Research Article
BibTex RIS Cite

High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate

Year 2016, Volume: 29 Issue: 3, 189 - 191, 15.10.2016

Abstract

We present a case of neonatal pericardial tamponade due to umbilical

venous catheterization, a rare, but life threatening complication.

A newborn who developed sudden clinical deterioration at 44th

hour following umbilical venous catheterization, is reported.

Echocardiography showed marked pericardial effusion. Urgent

pericardiocentesis was performed. Analysis of pericardial fluid

revealed high glucose level consistent with the composition of

total parenteral nutrition fluid being infused through the catheter.

Pericardial tamponade should be considered in any infant with

a central venous catheter who suddenly deteriorates and urgent

pericardiocentesis should be attempted.

References

  • Green C, Yohannan MD. Umbilical arterial and venous catheters: placement, use, and complications. Neonatal Netw 1998; 17:23-8.

Perikard sıvısında yüksek glukoz konsantrasyonu: Yenidoğanda iyatrojenik perikardiyal tamponadın bir belirteci

Year 2016, Volume: 29 Issue: 3, 189 - 191, 15.10.2016

Abstract

Umbilikal venöz kateterizasyon işlemi sonrasında gelişen nadir

fakat yaşamı tehdit edici komplikasyonlardan biri perikardiyal

tamponaddır. Yenidoğan bir bebekte umbilikal venöz kateterizasyon

işlemi sonrasında ani klinik kötüleşme ile prezente olan

perikardiyal tamponad olgusunu sunuyoruz. Ekokardiyografide

geniş perikardiyal effüzyon görülmüş ve acil perikardiyosentez

yapılmıştır. Perikardiyal sıvı analizinde umbilikal kateterden

gitmekte olan sıvı içeriğinin konsantrasyonunda glukoz

seviyesi bildirilmiştir. Perikardiyal tamponad, umbilikal venöz

kateterizasyon sonrasında ani klinik kötüleşme gösteren her

hastada akla gelmelidir ve acil perikardiyosentez uygulanmalıdır.

References

  • Green C, Yohannan MD. Umbilical arterial and venous catheters: placement, use, and complications. Neonatal Netw 1998; 17:23-8.
There are 1 citations in total.

Details

Subjects Clinical Sciences
Journal Section Derleme
Authors

Elif Erolu Gunay This is me

Aslı Memısoglu This is me

Sinem Altınyuva Usta This is me

Oyku Tosun This is me

Koray Ak This is me

Figen Akalın This is me

Publication Date October 15, 2016
Published in Issue Year 2016 Volume: 29 Issue: 3

Cite

APA Erolu Gunay, E., Memısoglu, A., Altınyuva Usta, S., Tosun, O., et al. (2016). High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate. Marmara Medical Journal, 29(3), 189-191. https://doi.org/10.5472/MMJcr.2903.04
AMA Erolu Gunay E, Memısoglu A, Altınyuva Usta S, Tosun O, Ak K, Akalın F. High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate. Marmara Med J. October 2016;29(3):189-191. doi:10.5472/MMJcr.2903.04
Chicago Erolu Gunay, Elif, Aslı Memısoglu, Sinem Altınyuva Usta, Oyku Tosun, Koray Ak, and Figen Akalın. “High Glucose Concentration in Pericardial Fluid: An Indication for Iatrogenic Cardiac Tamponade in a Neonate”. Marmara Medical Journal 29, no. 3 (October 2016): 189-91. https://doi.org/10.5472/MMJcr.2903.04.
EndNote Erolu Gunay E, Memısoglu A, Altınyuva Usta S, Tosun O, Ak K, Akalın F (October 1, 2016) High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate. Marmara Medical Journal 29 3 189–191.
IEEE E. Erolu Gunay, A. Memısoglu, S. Altınyuva Usta, O. Tosun, K. Ak, and F. Akalın, “High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate”, Marmara Med J, vol. 29, no. 3, pp. 189–191, 2016, doi: 10.5472/MMJcr.2903.04.
ISNAD Erolu Gunay, Elif et al. “High Glucose Concentration in Pericardial Fluid: An Indication for Iatrogenic Cardiac Tamponade in a Neonate”. Marmara Medical Journal 29/3 (October 2016), 189-191. https://doi.org/10.5472/MMJcr.2903.04.
JAMA Erolu Gunay E, Memısoglu A, Altınyuva Usta S, Tosun O, Ak K, Akalın F. High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate. Marmara Med J. 2016;29:189–191.
MLA Erolu Gunay, Elif et al. “High Glucose Concentration in Pericardial Fluid: An Indication for Iatrogenic Cardiac Tamponade in a Neonate”. Marmara Medical Journal, vol. 29, no. 3, 2016, pp. 189-91, doi:10.5472/MMJcr.2903.04.
Vancouver Erolu Gunay E, Memısoglu A, Altınyuva Usta S, Tosun O, Ak K, Akalın F. High glucose concentration in pericardial fluid: An indication for iatrogenic cardiac tamponade in a neonate. Marmara Med J. 2016;29(3):189-91.