Research Article

Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome

Volume: 50 Number: 1 April 1, 2020
  • Merve Keşkek Arslan *
  • Durişehvar Özer Ünal
EN

Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome

Abstract

Background and Aims: The combination of troxerutin and carbazochrome has been found efficacious for non-surgical patients with acute uncomplicated hemorrhoids. Therefore it is essential to develop a simultaneous analysis method of those drug substances. This study explains a simple and selective HPLC method to analyze troxerutin and carbazohrome in tablets. Methods: The analysis was carried out using a core-shell pentafluorophenyl propyl polar column with a mobile phase consisting of (MeOH; % 5 HAc), (99.5:0.5 - V/V) at a flow rate of 0.25 mL/min. UV detection was set to 350 nm. Results: The standard calibration curve was established between 1.00-20.00 μg/mL for troxerutin; 0.05-1.00 μg/mL for carbazochrome. LOD and LOQ were found to be 0.65 μg/mL and 1.00 μg/mL for troxerutin and 0.01 μg/mL and 0.05 μg/mL for carbazochrome, respectively. Conclusion: The proposed method was validated for specificity, linearity, accuracy, precision, LOQ and LOD and then successfully applied for the analysis of these substances in tablets.

Keywords

References

  1. • Abdelrahman, M. M., Abdelaleem, E. A., Ali, N. W., & Emam, R. A. (2016). Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods. Bulletin of Faculty of Pharmacy, Cairo University, 54(1), 67–75.
  2. • Basile, M., Gidaro, S., Pacella, M., Biffignandi, P. M., & Gidaro, G. S. (2001). Parenteral troxerutin and carbazochrome combination in the treatment of post-hemorrhoidectomy status: A randomized, double-blind, placebo-controlled, phase IV study. Current Medical Research and Opinion, 17(4), 256–261.
  3. • Chen, Y. H., Ren, K.,Tian F. S., Zhu, K. K., & Hu, X. Y. (2015). Spectrofluorimetric and spectrophotometric determination of troxerutin in pharmaceutical preparations. Asian Journal of Chemıstry, 27(5), 1854–1856.
  4. • Cui, X., Zhang, M., Guan, X., Yin, L., Sun, Y., Fawcett, J. P., & Gu, J. (2011). LC–MS–MS determination of troxerutin in plasma and its application to a pharmacokinetic study. Chromatographia, 73(1), 165–169.
  5. • European Medicines Agency. (1995). ICH Q2 (R1) validation of analytical procedures: Text and methodology. Retrieved from https://www. ema.europa.eu/documents/scientific-guideline/ich-q-2-r1-validation-analytical-procedures-text-methodology-step-5_en.pdf
  6. • European Medicines Agency. (2011). Guideline on bioanalytical method validation. Retrived from https://www.ema.europa.eu/ en/documents/scientific-guideline/guideline-bioanalyticalmethod-validation_en.pdf
  7. • Gan, X., Liu, S., Liu, Z., Hu, X., Cui, Z., & Wang, Y. (2012). Determination of carbazochrome by fluorescence quenching method. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 97, 161–166.
  8. • Guo, H-Z., Ron, C., Bı, K-S., & Sun, Y-Q. (2004). Determination of troxerutin in venoruton injections and venoruton tabletsby short capillary zone electrophoresis. Chinese Journal of Pharmaceutical Analysis, 24(5), 457–459.

Details

Primary Language

English

Subjects

Pharmacology and Pharmaceutical Sciences, Health Care Administration

Journal Section

Research Article

Authors

Merve Keşkek Arslan * This is me
0000-0002-5758-9528
Türkiye

Durişehvar Özer Ünal This is me
0000-0003-0754-1240
Türkiye

Publication Date

April 1, 2020

Submission Date

March 6, 2019

Acceptance Date

December 3, 2019

Published in Issue

Year 2020 Volume: 50 Number: 1

APA
Keşkek Arslan, M., & Özer Ünal, D. (2020). Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome. İstanbul Journal of Pharmacy, 50(1), 16-20. https://izlik.org/JA46RE67XJ
AMA
1.Keşkek Arslan M, Özer Ünal D. Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome. iujp. 2020;50(1):16-20. https://izlik.org/JA46RE67XJ
Chicago
Keşkek Arslan, Merve, and Durişehvar Özer Ünal. 2020. “Core Shell Column in High-Performance Liquid Chromatography for the Determination of Polar Compounds; Troxerutin and Carbazochrome”. İstanbul Journal of Pharmacy 50 (1): 16-20. https://izlik.org/JA46RE67XJ.
EndNote
Keşkek Arslan M, Özer Ünal D (April 1, 2020) Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome. İstanbul Journal of Pharmacy 50 1 16–20.
IEEE
[1]M. Keşkek Arslan and D. Özer Ünal, “Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome”, iujp, vol. 50, no. 1, pp. 16–20, Apr. 2020, [Online]. Available: https://izlik.org/JA46RE67XJ
ISNAD
Keşkek Arslan, Merve - Özer Ünal, Durişehvar. “Core Shell Column in High-Performance Liquid Chromatography for the Determination of Polar Compounds; Troxerutin and Carbazochrome”. İstanbul Journal of Pharmacy 50/1 (April 1, 2020): 16-20. https://izlik.org/JA46RE67XJ.
JAMA
1.Keşkek Arslan M, Özer Ünal D. Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome. iujp. 2020;50:16–20.
MLA
Keşkek Arslan, Merve, and Durişehvar Özer Ünal. “Core Shell Column in High-Performance Liquid Chromatography for the Determination of Polar Compounds; Troxerutin and Carbazochrome”. İstanbul Journal of Pharmacy, vol. 50, no. 1, Apr. 2020, pp. 16-20, https://izlik.org/JA46RE67XJ.
Vancouver
1.Merve Keşkek Arslan, Durişehvar Özer Ünal. Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome. iujp [Internet]. 2020 Apr. 1;50(1):16-20. Available from: https://izlik.org/JA46RE67XJ