Research Article

Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products

Volume: 55 Number: 2 September 23, 2025
EN

Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products

Abstract

Background and Aims: Compounds of low-molecular-weight cyclic volatile dimethylsiloxane (cVMS) are widely used in per sonal care products due to their beneficial properties for consumer goods. However, the European Chemicals Agency (ECHA) has proposed restrictions on two cyclic siloxanes, octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5), in rinse-off Personal care products that are rinsed off and discharged into drains. The main concerns with D4 and D5 are their persistence and accumulation in the water bodies. The goal of this restriction is to reduce their discharge into surface waters. According to the ECHA, these substances should not be sold or used in concentrations of 0.1% or more by weight in rinse-off personal care products. Analysing cyclic siloxanes in these products is vital for understanding human exposure to these substances. ECHA mandates dependable analytical methods for manufacturers and government agencies to verify adherence to the restrictions. A simple, fast, and easily applicable extraction method using gas chromatography mass spectrometry (GC-MS) for the precise measurement of D4 at around 0.1% by weight of the total formulation in personal care products (PCPs) is proposed in this article. Methods: Detection was performed using a GC-MS instrument equipped with an electron impact (EI) ion source and operated using the selected ion monitoring (SIM) mode. The mass-to-charge ratios (m/z) monitored for D4 were 281.0, 282.0, and 283.0. The monitored mass-to-charge ratios (m/z) for D4 were 281.0, 282.0, and 283.0. Results: The proposed method showed excellent linearity, with a coefficient of determination (r²) exceeding 0.999. The limit of detection (LOD) and limit of quantification (LOQ) were 0.2320 μg/mL and 0.7735 μg/mL, respectively. The precision and accuracy of D4 were evaluated at concentrations of 3.0 µg/mL, 15.0 µg/mL, and 25.0 µg/mL. The coefficients of variation (CV) were 5.07%, 7.24%, and 4.95%, respectively, while the accuracy values were 103.17±0.16, 100.44±1.09, and 101.13±0.07, respectively, for these concentrations. These values are within the acceptable limit of ±15%. The results show that this GC MS method meets the regulatory standards and demonstrates satisfactory accuracy and precision. Real samples, such as beard oil and hair conditioner, were successfully analysed using this method. Conclusion: The developed GC-MS method provides a simple, accurate, and sensitive approach for detecting D4 in rinse-off personal care products. It meets regulatory requirements and is suitable for routine analysis, supporting efforts to control environmental exposure to cyclic siloxanes.

Keywords

References

  1. Aspromonte J., Giacoppo G., Wolfs K., & Adams E. (2020). Headspace gas chromatography for the determination of volatile methylsiloxanes in personal care products. Analytical and Bioanalytical Chemistry, 412(11), 2537–2544. https:// doi.org/10.1007/s00216-020-02478-y. google scholar
  2. Biesterbos J. W., Beckmann G., Anzion R. B., Ragas A. M., Russel F. G., & Scheepers P. T. (2014). Sensitive method for quantification of octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in end-exhaled air by thermal desorption gas chromatography mass spectrometry. Analytical Chemistry, 86(12), 5794–5799. https://doi.org/10.1021/ac5004695. google scholar
  3. bin Abdullaha A. F. L., Marimuthua Y., Hawa C. K., Fatihah N., Yaacoba H., & Hooic Y. C. (2011). Forensic discrimination of lipsticks by thin layer chromatography and gas chromatography-mass spectrometry. Malaysian Journal of Forensic Sci, 2(1), 22-28. google scholar
  4. Brothers Jr H. M. Bovens E., Bruni A., Habitz T. M., Hamachi T., Han Y., & Tecklenburg Jr R. E. (2016). A practical gas chromatography flame ionization detection method for the determination of octamethylcyclotetrasiloxane, decamethylcyclopentasiloxane, and dodecamethylcyclohexasiloxane in silicone emulsions. Journal of Chromatography A, 1441, 116-125. 10.1016/j.chroma.2016.02.069. google scholar
  5. Brothers Jr H. M., Boehmer T., Campbell R. A., Dorn S., Kerbleski J. J., Lewis S., Mund C., Pero D., Saito K., Wieser M., & Zoller W. (2017). Determination of cyclic volatile methylsiloxanes in personal care products by gas chromatography. Interna- tional Journal of Cosmetic Science, 39(6), 580–588.https://doi.org/10.1111/ics. 12411 google scholar
  6. Capela D., Homem V., Alves A., & Santos L. (2018). Reply to comments on “volatile methylsiloxanes in personal care products–Using QuEChERS as a “green” analytical approach” Talanta, 174, 156–157. https://doi.org/10.1016/j.talanta.2017. 11.023 google scholar
  7. Dekant W., Scialli A. R., Plotzke K., & Klaunig J. E. (2017). Biological relevance of effects following chronic administration of octamethylcyclotetrasiloxane (D4) in Fischer 344 rats. Toxicology letters, 279 (1), 42–53. https://doi.org/10.1016/j. toxlet.2017.01.010. google scholar
  8. European Commission Scientific Committee on Consumer Safety, Opinion on Cyclomethicone Octamethylcyclotetrasiloxane (Cyclotetrasiloxane, D4) and Decamethylcyclopentasiloxane (Cyclopentasiloxane, D5). Report No. SCCS/1241/10. google scholar

Details

Primary Language

English

Subjects

Pharmaceutical Analytical Chemistry

Journal Section

Research Article

Publication Date

September 23, 2025

Submission Date

July 12, 2024

Acceptance Date

February 12, 2025

Published in Issue

Year 2025 Volume: 55 Number: 2

APA
Neşetoğlu, N., Özdemir, E., Ergün, B., & Ünal, D. Ö. (2025). Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products. İstanbul Journal of Pharmacy, 55(2), 260-266. https://doi.org/10.26650/IstanbulJPharm.2025.1515130
AMA
1.Neşetoğlu N, Özdemir E, Ergün B, Ünal DÖ. Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products. iujp. 2025;55(2):260-266. doi:10.26650/IstanbulJPharm.2025.1515130
Chicago
Neşetoğlu, Neşet, Elif Özdemir, Barkın Ergün, and Durişehvar Özer Ünal. 2025. “Gas Chromatography-Mass Spectrometry (GC-MS) Was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products”. İstanbul Journal of Pharmacy 55 (2): 260-66. https://doi.org/10.26650/IstanbulJPharm.2025.1515130.
EndNote
Neşetoğlu N, Özdemir E, Ergün B, Ünal DÖ (September 1, 2025) Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products. İstanbul Journal of Pharmacy 55 2 260–266.
IEEE
[1]N. Neşetoğlu, E. Özdemir, B. Ergün, and D. Ö. Ünal, “Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products”, iujp, vol. 55, no. 2, pp. 260–266, Sept. 2025, doi: 10.26650/IstanbulJPharm.2025.1515130.
ISNAD
Neşetoğlu, Neşet - Özdemir, Elif - Ergün, Barkın - Ünal, Durişehvar Özer. “Gas Chromatography-Mass Spectrometry (GC-MS) Was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products”. İstanbul Journal of Pharmacy 55/2 (September 1, 2025): 260-266. https://doi.org/10.26650/IstanbulJPharm.2025.1515130.
JAMA
1.Neşetoğlu N, Özdemir E, Ergün B, Ünal DÖ. Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products. iujp. 2025;55:260–266.
MLA
Neşetoğlu, Neşet, et al. “Gas Chromatography-Mass Spectrometry (GC-MS) Was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products”. İstanbul Journal of Pharmacy, vol. 55, no. 2, Sept. 2025, pp. 260-6, doi:10.26650/IstanbulJPharm.2025.1515130.
Vancouver
1.Neşet Neşetoğlu, Elif Özdemir, Barkın Ergün, Durişehvar Özer Ünal. Gas Chromatography-Mass Spectrometry (GC-MS) was Used for The Determination of Cyclic Volatile Dimethylsiloxane (D4) in Personal Care Products. iujp. 2025 Sep. 1;55(2):260-6. doi:10.26650/IstanbulJPharm.2025.1515130