Research Article

EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY

Volume: 84 Number: 4 October 1, 2021
TR EN

EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY

Abstract

Objective: The presence of metallic impurities can pose a serious concern due to their interaction with receptor-specific biomolecules that require the highest possible specific activity, especially in radioactive labeling. There are studies in which Zn and other toxic metal pollution increases if the generator is not used for a long time. In this study the effect of pre-elution on chemical and radiochemical impurities in the synthesis product was investigated. Material and Methods: In the study, 68GaPSMA-11 labeling was performed with the generator eluate that was not used for one month (sample 1). A blank elution was taken 24 hours after using the generator (sample 2). In the next 24 hours, the second 68GaPSMA- 11 labeling was performed (sample 3). Six hours after this labeling, another 68GaPSMA-11 synthesis was performed (sample 4). Eluates were analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results: Results was reported as a table in μg/ml. 68Ge levels determined at 0.018 ppm, 0.012 ppm and 0.009 ppm levels in the labeled products were determined below the pharmacopoeia limits. Zn(II) impurities were found as 0.625 ppm in the labeling performed without generator pre-elution. In generator pre-eluted labelings; Zn(II) impurities were determined as 0.133 ppm and 0.108 ppm. Conclusion: Pre-elution of the generator prior to synthesis does not seem to be a chemical requirement other than zinc pollution. 68GaPSMA-11 can be pre-eluted for high labeling efficiency, but it is thought that pre-elution is not significant in terms of chemical and radiochemical contamination.

Keywords

References

  1. 1. Greene MW, Tucker W. An improved gallium-68 cow. Appl Radiat Isot 1961;12(1-2): 62-3. [CrossRef]
  2. 2. Roesch F. Maturation of a Key Resource–The Germanium-68/ Gallium-68 Generator: Development and New Insights. Curr Radiopharm 2012;5(3):202-11. [CrossRef]
  3. 3. Velikyan I, Antoni G, Sörensen J, Estrada S. Organ biodistribution of Germenium-68 in rest in the oresence and absence of [(68)Ga] Ga-DOTA-TOC for the extrapolation to the human organ and wholebody radration dosimetry. Am J Nucl Med Mol Imaging 2013;3(2):154-65.
  4. 4. Velikyan, I. 68Ga-Based radiopharmaceuticals: production and application relationship. Molecules 2015;20(7):12913- 43. [CrossRef]
  5. 5. Uğur, A. Yaylalı, O. Yüksel, D. Examination of metallic impurities of 68Ge/68Ga generators used for radioactive labeling of peptides in clinical PET applications. Nucl Med Commun 2021;42(1):81-5. [CrossRef]
  6. 6. Vyas CK, Lee JY, Hur MG, Yang SD, Kong YB, Lee EJ, et al. Chitosan-TiO2 composite: A potential 68Ge/68Ga generator column material. Appl Radiat Isot 2019;149:206- 13. [CrossRef]
  7. 7. Rosech F. Past, present and future of 68Ge/68Ga generators, Appl Radiat Isot. 2013;76:24-30. [CrossRef]
  8. 8. Chakraborty U, George CM, Lyndaker AM, Alani E. A. Delicate balance between repair and replication factors regulates recombination between divergent dna sequences in saccharomyces cerevisiae. Genetics 2016;202(2):525-40. [CrossRef]

Details

Primary Language

English

Subjects

Health Care Administration

Journal Section

Research Article

Publication Date

October 1, 2021

Submission Date

February 1, 2021

Acceptance Date

May 28, 2021

Published in Issue

Year 2021 Volume: 84 Number: 4

APA
Uğur, A., & Yüksel, D. (2021). EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY. Journal of Istanbul Faculty of Medicine, 84(4), 526-530. https://doi.org/10.26650/IUITFD.2021.872398
AMA
1.Uğur A, Yüksel D. EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY. İst Tıp Fak Derg. 2021;84(4):526-530. doi:10.26650/IUITFD.2021.872398
Chicago
Uğur, Ayşe, and Doğangün Yüksel. 2021. “EVALUATION OF 68Ge 68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY”. Journal of Istanbul Faculty of Medicine 84 (4): 526-30. https://doi.org/10.26650/IUITFD.2021.872398.
EndNote
Uğur A, Yüksel D (October 1, 2021) EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY. Journal of Istanbul Faculty of Medicine 84 4 526–530.
IEEE
[1]A. Uğur and D. Yüksel, “EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY”, İst Tıp Fak Derg, vol. 84, no. 4, pp. 526–530, Oct. 2021, doi: 10.26650/IUITFD.2021.872398.
ISNAD
Uğur, Ayşe - Yüksel, Doğangün. “EVALUATION OF 68Ge 68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY”. Journal of Istanbul Faculty of Medicine 84/4 (October 1, 2021): 526-530. https://doi.org/10.26650/IUITFD.2021.872398.
JAMA
1.Uğur A, Yüksel D. EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY. İst Tıp Fak Derg. 2021;84:526–530.
MLA
Uğur, Ayşe, and Doğangün Yüksel. “EVALUATION OF 68Ge 68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY”. Journal of Istanbul Faculty of Medicine, vol. 84, no. 4, Oct. 2021, pp. 526-30, doi:10.26650/IUITFD.2021.872398.
Vancouver
1.Ayşe Uğur, Doğangün Yüksel. EVALUATION OF 68Ge/68Ga GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF 68GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY. İst Tıp Fak Derg. 2021 Oct. 1;84(4):526-30. doi:10.26650/IUITFD.2021.872398

Contact information and address

Addressi: İ.Ü. İstanbul Tıp Fakültesi Dekanlığı, Turgut Özal Cad. 34093 Çapa, Fatih, İstanbul, TÜRKİYE

Email: itfdergisi@istanbul.edu.tr

Phone: +90 212 414 21 61