Research Article

Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls

Volume: 6 Number: 2 June 30, 2021
EN

Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls

Abstract

Wood is preferred as building material in earthquake zones thanks to its light-weight. In countries with high seismic activity, wooden construction systems are required to be resistant to lateral and vertical loads. In traditional architecture, lateral load resistance is ensured with filled and unfilled walls which are strengthened with braces. In present day lateral load resistance is ensured with wooden shear walls formed by sheathings covered on the wall frame. Wooden shear walls may contain openings such as windows, doors and service channels. These types of openings reduce rigidity in wooden shear walls. The opening ratio, opening location, sheathing thickness and connection types have an impact on the lateral load bearing capacity of shear walls. This study investigates the use of two types of wooden shear walls with different-layout openings which were modelled with plywood sheathing material. For the purposes of this study, lateral load bearing capacities were calculated for both types of sheathing material of different thicknesses. The results are presented in tables by comparing the calculated capacity increase to the increase in weight.

Keywords

References

  1. 1. Swetha, K. S., & Akhil, P. A. (2017). Effect of Openings in Shear Wall. International Research Journal of Engineering and Technology (IRJET) Volume, 4.
  2. 2. Kankuntla, A. Sangave, P., & Chavan, R. (2016). Effects of Openings in Shear Wall on Seismic Response of Structures, Int. J. Comput. Appl., vol. 13, no. 1, pp. 10–15, 2016, doi: 10.9790/1684-13120106
  3. 3. Trimble Tekla Tedds. (2013). Timber Frame Racking Panel Design.
  4. 4. Güngör, İ. H. (1961). Ahşap Yapı Bilgisi, İTÜ Teknik Okulu.
  5. 5. Aktaş, Y. D., Akyüz, U., Türer, A., Erdil, B., & Güçhan, N. A. (2014). Seismic Resistance Evaluation of Traditional Ottoman Timber-Frame Hımış Houses: Frame Loadings and Material Tests. Earthquake Spectra, 30(4), 1711–1732. https://doi.org/10.1193/011412eqs011m
  6. 6. Aksoy, D., & Z. Ahunbay, Z. (2005). Geleneksel ahşap iskeletli Türk Konutu’ nun deprem davranışları, No. 1999, pp. 47–58.
  7. 7. National Institute of Standards and Technology (1996). The January 17, 1995 Hyogoken-Nanbu (Kobe) Earthquake.
  8. 8. Bertero, V. V., Borcherdt, R. D., Clark, P. W., Dreger, D. S., Filippou, F. C., Foutch, D. A., ... & Xiao, Y. (1995). Seismological and engineering aspects of the 1995 Hyogoken-Nanbu (Kobe) earthquake. Report UCB/EERC-95/10, Earthquake Engineering Research Center, University of California, Berkeley.

Details

Primary Language

English

Subjects

-

Journal Section

Research Article

Publication Date

June 30, 2021

Submission Date

April 20, 2021

Acceptance Date

June 23, 2021

Published in Issue

Year 2021 Volume: 6 Number: 2

APA
Demirkıran, E. K., Gür, N. V., & Ökten, M. S. (2021). Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. Journal of Sustainable Construction Materials and Technologies, 6(2), 70-80. https://doi.org/10.29187/jscmt.2021.62
AMA
1.Demirkıran EK, Gür NV, Ökten MS. Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. JSCMT. 2021;6(2):70-80. doi:10.29187/jscmt.2021.62
Chicago
Demirkıran, Erdem Kazım, Nabi Volkan Gür, and Mehmet Selim Ökten. 2021. “Effect of Opening Layout and Sheathing on Lateral Load Bearing Capacity in Wooden Shear Walls”. Journal of Sustainable Construction Materials and Technologies 6 (2): 70-80. https://doi.org/10.29187/jscmt.2021.62.
EndNote
Demirkıran EK, Gür NV, Ökten MS (June 1, 2021) Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. Journal of Sustainable Construction Materials and Technologies 6 2 70–80.
IEEE
[1]E. K. Demirkıran, N. V. Gür, and M. S. Ökten, “Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls”, JSCMT, vol. 6, no. 2, pp. 70–80, June 2021, doi: 10.29187/jscmt.2021.62.
ISNAD
Demirkıran, Erdem Kazım - Gür, Nabi Volkan - Ökten, Mehmet Selim. “Effect of Opening Layout and Sheathing on Lateral Load Bearing Capacity in Wooden Shear Walls”. Journal of Sustainable Construction Materials and Technologies 6/2 (June 1, 2021): 70-80. https://doi.org/10.29187/jscmt.2021.62.
JAMA
1.Demirkıran EK, Gür NV, Ökten MS. Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. JSCMT. 2021;6:70–80.
MLA
Demirkıran, Erdem Kazım, et al. “Effect of Opening Layout and Sheathing on Lateral Load Bearing Capacity in Wooden Shear Walls”. Journal of Sustainable Construction Materials and Technologies, vol. 6, no. 2, June 2021, pp. 70-80, doi:10.29187/jscmt.2021.62.
Vancouver
1.Erdem Kazım Demirkıran, Nabi Volkan Gür, Mehmet Selim Ökten. Effect of opening layout and sheathing on lateral load bearing capacity in wooden shear walls. JSCMT. 2021 Jun. 1;6(2):70-8. doi:10.29187/jscmt.2021.62

Cited By