Research Article

Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator

Number: 32 September 30, 2020
Elif Sarıkaya , Melek Gökbulut *, Gulhan Guler , Halis Bozkurt , İbrahim Yiğitoğlu , Arzu Coşkun
EN

Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator

Abstract

The amount of the beam emitted from linear accelerators can be adjusted by changing the jaw intervals of multi leaf collimator (MLC) system. The area to which the beam will be delivered is determined. In this study, the jaw intervals of linear accelerator in the Oncology unit of the Tokat Gaziosmanpaşa University Faculty of Medicine have been determined as 4 x 4 cm2 and 10 x 10 cm2 and the radiation dose emitted for both conditions has measured. The results have compared with other studies in the literature.

Keywords

Linear accelerators,Jaw intervals

References

  1. P. Mayles, A. Nahum, J. C. Rosenwald, Handbook of Radiotherapy Physics: Theory and Practice, United States of America: Taylor and Francis Group, LLC, 2007.
  2. C. J. Karzmark, R. J. Morton, A Primer on Theory and Operation of Linear Accelerators in Radiation Therapy, Wisconsin: Medical Physics Publishing, Inc.4555 Helgesen Drive, Second edition, 1998.
  3. W. R. Lutz, R. D. Larsen, B. E. Bjarngard, Beam Alignment Test for Therapy Accelerators, International Journal of Radiation Oncology Biology Physics 7 (1981) 1727-1731.
  4. C. J. Karzmark, Advance in Linear Accelerator Design for Radiotherapy, Medical Physics 11(2) (1984) 105-128.
  5. A. Boyer, P. Biggs, J. Galvin, E. Klein, T. LoSasso, D. Low, K. Mah, C. Yu, Basic Applications of Multileaf Collimators, Madison: American Association of Physicists in Medicine by Medical Physics Publishing Report No. 72, 2001.
  6. C. S. Chui, S. Spirou, T. LoSasso, Testing of Dynamic Multi-Leaf Collimation, Medical Physics 23(5) (1996) 635-641.
  7. S. V. Spirou, C. S. Chui, Generation of Arbitrary Intensity Profiles by Dynamic Jaws or Multileaf Collimators, Medical Physics 21 (1994) 1031-1041.
  8. J. H. Mott, A. R. Hounsell, G. J. Budgell, J. M. Wilkinson, P. C Williams, Customised Compensation Using Intensity Modulated Beams Delivered by Dynamic Multileaf Collimation, Radiotherapy and Oncology 53 (1999) 59-65.
  9. G. Aydın, Temel ve Klinik Radyoterapi, Temel Radyoterapi Fiziği I, İzmir: Hürriyet Matbaa (2013) 39-42.
  10. M. Bakhtiari, L. Kumaraswamy, D. W. Bailey, S. de Boer, H. K. Malhotra, M. B. Podgorsak, Using an EPID for Patient-Specific VMAT Quality Assurance, Medical Physics 38(3) (2011) 1366-1373.
APA
Sarıkaya, E., Gökbulut, M., Guler, G., Bozkurt, H., Yiğitoğlu, İ., & Coşkun, A. (2020). Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator. Journal of New Theory, 32, 15-20. https://izlik.org/JA63MS37LK
AMA
1.Sarıkaya E, Gökbulut M, Guler G, Bozkurt H, Yiğitoğlu İ, Coşkun A. Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator. JNT. 2020;(32):15-20. https://izlik.org/JA63MS37LK
Chicago
Sarıkaya, Elif, Melek Gökbulut, Gulhan Guler, Halis Bozkurt, İbrahim Yiğitoğlu, and Arzu Coşkun. 2020. “Measurement of Radiation Dose Emitted by 4 X 4 Cm2 and 10 X 10 Cm2 Aperture of Linear Accelerator”. Journal of New Theory, nos. 32: 15-20. https://izlik.org/JA63MS37LK.
EndNote
Sarıkaya E, Gökbulut M, Guler G, Bozkurt H, Yiğitoğlu İ, Coşkun A (September 1, 2020) Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator. Journal of New Theory 32 15–20.
IEEE
[1]E. Sarıkaya, M. Gökbulut, G. Guler, H. Bozkurt, İ. Yiğitoğlu, and A. Coşkun, “Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator”, JNT, no. 32, pp. 15–20, Sept. 2020, [Online]. Available: https://izlik.org/JA63MS37LK
ISNAD
Sarıkaya, Elif - Gökbulut, Melek - Guler, Gulhan - Bozkurt, Halis - Yiğitoğlu, İbrahim - Coşkun, Arzu. “Measurement of Radiation Dose Emitted by 4 X 4 Cm2 and 10 X 10 Cm2 Aperture of Linear Accelerator”. Journal of New Theory. 32 (September 1, 2020): 15-20. https://izlik.org/JA63MS37LK.
JAMA
1.Sarıkaya E, Gökbulut M, Guler G, Bozkurt H, Yiğitoğlu İ, Coşkun A. Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator. JNT. 2020;:15–20.
MLA
Sarıkaya, Elif, et al. “Measurement of Radiation Dose Emitted by 4 X 4 Cm2 and 10 X 10 Cm2 Aperture of Linear Accelerator”. Journal of New Theory, no. 32, Sept. 2020, pp. 15-20, https://izlik.org/JA63MS37LK.
Vancouver
1.Elif Sarıkaya, Melek Gökbulut, Gulhan Guler, Halis Bozkurt, İbrahim Yiğitoğlu, Arzu Coşkun. Measurement of Radiation Dose Emitted by 4 x 4 cm2 and 10 x 10 cm2 Aperture of Linear Accelerator. JNT [Internet]. 2020 Sep. 1;(32):15-20. Available from: https://izlik.org/JA63MS37LK