Does the overhang of tibial component in fixed bearing medial unicondylar knee arthroplasty affect 1-year results?
Abstract
Methods: Demographic data, preoperative and postoperative 1-year visual analog pain scale (VAS) and Oxford Knee Scores (OKS) were collected from 43 patients operated by a single surgeon with a fixed bearing UKA implant (Zimmer UKA, Warsaw USA) for this prospective cohort study. Patients were then grouped according to radiological compliance of the tibial component to the bone as perfect match or overhang, and the groups were compared in terms of pain and functional scores.
Results: Among 43 patients included in the study, 9 (20.9%) were males and 34 (79.1%) were females. The mean age of the patients was 62.1 (8.1) years. The median VAS and OKS scores of the patients before surgery were 6 (3-8) and 26 (21-30), respectively. Postoperatively, VAS score decreased to 1 (0-2), while OKS increased to 44 (37-48) (P<0.001 for both). There were only 3 patients with underhang. Twenty-two (52.1%) patients had perfect match and 18 (41.9%) had an overhang from the bone surface. There was no patient with an overhang greater than 3mm. The VAS and OKS scores at post-operative 1-year of 18 patients with overhang and 22 patients without bone overhang were similar (P=0.674 and P=0.873, respectively).
Conclusion: The overhang of the tibial component in fixed bearing unicondylar knee arthroplasty is common, however, this does not affect functional results in 1-year follow-up. Nevertheless, the sizing of the component should be checked by adequate means.
Keywords
References
- 1. Murray DW, Parkinson RW. Usage of unicompartmental knee arthroplasty. Bone Jt J. 2018;100-B:432–5.
- 2. Winnock de Grave P, Barbier J, Luyckx T, Ryckaert A, Gunst P, Van den Daelen L. Outcomes of a Fixed-Bearing, Medial, Cemented Unicondylar Knee Arthroplasty Design: Survival Analysis and Functional Score of 460 Cases. J Arthroplasty. 2018;33(9):2792–9. doi: 10.1016/j.arth.2018.04.031
- 3. Alnachoukati OK, Barrington JW, Berend KR, Kolczun MC, Emerson RH, Lombardi AV, Mauerhan DR. Eight Hundred Twenty-Five Medial Mobile-Bearing Unicompartmental Knee Arthroplasties: The First 10-Year US Multi-Center Survival Analysis. J Arthroplasty. 2018;33(3):677–83. doi: 10.1016/j.arth.2017.10.015
- 4. Emerson RH, Alnachoukati O, Barrington J, Ennin K. The results of Oxford unicompartmental knee arthroplasty in the United States. J BONE Jt Surg. 2006;34–40.
- 5. Chou DTS, Swamy GN, Lewis JR, Badhe NP. Revision of failed unicompartmental knee replacement to total knee replacement. Knee. 2012 Aug;19(4):356–9.
- 6. Kamenaga T, Hiranaka T, Kikuchi K, Hida Y, Fujishiro T, Okamoto K. Influence of tibial component rotation on short-term clinical outcomes in Oxford mobile-bearing unicompartmental knee arthroplasty. Knee. 2018;25(6):1222–30. doi: 10.1016/j.knee.2018.06.016
- 7. Nielsen CS, Nebergall A, Huddleston J, Kallemose T, Malchau H, Troelsen A. Medial Overhang of the Tibial Component Is Associated With Higher Risk of Inferior Knee Injury and Osteoarthritis Outcome Score Pain After Knee Replacement. J Arthroplasty. 2018;33(5):1394–8. doi: 10.1016/j.arth.2017.12.027
- 8. Simsek ME, Akkaya M, Gursoy S, Isik C, Zahar A, Tarabichi S, Bozkurt M. Posterolateral overhang affects patient quality of life after total knee arthroplasty. Arch Orthop Trauma Surg. 2018;138(3):409–18. doi: 10.1007/s00402-017-2850-4
Details
Primary Language
English
Subjects
Orthopaedics
Journal Section
Research Article
Authors
Hakan Kocaoğlu
*
0000-0002-1421-3555
Türkiye
Publication Date
July 1, 2020
Submission Date
July 17, 2020
Acceptance Date
July 27, 2020
Published in Issue
Year 2020 Volume: 4 Number: 7