The effect of stopping power ratios of different protocols on %DD curve

Year 2009, Volume: 24 Issue: 1, 15 - 20, 01.02.2009

Abstract

OBJECTIVES The effects of the stopping power ratios of different protocols on %DD curve were investigated in this study. METHODS Percentage ionization curve was measured at SSD=95 cm using 10x10 standard cone and 6, 8, 10, 12, 15 and 18 MeV electron energies. Stopping power ratios at each depth were determined as recommended by the three protocols. %DD curves were then found and compared. The stopping power ratios of the different protocols were determined and plotted against R50. RESULTS The stopping power ratios of the different protocols did have an effect on %DD curves. The clearest difference was seen at the surface. The maximum difference was 1.45% at 10 MeV, while the minimum difference was 0.09% at 6 MeV. CONCLUSION Stopping power ratios as found using realistic electron beams provide more accurate surface doses, as reported in the literature.

References

  • 1. International Atomic Energy Agency ‘The use of plane parallel ionization chambers in high energy electron and photon beams: an international code of practice for dosimetry.’ Tecnical Reports Series No.381 Vienna, Austria: 1997.
  • 2. International Atomic Energy Agency ‘Absorbe dose determination in photon and electron beams: an international code of practice.’ Tecnical Reports Series No.277, Vienna, Austria: 1987.
  • 3. International Atomic Energy Agency ‘Absorbe dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbe dose to water.’ Tecnical Reports Series No.398 Vienna, Austria: 2000.
  • 4. Andreo P, Huq MS, Westermark M, Song H, Tilikidis A, DeWerd L, et al. Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. International Atomic Energ y Agency.Phys Med Biol 2002;47(17):3033-53.
  • 5. Ding GX, Yu CW. Determination of percentage depthdose curves for electron beams using different types of detectors. Med Phys 2001;28(3):298-302.

Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi

Year 2009, Volume: 24 Issue: 1, 15 - 20, 01.02.2009

Abstract

AMAÇ Bu çalışmada, farklı SW, HAVA'ların %DD eğrilerine yaptığı etki araştırıldı. GEREÇ VE YÖNTEM Lineer hızlandırıcı cihazında 6, 8, 10, 12, 15 ve 18 MeV elektron enerjilerinde, SSD 95 cm'de 10x10 cm standart elektron konu için yüzde iyonizasyon değerleri ölçüldü. Her derinlik için durdurma gücü oranları üç protokolün belirttiği şekilde bulundu ve bu değerler yüzde iyonizasyon değerleri ile çarpılarak yüzde derin doz grafiği elde edildi. Üç protokolden elde edilen grafikler birbirleri ile karşılaştırıldı. Ayrıca farklı protokoller için bulunan durdurma gücü oranları birbirleri ile kıyaslanarak R50 karşı grafikleri çizildi. BULGULAR Kullanılan farklı durdurma gücü oranlarının yüzde derin doz eğrilerinde farklılıklara neden olduğu görülmüştür. En fazla değişim yüzey dozlarında meydana gelmiştir. En büyük fark 10 MeV enerjisinde E0'a göre hesaplanmış TRS 381/TRS 277 farkı %1, 45'dir. En az fark ise 6 MeV enerjisinde RP'ye göre hesaplanmış TRS 398/TRS 277 farkı %0, 09'dur. SONUÇ Realistik elektron demetleri için bulunmuş durdurma gücü oranlarını kullanmak literatürlerde de belirtildiği gibi yüzey dozlarını daha doğru şekilde değerlendirmemizi sağlamaktadır.

References

  • 1. International Atomic Energy Agency ‘The use of plane parallel ionization chambers in high energy electron and photon beams: an international code of practice for dosimetry.’ Tecnical Reports Series No.381 Vienna, Austria: 1997.
  • 2. International Atomic Energy Agency ‘Absorbe dose determination in photon and electron beams: an international code of practice.’ Tecnical Reports Series No.277, Vienna, Austria: 1987.
  • 3. International Atomic Energy Agency ‘Absorbe dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbe dose to water.’ Tecnical Reports Series No.398 Vienna, Austria: 2000.
  • 4. Andreo P, Huq MS, Westermark M, Song H, Tilikidis A, DeWerd L, et al. Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. International Atomic Energ y Agency.Phys Med Biol 2002;47(17):3033-53.
  • 5. Ding GX, Yu CW. Determination of percentage depthdose curves for electron beams using different types of detectors. Med Phys 2001;28(3):298-302.
There are 5 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Hilal Acar This is me

Publication Date February 1, 2009
Published in Issue Year 2009 Volume: 24 Issue: 1

Cite

APA Acar, H. (2009). Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi. Türk Onkoloji Dergisi, 24(1), 15-20.
AMA Acar H. Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi. Türk Onkoloji Dergisi. February 2009;24(1):15-20.
Chicago Acar, Hilal. “Farklı Protokollerdeki Durdurma gücü oranlarının %DD eğrisine Etkisi”. Türk Onkoloji Dergisi 24, no. 1 (February 2009): 15-20.
EndNote Acar H (February 1, 2009) Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi. Türk Onkoloji Dergisi 24 1 15–20.
IEEE H. Acar, “Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi”, Türk Onkoloji Dergisi, vol. 24, no. 1, pp. 15–20, 2009.
ISNAD Acar, Hilal. “Farklı Protokollerdeki Durdurma gücü oranlarının %DD eğrisine Etkisi”. Türk Onkoloji Dergisi 24/1 (February 2009), 15-20.
JAMA Acar H. Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi. Türk Onkoloji Dergisi. 2009;24:15–20.
MLA Acar, Hilal. “Farklı Protokollerdeki Durdurma gücü oranlarının %DD eğrisine Etkisi”. Türk Onkoloji Dergisi, vol. 24, no. 1, 2009, pp. 15-20.
Vancouver Acar H. Farklı protokollerdeki durdurma gücü oranlarının %DD eğrisine etkisi. Türk Onkoloji Dergisi. 2009;24(1):15-20.