Research Article
BibTex RIS Cite

A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy

Year 1993, Volume: 6 Issue: 1, 6 - 9, 01.01.1993

Abstract

Electroconvulsive therapy has recently been applied under general anesthesia for the treatment of many psychiatric diseases as depression. In our study, we aimed to compare the induction and recovery times, duration of convulsion, arterial blood pressure and heart rate values in 10 psychiatric patients, 5 of whom were female. Electroconvulsive therapies are induced with thiopentone sodium or propofol. The recovery time was found to be 17.45 ± 1.97 minute for propofol and 24.15 ± 2.00 minute for thiopentone sodium. The mean convulsion time for propofol being 20.85 ± 2.5 second was significantly shorter than that for thiopentone sodium being 26.6 ± 2.1 second. A significant increase in arterial blood pressure after electroconvulsive therapy were recorded for both agents, yet the increase was more with thiopentone sodium. Finally, because all the patients included in our study showed a good prognosis, we believe that propofol might be beneficial for those patients who have cardiovascular problems; however concerning the effect of duration of convulsion on therapy, it was concluded that further studies must be started on a broader spectrum of patients.

References

  • dairies QY Hi. Rees Dl. Electroconvulsive therapy and anesthetic considerations. Anesth Analg 1986;65:1345-1356.
Year 1993, Volume: 6 Issue: 1, 6 - 9, 01.01.1993

Abstract

References

  • dairies QY Hi. Rees Dl. Electroconvulsive therapy and anesthetic considerations. Anesth Analg 1986;65:1345-1356.
There are 1 citations in total.

Details

Subjects Clinical Sciences
Journal Section Derleme
Authors

F.Y. Göğüş This is me

O. Kanbak This is me

Y. Yazgan This is me

Publication Date January 1, 1993
Published in Issue Year 1993 Volume: 6 Issue: 1

Cite

APA Göğüş, F., Kanbak, O., & Yazgan, Y. (1993). A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy. Marmara Medical Journal, 6(1), 6-9.
AMA Göğüş F, Kanbak O, Yazgan Y. A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy. Marmara Med J. January 1993;6(1):6-9.
Chicago Göğüş, F.Y., O. Kanbak, and Y. Yazgan. “A Comparison of the Effects of Propofol and Thiopentone in Modified Electroconvulsive Therapy”. Marmara Medical Journal 6, no. 1 (January 1993): 6-9.
EndNote Göğüş F, Kanbak O, Yazgan Y (January 1, 1993) A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy. Marmara Medical Journal 6 1 6–9.
IEEE F. Göğüş, O. Kanbak, and Y. Yazgan, “A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy”, Marmara Med J, vol. 6, no. 1, pp. 6–9, 1993.
ISNAD Göğüş, F.Y. et al. “A Comparison of the Effects of Propofol and Thiopentone in Modified Electroconvulsive Therapy”. Marmara Medical Journal 6/1 (January 1993), 6-9.
JAMA Göğüş F, Kanbak O, Yazgan Y. A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy. Marmara Med J. 1993;6:6–9.
MLA Göğüş, F.Y. et al. “A Comparison of the Effects of Propofol and Thiopentone in Modified Electroconvulsive Therapy”. Marmara Medical Journal, vol. 6, no. 1, 1993, pp. 6-9.
Vancouver Göğüş F, Kanbak O, Yazgan Y. A comparison of the effects of propofol and thiopentone in modified electroconvulsive therapy. Marmara Med J. 1993;6(1):6-9.