BibTex RIS Cite
Year 2016, Volume: 1 Issue: 1, 16 - 22, 23.05.2016

Abstract

References

  • ČSN EN 15780 – Ventilation for buildings - Ductwork - Cleanliness of ventilation systems.
  • RUBINA, A.; UHER, P., Cleaning the air handling units, article in Topenářství, ISSN 1211-0906, Technické vydavatelství Praha, spol. s r.o., Praha, 2014
  • RUBINA, A.; UHER, P.; HIRŠ, J., Methodology for the design, manufacture, installation and operation of the air handling units in hygienic design, spec. publication, ISBN 80-903586-5-9, Litera Brno, Brno, 2013
  • BJÖRKROTH, M., V. ASIKAINEN, O. SEPPÄNEN. Cleanliness criteria and test procedures for cleanliness labelling of HVAC components. In: Indoor Air 2002 The 9th International Conference on Indoor Air Quality and Climate. Monterey, California: 2001, s. 6.
  • HOLOPAINEN, R., M. TUOMAINEN, V. ASIKAINEN. The effect of cleanliness control during installation work on the amount of accumulated dust in ducts of new HVAC installations. In: Indoor Air 2002 The 9th International Conference on Indoor Air Quality and Climate. Monterey, California: 2001, s. 7.
  • ASIKAINENA, V., R. HOLOPAINENB, A. MAJANENB. The verifying concept for the cleanliness of HVAC systems. In: Lifa air [online]. 2015 [cit. 2015-06-24]. Available from: http://www.lifa.net/research/poster3_LIFA_verifying_concept.pdf

Cleanliness of ventilation ducts, indoor space and AHU

Year 2016, Volume: 1 Issue: 1, 16 - 22, 23.05.2016

Abstract

Paper deals with analysis of cleanliness air conditioning duct for various stages of construction. There were taken samples and these were analyzed for different type of storage duct on construction. They are compared differences between the "right" stored duct and unprotected duct including the actual interior space and air handling units serving. In the conclusion of this article is summarized the impact of carryover dirt from the duct and an air handling unit to the ventilation system.

References

  • ČSN EN 15780 – Ventilation for buildings - Ductwork - Cleanliness of ventilation systems.
  • RUBINA, A.; UHER, P., Cleaning the air handling units, article in Topenářství, ISSN 1211-0906, Technické vydavatelství Praha, spol. s r.o., Praha, 2014
  • RUBINA, A.; UHER, P.; HIRŠ, J., Methodology for the design, manufacture, installation and operation of the air handling units in hygienic design, spec. publication, ISBN 80-903586-5-9, Litera Brno, Brno, 2013
  • BJÖRKROTH, M., V. ASIKAINEN, O. SEPPÄNEN. Cleanliness criteria and test procedures for cleanliness labelling of HVAC components. In: Indoor Air 2002 The 9th International Conference on Indoor Air Quality and Climate. Monterey, California: 2001, s. 6.
  • HOLOPAINEN, R., M. TUOMAINEN, V. ASIKAINEN. The effect of cleanliness control during installation work on the amount of accumulated dust in ducts of new HVAC installations. In: Indoor Air 2002 The 9th International Conference on Indoor Air Quality and Climate. Monterey, California: 2001, s. 7.
  • ASIKAINENA, V., R. HOLOPAINENB, A. MAJANENB. The verifying concept for the cleanliness of HVAC systems. In: Lifa air [online]. 2015 [cit. 2015-06-24]. Available from: http://www.lifa.net/research/poster3_LIFA_verifying_concept.pdf
There are 6 citations in total.

Details

Other ID JA22ED74TE
Journal Section Research Articles
Authors

Aleš Rubina This is me

Olga Rubinová This is me

Petr Blasinski This is me

Publication Date May 23, 2016
Submission Date May 23, 2016
Published in Issue Year 2016 Volume: 1 Issue: 1

Cite

APA Rubina, A., Rubinová, O., & Blasinski, P. (2016). Cleanliness of ventilation ducts, indoor space and AHU. Journal of Sustainable Construction Materials and Technologies, 1(1), 16-22.

88x31_3.png

Journal of Sustainable Construction Materials and Technologies is open access journal under the CC BY-NC license  (Creative Commons Attribution 4.0 International License)

Based on a work at https://dergipark.org.tr/en/pub/jscmt

E-mail: jscmt@yildiz.edu.tr