Determination of Cd(II) Ions by using Cyclodextrin Based Polymeric Fluorescence Sensor
Abstract
In this study, Cd (II) ion
was determined using a cyclodextrin-based polymeric fluorescence sensor prepared
by UV-curing technique. The effects of several parameters such as pH, time, coexisting
ions on the fluorescence intensity were also examined. The excitation and
emission wavelengths were found to be 374 nm and 422 nm, respectively. The
measurement range was in the range of 4.45x10-9 mol L-1
to 4.45x10-8 mol L-1 for Cd(II) ions and the detection
limit was calculated as 6.23´10-10 mol L-1. In
addition, sensor membrane was selective which was not influenced by common coexisting
metal ions. The concentrations of the foreign ions such as Pb(II), Co(III),
Ag(I), Zn(II), Cu(II), Cr(III) are 1000-fold higher than Cd(II) ions. Besides
the prepared polymeric fluorescence sensor was successfully implemented to the
determination of Cd(II)ions in biscuit and tap water samples.
Keywords
References
- 6. Daşbaşı T, Saçmacı Ş, Ülgen A, Kartal A. A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry. Food Chem. 2015; 174:591–596.
- 7. Feist B, Mikula B, Pytlakowska K, Puzio B, Buhl F. Determination of heavy metals by ICP-OES and F-AAS after preconcentration with 2,2´-bipyridyl and erythrosine. J. Hazard. Mater. 2008; 152: 1122–1129. DOI: 10.1016/j.jhazmat.2007.07.095.
- 8. Ghaemi A, Tavakkoli H, Mombeni T. Fabrication of a Highly Selective Cadmium (II) Sensor Based on 1,13-bis(8quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore, Mater. Sci. Eng. 2014; 38:186-191. DOI: 10.1016/j.msec.2014.02.006.
- 9. Ivari ASR, Darroudi A. Ion Imprinted Polymer Based Potentiometric Sensor for the Trace Determination of Cadmium (II) Ions. Arabian J. Chem. 2013. DOI: 10.1016/j.arabjc.2012.12.021.
- Khani R, Ghiamati E, Boroujerdi R, Rezaeifard A, Zaryabi MH. A new and highly selective turn-on fluorescent sensorwith fast response time for the monitoring of cadmium ions in cosmetic, and health product samples. Spectrochim. Acta, Part A. 2016; 163:120–126. DOI: 10.1016/j.saa.2016.03.011.
- 1. Robards K, Worsfold P. Cadmium: toxicology and analysis. A review. The Analyst. 1991;116(6):549.
- 2. Ulah MR, Enamul Haque M. Spectrophotometric Determination Of Toxic Elements(Cadmium) In Aqueous Media. J. Chem. Eng. 2010; 25(1):1-12. DOI: 10.3329/jce.v25i0.7233.
- 3. Bulgariu L, Bulgariu D, Sarghie I. Spectrophotometric Determination of Cadmium(II) Using p,p′‐Dinitro‐SYM‐Diphenylcarbazid in Aqueous Solution. Anal. Lett. 2005; 38: 2365–2375. DOI:10.1080/00032710500316597.
Details
Primary Language
English
Subjects
Engineering, Chemical Engineering
Journal Section
Research Article
Authors
Soner Çubuk
MARMARA UNIV
Türkiye
Özge Yılmaz
This is me
MARMARA UNIV
Türkiye
Ece Kök Yetimoğlu
MARMARA UNIV
Türkiye
Memet Vezir Kahraman
MARMARA UNIV
Türkiye
Publication Date
April 11, 2017
Submission Date
February 13, 2017
Acceptance Date
April 4, 2017
Published in Issue
Year 2017 Volume: 4 Number: 2
Cited By
Application of Potentiometric Sensors in Real Samples
Critical Reviews in Analytical Chemistry
https://doi.org/10.1080/10408347.2019.1711013
