EN
TR
Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions
Abstract
In this study, analysis of thermal performance of finned tube evaporator under dry conditions has numerically been done. The heat convection coefficient in air and refrigerant sides were calculated by considering their varying properties. In addition, the surface temperature of fin and tubes along the fin were calculated. A numerical model was developed in order to calculate the overall thermal permeability (UA) in transient regime. The numerical model was solved by using Matlab R2010 program. The overall thermal permeability (UA) was examined under different air inlet temperatures and air velocity. In addition, variation of the convection heat transfer coefficient with respect to quality at the refrigerant side was examined
Keywords
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
June 1, 2012
Submission Date
June 1, 2012
Acceptance Date
-
Published in Issue
Year 2012 Volume: 32 Number: 2
APA
Özen, D. N., & Altınışık, K. (2012). Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions. Journal of Thermal Science and Technology, 32(2), 145-150. https://izlik.org/JA84HT62NX
AMA
1.Özen DN, Altınışık K. Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions. Journal of Thermal Science and Technology. 2012;32(2):145-150. https://izlik.org/JA84HT62NX
Chicago
Özen, Dilek Nur, and Kemal Altınışık. 2012. “Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions”. Journal of Thermal Science and Technology 32 (2): 145-50. https://izlik.org/JA84HT62NX.
EndNote
Özen DN, Altınışık K (June 1, 2012) Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions. Journal of Thermal Science and Technology 32 2 145–150.
IEEE
[1]D. N. Özen and K. Altınışık, “Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions”, Journal of Thermal Science and Technology, vol. 32, no. 2, pp. 145–150, June 2012, [Online]. Available: https://izlik.org/JA84HT62NX
ISNAD
Özen, Dilek Nur - Altınışık, Kemal. “Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions”. Journal of Thermal Science and Technology 32/2 (June 1, 2012): 145-150. https://izlik.org/JA84HT62NX.
JAMA
1.Özen DN, Altınışık K. Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions. Journal of Thermal Science and Technology. 2012;32:145–150.
MLA
Özen, Dilek Nur, and Kemal Altınışık. “Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions”. Journal of Thermal Science and Technology, vol. 32, no. 2, June 2012, pp. 145-50, https://izlik.org/JA84HT62NX.
Vancouver
1.Dilek Nur Özen, Kemal Altınışık. Investigation of Thermal Performance of Finned Tube Evaporator under Dry Conditions. Journal of Thermal Science and Technology [Internet]. 2012 Jun. 1;32(2):145-50. Available from: https://izlik.org/JA84HT62NX