Abstract

In this paper, a new method for the improvement of the performance of magnetic filters for the removal of disperses mixtures with magnetic characteristics from industrial liquids and gases are investigated. In order to accelerate the reduction of the concentration of dispersed mixture, it is suggested that the intensity of the external magnetic field throughout the magnetic filter should be adjusted regionally. In order to achieve this goal, an intermediate control circuit with PWM (Pulse Width Modulation) driver capable of driving the external magnetic fields of magnetic filter regionally based on three regions was designed. The dsPIC30F2010 Digital Signal Controller (DSC; Microchip®) is used in the controller circuit. The experimental results shows that the concentration of dispersed magnetic mixture contained in the aqueous suspension passed from magnetic filter is reduced more efficiently. It is claimed that due to the adjustment of the external magnetic field intensity applied to the magnetic filters throughout the magnetic filter, the filter performance is increased, the electrical energy consumption is reduced, and the optimum design of magnetic filters is achieved.

Keywords

References

  1. J. Svoboda, “Magnetic Techniques for the Treatment of Minerals”, Kluwer Academic Publishers: Dordrecht, the Netherlands, 2004.
  2. J.H.P. Watson, “Magnetic Filtration”, J. Appl. Phys., vol. 44, no. 9, pp. 4209-4213, 1973.
  3. F. J. Friedlaender, R. R. Gerber, H.P., Henkel, et al., “Particle Build up on Single Spheres in HGMS”, IEEE Trans. Magn., vol. 17, no. 6, pp. 2804-2806, 1981.
  4. R. Gerber, R.R. Birss, “High Gradient Magnetic Separation”, John Wiley and Sons, New York, 1983.
  5. C. De Latour, “Magnetic separation in water pollution control”, IEEE Trans. Magn. vol. 9, no. 3, pp. 314-316, 1973.
  6. C. Tsouris, J. Noonan, T.Y. Ying, S. Yiacomi, “Surfactant effects on the mechanism of particle capture in high-gradient magnetic filtration”, Sep. Purify. Technol. vol. 51, no. 2, pp. 201–209, 2006.
  7. Sh.-J. Bai, Sh.-M. Wen, D.-W. Liu, W.-B. Zhang, “Separation of phosphorous and magnetic mineral fines from siderite reductive ore by applying magnetic flocculation”, Separation Science and Technology, vol. 49, no. 9, pp. 1434-1441, 2014.
  8. A.V. Sandulyak, “Magnetic Filtration of Liquids and Gases”, Chemics, Ed. Moscow, 1998.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Authors

Ömerül Faruk Özgüven
INONU UNIV
Türkiye

Publication Date

March 27, 2017

Submission Date

February 7, 2017

Acceptance Date

-

Published in Issue

Year 2017 Volume: 17 Number: 1

APA
Özgüven, Ö. F. (2017). IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER. IU-Journal of Electrical & Electronics Engineering, 17(1), 3283-3293. https://izlik.org/JA33RT84NB
AMA
1.Özgüven ÖF. IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER. IU-Journal of Electrical & Electronics Engineering. 2017;17(1):3283-3293. https://izlik.org/JA33RT84NB
Chicago
Özgüven, Ömerül Faruk. 2017. “IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER”. IU-Journal of Electrical & Electronics Engineering 17 (1): 3283-93. https://izlik.org/JA33RT84NB.
EndNote
Özgüven ÖF (March 1, 2017) IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER. IU-Journal of Electrical & Electronics Engineering 17 1 3283–3293.
IEEE
[1]Ö. F. Özgüven, “IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER”, IU-Journal of Electrical & Electronics Engineering, vol. 17, no. 1, pp. 3283–3293, Mar. 2017, [Online]. Available: https://izlik.org/JA33RT84NB
ISNAD
Özgüven, Ömerül Faruk. “IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER”. IU-Journal of Electrical & Electronics Engineering 17/1 (March 1, 2017): 3283-3293. https://izlik.org/JA33RT84NB.
JAMA
1.Özgüven ÖF. IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER. IU-Journal of Electrical & Electronics Engineering. 2017;17:3283–3293.
MLA
Özgüven, Ömerül Faruk. “IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER”. IU-Journal of Electrical & Electronics Engineering, vol. 17, no. 1, Mar. 2017, pp. 3283-9, https://izlik.org/JA33RT84NB.
Vancouver
1.Ömerül Faruk Özgüven. IMPROVEMENT OF MAGNETIC FILTERS’ PERFORMANCE BY CONTROLLING REGIONAL FIELD WITH PWM USING A DIGITAL SIGNAL CONTROLLER. IU-Journal of Electrical & Electronics Engineering [Internet]. 2017 Mar. 1;17(1):3283-9. Available from: https://izlik.org/JA33RT84NB