BibTex RIS Cite
Year 2006, Volume: 6 Issue: 1, 53 - 59, 02.01.2012

Abstract

References

  • Ahmad, M., M. S. Yusuf, M. Z. Chowdhury, and M. Yamada, “Global optimization of optical flow technique on the computation of tissue-motion in neonatal cranial ultrasonogram,” Electronic Engineering, Istanbul university, vol. , no. 1, pp. 1007-1016, 2004.
  • Kearney, J. K. , W. B. Thompson, and D. L. Analysis of Gradient-Based Methods with Local Optimization,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 9, pp. 244, March 1987.
  • Fukazawa, M., H. Kubo, Y. Kitsunezuka, and M. Yamada, 1999, “Motion analysis of artery pulsation in neonatal cranial ultrasonogram,” SPIE, vol. 3661.
  • Kitsunezuka, Y., and H. Nakamura, “Syonika-Rinsyo,” no. 38, pp. 297-308 [in Japanese], 1985.
  • Press, W. H., Saul A. Teukolsky, William T. Vetterling and Brian P. Flannery, “Numerical Recipes in C: The art of Scientific Computing”, Second Edition, Cambridge University press. ultrasonogram,” Jpn. J. Appl. Physics. 37, pp. 1178, 1998.
  • Yamada, M., M. Fukuzawa, Y. Kitsunezuka, J. Kishida, N. Nakamori, H. Kanamori, T. Sakurai and S. Kodama, “Pulsation detection from noisy ultrasound echo moving images of newborn baby head using Fourier transform,” Jpn. J. Appl. Phys., Vol. 34, p. 2854-2856, 1995.

TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY

Year 2006, Volume: 6 Issue: 1, 53 - 59, 02.01.2012

Abstract

Tissue-motion is an important physical parameter that can be considered in discussing the strength of artery pulsation of newborn baby for pediatrics diagnosis. In this paper, we have used optical flow technique to determine the tissue-motion velocity quantitatively in cranial ultrasonogram of newborn baby. We have estimated the tissue-motion by using gradient-based optical flow method and then the time variant tissue motion velocities are analyzed by using Fourier transform. Strong pulsation is observed in the harmonic frequency of tissue-motion that has a relation to the heartbeat frequency of a newborn baby.

References

  • Ahmad, M., M. S. Yusuf, M. Z. Chowdhury, and M. Yamada, “Global optimization of optical flow technique on the computation of tissue-motion in neonatal cranial ultrasonogram,” Electronic Engineering, Istanbul university, vol. , no. 1, pp. 1007-1016, 2004.
  • Kearney, J. K. , W. B. Thompson, and D. L. Analysis of Gradient-Based Methods with Local Optimization,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 9, pp. 244, March 1987.
  • Fukazawa, M., H. Kubo, Y. Kitsunezuka, and M. Yamada, 1999, “Motion analysis of artery pulsation in neonatal cranial ultrasonogram,” SPIE, vol. 3661.
  • Kitsunezuka, Y., and H. Nakamura, “Syonika-Rinsyo,” no. 38, pp. 297-308 [in Japanese], 1985.
  • Press, W. H., Saul A. Teukolsky, William T. Vetterling and Brian P. Flannery, “Numerical Recipes in C: The art of Scientific Computing”, Second Edition, Cambridge University press. ultrasonogram,” Jpn. J. Appl. Physics. 37, pp. 1178, 1998.
  • Yamada, M., M. Fukuzawa, Y. Kitsunezuka, J. Kishida, N. Nakamori, H. Kanamori, T. Sakurai and S. Kodama, “Pulsation detection from noisy ultrasound echo moving images of newborn baby head using Fourier transform,” Jpn. J. Appl. Phys., Vol. 34, p. 2854-2856, 1995.
There are 6 citations in total.

Details

Primary Language English
Journal Section Articles
Authors

Mohiuddin Ahmad This is me

Mostafa Zaman Chowdhury This is me

Md. Jahangir Alam This is me

Publication Date January 2, 2012
Published in Issue Year 2006 Volume: 6 Issue: 1

Cite

APA Ahmad, M., Chowdhury, M. Z., & Alam, M. J. (2012). TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering, 6(1), 53-59.
AMA Ahmad M, Chowdhury MZ, Alam MJ. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering. January 2012;6(1):53-59.
Chicago Ahmad, Mohiuddin, Mostafa Zaman Chowdhury, and Md. Jahangir Alam. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering 6, no. 1 (January 2012): 53-59.
EndNote Ahmad M, Chowdhury MZ, Alam MJ (January 1, 2012) TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering 6 1 53–59.
IEEE M. Ahmad, M. Z. Chowdhury, and M. J. Alam, “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”, IU-Journal of Electrical & Electronics Engineering, vol. 6, no. 1, pp. 53–59, 2012.
ISNAD Ahmad, Mohiuddin et al. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering 6/1 (January 2012), 53-59.
JAMA Ahmad M, Chowdhury MZ, Alam MJ. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering. 2012;6:53–59.
MLA Ahmad, Mohiuddin et al. “TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY”. IU-Journal of Electrical & Electronics Engineering, vol. 6, no. 1, 2012, pp. 53-59.
Vancouver Ahmad M, Chowdhury MZ, Alam MJ. TISSUE-MOTION ANALYSIS OF ARTERY PULSATION IN CRANIAL ULTRASONOGRAM OF NEWBORN BABY. IU-Journal of Electrical & Electronics Engineering. 2012;6(1):53-9.