Effect of GLYMO/TEOS/MTEOS Sol-Gel Film Thickness on the Responses of Glucose Biosensor
Abstract
In the present study, the effect of the film thickness on the responses of a glucose biosensor was investigated. The modified platinum electrodes used in the study were constructed by immobilization of glucose oxidase under a film layer of the sol-gel coating solution. The sol-gel coating solutions were prepared by using (3-Glycidoxylpropyl) trimethoxysilane (GLYMO), tetraethoxysilane (TEOS), and methyltriethoxysilane (MTEOS). Electrochemical measurements were carried out amperometrically by determining hydrogen peroxide released by the enzymatic reaction between glucose and glucose oxidase. It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme. It was determined that the film thickness has a significantly influence on the sensor responses. It was observed that the amperometric responses decreased by 85% when the volume of the coating solution dropped on the electrode increased from 4 µL to 12 µL.
Keywords
References
- 1. Li J, Chia L.S., Goh N.K., Tan S.N., Ge H. Mediated amperometric glucose sensor modified by the sol-gel method, Sens Actuators B,1997;40:135-141. DOI:10.1016/S0925-4005(97)80252-3
- 2. Chaubey A, Malhotra B.D. Mediated biosensors, Biosens Bioelectron, 2002; 17:441-456. DOI:10.1016/S0956-5663(01)00313-X
- 3. Freire R.S., Pessoa C.A., Mello L.D., Kubota L.T. Direct electron transfer:An approach for electrochemical biosensors with higher selectivity and sensitivity, J Braz Chem Soc, 2003; 14:230-243. http://jbcs.sbq.org.br/imageBank/PDF/v14n2a08.pdf
- 4. Wang J. Electrochemical glucose biosensors, Chem Rev, 2008;108:814-825. DOI:10.1021/cr068123a
- 5. Collinson M.M. Analytical applications of organically modified silicates, Mikrochim Acta, 1998; 129:149-165. DOI:10.1007/BF01244737
- 6. Jin W, Brennan J.D., Properties and application of proteins encapsulated within sol-gel derived materials, Anal Chim Acta, 2002;461:1-36. DOI:10.1016/S0003-2670(02)00229-5
- 7. Thenmozhi K, Narayanan S.S. Electrochemical sensor for H2O2 based on thionin immobilized 3-aminopropyltrimethoxy silane derived sol-gel thin film electrode, Sens Actuators B, 2007; 125:195-201. DOI:10.1016/j.snb.2007.02.006
- 8. Tu Y.F., Di J.W., Chen X.J. Study of the nano-size silica sol-gel film as the matrix of chemically modified electrode, J Sol-Gel Sci Technol, 2005;33:187-191. DOI:10.1007/s10971-005-5613-6
Details
Primary Language
English
Subjects
Engineering
Journal Section
Research Article
Authors
Nizamettin Demirkıran
İnönü University
Türkiye
Ergun Ekinci
This is me
Inonu University
Türkiye
Publication Date
October 20, 2017
Submission Date
October 20, 2017
Acceptance Date
October 19, 2017
Published in Issue
Year 2017 Volume: 1 Number: Sp. is. 1
