PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE
Abstract
The responsibility of power system is to ensure that adequate power generation with good quality and more economic power delivery to all consumers. Hence, proper control strategy is required to maintain a continuous power balance between power generation and surplus. So it is necessary to implement Automatic Generation control for more efficient control performance. In this paper , three area reheat thermal power is considered for the investigation and each generating unit equipped with either Single Reheat Turbine (SRT) or Double Reheat Turbine (DRH) with Proportional-Integral-Derivative(PID) controller. Optimal controller gain values are obtained using both conventional and Artificial Intelligence (AI) optimization technique. Finally, performances of AI-PID controller are compared with conventional optimized PID controller. Simulation result shows that contribution of AGC with AI PID controller more superior to conventional controller.
Keywords
References
- S.Banerjee, J.K.Chatterjee, S.C.Tripathy, “Application of
- magnetic energy storage unit as load-frequency stabilizer,” IEEE transactions on energy conversion, Vol. 5, pp. 46-51, 1990.
- S.C.Tripathy,R.Balasubramanian, P.S.Chandramohanan Nair
- “Small rating capacitive energy storage for dynamic performance improvement of automatic generation control,” IEE proceedings-C, vol.138, pp.1.3-111,1991.
- I.A.Chidambaram, B.Paramasivam, “Genetic algorithm based decentralized controllerfor
- load-frequency control of
- interconnected power systems with RFB considering TCPS
- in the tie-line,” International journal of electronic engineering
Details
Primary Language
English
Subjects
-
Journal Section
-
Publication Date
November 16, 2015
Submission Date
November 22, 2014
Acceptance Date
-
Published in Issue
Year 2015 Volume: 15 Number: 1
APA
Kaliannan, J., & Baskaran, A. (2015). PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. IU-Journal of Electrical & Electronics Engineering, 15(1), 1849-1854. https://izlik.org/JA44NK22EZ
AMA
1.Kaliannan J, Baskaran A. PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. IU-Journal of Electrical & Electronics Engineering. 2015;15(1):1849-1854. https://izlik.org/JA44NK22EZ
Chicago
Kaliannan, Jagaheesan, and Anand Baskaran. 2015. “PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE”. IU-Journal of Electrical & Electronics Engineering 15 (1): 1849-54. https://izlik.org/JA44NK22EZ.
EndNote
Kaliannan J, Baskaran A (November 1, 2015) PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. IU-Journal of Electrical & Electronics Engineering 15 1 1849–1854.
IEEE
[1]J. Kaliannan and A. Baskaran, “PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE”, IU-Journal of Electrical & Electronics Engineering, vol. 15, no. 1, pp. 1849–1854, Nov. 2015, [Online]. Available: https://izlik.org/JA44NK22EZ
ISNAD
Kaliannan, Jagaheesan - Baskaran, Anand. “PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE”. IU-Journal of Electrical & Electronics Engineering 15/1 (November 1, 2015): 1849-1854. https://izlik.org/JA44NK22EZ.
JAMA
1.Kaliannan J, Baskaran A. PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. IU-Journal of Electrical & Electronics Engineering. 2015;15:1849–1854.
MLA
Kaliannan, Jagaheesan, and Anand Baskaran. “PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE”. IU-Journal of Electrical & Electronics Engineering, vol. 15, no. 1, Nov. 2015, pp. 1849-54, https://izlik.org/JA44NK22EZ.
Vancouver
1.Jagaheesan Kaliannan, Anand Baskaran. PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. IU-Journal of Electrical & Electronics Engineering [Internet]. 2015 Nov. 1;15(1):1849-54. Available from: https://izlik.org/JA44NK22EZ