SEMPTOMSUZ MİYOKARD İSKEMİSİ VE İNFARKTÜSÜNÜN ERKEN TANISINDA ÇOK KESİTLİ BİLGİSAYARLI TOMOGRAFİK KORONER ANJİYOGRAFİNİN YERİ VE ÖNEMİ: (UZUN DÖNEM TAKİP EDİLEN İKİ OLGU NEDENİYLE)
Abstract
Keywords
References
- Achenbach S, Moselewski F, Ropers D, Ferencik M, Hoffmann U, MacNeill B, Pohle K, Baum U, Anders K, Jang IK, Daniel WG, Brady TJ. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment- based comparison with intravscular ultrasound. Circulation 2004; 109:14-17.
- Dirksen MS, Bax JJ, de Ross A, Jukema JW, van der Geest RJ, Geleijns K, Boersma E, van der Wall EE, Lamb HJ. Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. Am J Cardiol 2002; 90:1157-1160.
- Erol Ç, Candemir B. Koroner arter hastalığı Erzengin F, Büyüköztürk K. Kalbin radyolojik muayenesi; bilgisayarlı tomografi ve manyetik rezonans görüntüleme yöntemi. İç Hastalıkları Kitabı Cilt 2 Edit. Prof. Dr.K.Büyüköztürk. Nobel Tıp Kitapevleri LTD.ŞTİ. 2007; 1663-1686
- Erzengin F. Editöre mektup. Koroner arter atereosklerozunda plak oluşumu ve kalsifik tutulum; klasik intimal kaskat yolu dışında; yani yalnız endotel altından değil, Adventisya Tabakası’ndan da başlar ve ilerler, MN Kardioloji, 2009; 16:219-221.
- Filippo Cademartiri, Erica Maffei, Nico R.Mollet. Is dual-source CT coronary angiography ready fort the real world? Department of Radiology and Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands; Department of Radiology and Cardiology, Azienda Ospedaliero-Universitaria/University Hospital, Parma, Italy. Eur Heart Journal 2008; 29:701-703.
- Hoffmann U, Ferencik M, Cury RC, Pena AJ. Coronary CT angiography. J Nucl Med., 2006; 47:797-806.
- Kopp AF, Schroeder S, Baumbach A, Kuettner A, Georg C, Ohnesorge B, Heuschmid M, Kuzo R, Claussen CD. Noninvasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 2001; 11:1607-1611.
- Leschha S, Alkadhi H, Plass A, Desbiolles L, Grunenfelder J, Merincek B, Wildermuth S.Accuracy of MSCT coronary angiograhy with 64-slice technology: First experience. Eur Heart J 2005; 1482-1487.
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Authors
Faruk Erzengin
This is me
Mustafa Özcan
This is me
Erhan Teker
This is me
Sami Özgül
This is me
İpek Yönal
This is me
Kamil Adalet
This is me
Publication Date
November 10, 2011
Submission Date
November 10, 2011
Acceptance Date
-
Published in Issue
Year 2011 Volume: 74 Number: 2