Aim: Currently, one of the most promising research areas in dental implantology is the exploration of additional procedures to reduce loading time for implants and enhance osseointegration in cases of poor bone quality. Various techniques have been researched and developed for stimulating bone production, including electrical stimulation of the jawbone and surrounding tissues. However, there is limited research on the direct relationship between electrostimulation and osseointegration. This experimental study aims to investigate the effects of corona stimulation (CS) on the rate and quality of osseointegration, as well as its potential to reduce the waiting period for dental implants.
Material and Method: In this experimental protocol, 32 dental implants were inserted into the tibia of four male sheep bilaterally. Implants on the right tibia of each male sheep underwent CS treatment, while the other side served as a control group without any stimulation. The animals were sacrificed on the 15th and 30th days after implantation. Bone segments containing the implants were processed using a noncalcified method. It assessed new bone formation and osseointegration around the dental implants using the undecalcified method and histomorphological analysis. An experienced blinded investigator measured percentages of mineralized bone-implant contact (BIC), bone area (BAr), and bone perimeter (BPm) to evaluate the bone-implant interface. Statistical analyses were performed using SPSS 21 for Windows, with a significance level set at p<0.05.
Results: The histomorphometric parameters revealed a significant increase in BIC, BAr, and BPm values in the CS group compared to the control group on both the 15th and 30th days (p<0.05). There was no statistically significant difference in BIC ratio between the second and fourth stimulation groups.
Conclusion: The findings of this experimental study suggest that CS may have a positive impact on the early osseointegration period of dental implants.
The experimental protocol commenced following approval from the İstanbul University Animal Experiments Local Ethics Committee, under the reference number 2014/77, on July 18, 2014.
Funding for this study was provided by the Scientific Research Project Unit of İstanbul University (BAP project no. 49665). The implants utilized in this research were sourced from Zimmer® (USA).
BAP project no. 49665
BAP project no. 49665
Primary Language | English |
---|---|
Subjects | Facial Plastic Surgery |
Journal Section | Original Articles |
Authors | |
Project Number | BAP project no. 49665 |
Publication Date | January 31, 2024 |
Acceptance Date | November 4, 2023 |
Published in Issue | Year 2024 Volume: 6 Issue: 1 |
Chief Editors
MD, Professor. Berkant Özpolat
Department of Thoracic Surgery, Ufuk University, Dr. Rıdvan Ege Hospital, Ankara, Türkiye
Editors
MD, Professor. Sercan Okutucu
Department of Cardiology, Ankara Lokman Hekim University, Ankara, Türkiye
MD, Assoc. Prof. Süleyman Cebeci
Department of Ear, Nose and Throat Diseases, Gazi University Faculty of Medicine, Ankara, Türkiye
Field Editors
MD, Assoc. Prof. Doğan Öztürk
Department of General Surgery, Manisa Özel Sarıkız Hospital, Manisa, Türkiye
MD, Assoc. Prof. Birsen Doğanay
Department of Cardiology, Ankara Bilkent City Hospital, Ankara, Türkiye
MD, Assoc. Prof. Sonay Aydın
Department of Radiology, Erzincan Binali Yıldırım University Faculty of Medicine, Erzincan, Türkiye
Language Editors
PhD, Dr. Evin Mise
Department of Work Psychology, Ankara University, Ayaş Vocational School, Ankara, Türkiye
Dr. Dt. Çise Nazım
Department of Periodontology, Dr. Burhan Nalbantoğlu State Hospital, Lefkoşa, North Cyprus
Statistics Editor
PhD, Dr. Nurbanu Bursa
Department of Statistics, Hacettepe University, Faculty of Science, Ankara, Türkiye
Scientific Publication Coordinator
Kübra Toğlu
argistyayincilik@gmail.com
Franchise Owner
Argist Yayıncılık
argistyayincilik@gmail.com
Publisher: Argist Yayıncılık
E-mail: argistyayincilik@gmail.com
Phone: 0 533 320 32 09/0 312 979 02 35
Address: Kızılırmak Mahallesi Dumlupınar Bulvarı No:3 C-1 160 Çankaya/Ankara, Türkiye
Web: www.argistyayin.com.tr