Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep

Volume: 42 Number: 1 August 11, 2015
  • Javad Tajık
  • Amir Samımı
  • Saeedeh Shojaeepour
  • Sajad Jarakanı
TR EN

Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep

Abstract

The normal electrocardiographic (ECG) parameters in the base-apex lead were evaluated in 40 clinically healthy Kermani sheep, and compared between sexes and three age groups. The heart rate varied from 83-192 beats/min with a mean of 128.9±4.7 beats/min (Mean±SEM). Sinus arrhythmia was the only observed cardiac dysrhythmia on the ECG traces diagnosed in 45% of animals. No significant difference was found in heart rate, amplitude, and duration of ECG waves and intervals between two sexes. Nevertheless, the heart rate, amplitude of ECG waves, duration of T waves and duration of P-R, Q-T and R-R intervals showed significant difference between the age groups. This study provides information on the cardiac rhythm, heart rate, duration, and amplitude of ECG deflections in Kermani sheep. We proposed the base-apex lead as a suitable lead for ECG evaluation in this species.

Keywords

References

  1. Alidadi, N., Mokhber-Dezfouli, M.R., Nadalian, M.G., Rezakhani, A., Nourozian, I., 2002. The ECG of the Turkman horse using the standard lead base apex. Journal of Equine Veterinary Science 22 (5), 182-184.
  2. Barazandeh, A., MolaeiMoghbeli, S., Vatankhah, M., GhaviHossein-Zadeh, N., 2012. Lamb survival analysis from birth to weaning in Iranian Kermani sheep. Tropical Animal Health and Production 44 (4), 929– 934.
  3. Deroth, L., 1980. Electrocardiographic parameters in normal lactating Holstein cow. Canadian Veterinary Journal 21 (10), 271-277.
  4. Escudero, A., Gonzalez, J.R., Benedito, J.L., Prieto, F.R., Ayala, I., 2009. Electrocardigraphic parameters in the clinically healthy Zamorano-leones donkey. Research in Veterinary Science 87 (3), 458-61.
  5. Khaldari, M., 2003. Sheep and Goat Husbandry. Tehran University, pp. 75-101.
  6. Mohan, N.H., Niyogi, D., Singh, H.N., 2005. Analysis of normal electrocardiograms of Jamunapari goats. Journal of Veterinary Science 6 (4), 295-298.
  7. Physick-Sheard, P.W., Hendren, C.M., 1998. Heart Score: Physiological Basis and Confounding Variables. In Snow D.H., Persson S.G.B., Rose R.J. (eds.), Equine Exercise Physiology, Cambridge: Burlington Press, pp.121-134.
  8. Radostits, O. M., C. C. Gay, K. W. Hinchcliff, P. D. Constable, 2007. Diseases of the Cardiovascular System. In: Veterinary Medicine: A Textbook of the Diseases of Cattle, Horses, Sheep, Pigs and Goats, 10th edn, Elsevier, pp. 14, 399-438. Rezakhani, A., Khajedehi, G.R., 2001. of goat. electrocardiographic Pajouhesh va Sazandegi 14, 102-103. the

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Javad Tajık This is me

Amir Samımı This is me

Saeedeh Shojaeepour This is me

Sajad Jarakanı This is me

Publication Date

August 11, 2015

Submission Date

November 20, 2015

Acceptance Date

-

Published in Issue

Year 2016 Volume: 42 Number: 1

APA
Tajık, J., Samımı, A., Shojaeepour, S., & Jarakanı, S. (2015). Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep. İstanbul Üniversitesi Veteriner Fakültesi Dergisi, 42(1), 74-79. https://doi.org/10.16988/iuvfd.2016.77664
AMA
1.Tajık J, Samımı A, Shojaeepour S, Jarakanı S. Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep. iuvfd. 2015;42(1):74-79. doi:10.16988/iuvfd.2016.77664
Chicago
Tajık, Javad, Amir Samımı, Saeedeh Shojaeepour, and Sajad Jarakanı. 2015. “Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep”. İstanbul Üniversitesi Veteriner Fakültesi Dergisi 42 (1): 74-79. https://doi.org/10.16988/iuvfd.2016.77664.
EndNote
Tajık J, Samımı A, Shojaeepour S, Jarakanı S (August 1, 2015) Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep. İstanbul Üniversitesi Veteriner Fakültesi Dergisi 42 1 74–79.
IEEE
[1]J. Tajık, A. Samımı, S. Shojaeepour, and S. Jarakanı, “Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep”, iuvfd, vol. 42, no. 1, pp. 74–79, Aug. 2015, doi: 10.16988/iuvfd.2016.77664.
ISNAD
Tajık, Javad - Samımı, Amir - Shojaeepour, Saeedeh - Jarakanı, Sajad. “Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep”. İstanbul Üniversitesi Veteriner Fakültesi Dergisi 42/1 (August 1, 2015): 74-79. https://doi.org/10.16988/iuvfd.2016.77664.
JAMA
1.Tajık J, Samımı A, Shojaeepour S, Jarakanı S. Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep. iuvfd. 2015;42:74–79.
MLA
Tajık, Javad, et al. “Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep”. İstanbul Üniversitesi Veteriner Fakültesi Dergisi, vol. 42, no. 1, Aug. 2015, pp. 74-79, doi:10.16988/iuvfd.2016.77664.
Vancouver
1.Javad Tajık, Amir Samımı, Saeedeh Shojaeepour, Sajad Jarakanı. Analysis of Base-Apex Lead Electrocardiogram in Clinically Healthy Kermani Sheep. iuvfd. 2015 Aug. 1;42(1):74-9. doi:10.16988/iuvfd.2016.77664