sides were calculated by considering their varying properties. In addition, the surface temperature of fin and tubes along the fin were calculated. A numerical model was developed in order to calculate the overall thermal permeability (UA) in transient regime. The numerical model was solved by using Matlab R2010 program. The overall thermal permeability (UA) was examined under different air inlet temperatures and air velocity. In addition, variation of the convection heat transfer coefficient with respect to quality at the refrigerant side was examined
Keywords
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Publication Date
June 1, 2012
Submission Date
June 1, 2012
Acceptance Date
-
Published in Issue
Year 2012 Volume: 32 Number: 2
APA
Özen, D. N., & Altınışık, K. (2012). Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi Ve Tekniği Dergisi, 32(2), 145-150. https://izlik.org/JA84HT62NX
AMA
1.Özen DN, Altınışık K. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi. 2012;32(2):145-150. https://izlik.org/JA84HT62NX
Chicago
Özen, Dilek Nur, and Kemal Altınışık. 2012. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi Ve Tekniği Dergisi 32 (2): 145-50. https://izlik.org/JA84HT62NX.
EndNote
Özen DN, Altınışık K (June 1, 2012) Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi 32 2 145–150.
IEEE
[1]D. N. Özen and K. Altınışık, “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”, Isı Bilimi ve Tekniği Dergisi, vol. 32, no. 2, pp. 145–150, June 2012, [Online]. Available: https://izlik.org/JA84HT62NX
ISNAD
Özen, Dilek Nur - Altınışık, Kemal. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi ve Tekniği Dergisi 32/2 (June 1, 2012): 145-150. https://izlik.org/JA84HT62NX.
JAMA
1.Özen DN, Altınışık K. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi. 2012;32:145–150.
MLA
Özen, Dilek Nur, and Kemal Altınışık. “Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi”. Isı Bilimi Ve Tekniği Dergisi, vol. 32, no. 2, June 2012, pp. 145-50, https://izlik.org/JA84HT62NX.
Vancouver
1.Dilek Nur Özen, Kemal Altınışık. Kanatlı Borulu Evaporatörün Kuru Şartlar Altında Isıl Performansının İncelenmesi. Isı Bilimi ve Tekniği Dergisi [Internet]. 2012 Jun. 1;32(2):145-50. Available from: https://izlik.org/JA84HT62NX