Research Article

INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA

Volume: 9 Number: 2 December 29, 2023
EN

INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA

Abstract

Introduction: Cadmium Zinc Telluride (CZT) Cardiac Cameras are a special SPECT cameras with solid state cadmium zinc telluride detectors. This diagnostic method applied in the evaluation of coronary artery disease is well designed for myocardial perfusion scintigraphy. Aim: CZT cardiac cameras have limited detector area. In patients who are morbidly obese or whose heart is not in its normal location in the body, the center of the heart and the isocenter of the device do not coincide. It is aim to investigate how these conditions affect the imaging performance of the CZT cardiac camera. Methods: A homogeneous and spherical ball with a diameter of 4 cm was used for the research. To be able to measure away from the center a wooden phantom with 8 cavities and a total length of 32 cm was designed. The center as reference point has been determined by matching the center of the device with the center of the sphere. For the next imaging, the image were taken by placing the spherical ball in the other cavities, respectively, without changing the center. Results: According to the results obtained, farther from the center, deviations from sphericity and differences in dose distribution were observed. Counts decreased by 1.5% in the 2nd position and 16% in the 3rd position relative to the center in the X-axis. A disaster area has been formed and the image area has been exited from the 4th imaging. Conclusion: It is very important to center the patient as much as possible, otherwise the doctor will misdiagnose.

Keywords

References

  1. Ben-Haim, S., Kennedy, J., Keidar. Z., “Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging-Technological Aspects and Clinical Applications”, Seminars in Nuclear Medicine, 46(4):273-85, 2016.
  2. Baumgarten, R., et al., “Radiation exposure after myocardial perfusion imaging with Cadmium-Zinc-Telluride camera versus conventional camera”, J Nucl Cardiol., 28(3):992-999, 2020.
  3. Henzlova M.J., Duvall L., “Is the CZT technology the future of nuclear cardiology?” Journal of Nuclear Cardiology, 29:737–740, 2020.
  4. Duncker, D.J., Koller, A., Merkus, D., Cantry Jr J.M., “Regulation of coronary blood flow in health and ischemic heart disease”, Progress in Cardiovascular Diseases, 57(5):409-422, 2015.
  5. Agostini, D., et al., “Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)”, Eur J Nucl Med Mol Imaging, 43(13):2423-2432, 2016.
  6. Zhang, Y.Q., et al. “Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery disease: A PRISMA-compliant meta-analysis”, Medicine (Baltimore), 98(9): e14716, 2019.
  7. Zhang H., et al., “Left ventricular mechanical dyssynchrony assessment in obese patients using the cadmium-zinc telluride SPECT camera”, The International Journal of Cardiovascular Imaging, 36(4):757–765, 2020.
  8. Ljungberg M., Pretorius H., “SPECT/CT: an update on technological developments and clinical applications”, British Institute of Radiology, 91(1081):20160402, 2018.

Details

Primary Language

English

Subjects

Metrology, Applied and Industrial Physics

Journal Section

Research Article

Publication Date

December 29, 2023

Submission Date

March 23, 2023

Acceptance Date

July 25, 2023

Published in Issue

Year 2023 Volume: 9 Number: 2

APA
Mutlu, E., Kovan, B., Işık, E. G., Kuyumcu, S., & Demir, B. (2023). INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA. Middle East Journal of Science, 9(2), 57-66. https://doi.org/10.51477/mejs.1269886
AMA
1.Mutlu E, Kovan B, Işık EG, Kuyumcu S, Demir B. INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA. MEJS. 2023;9(2):57-66. doi:10.51477/mejs.1269886
Chicago
Mutlu, Eda, Bilal Kovan, Emine Göknur Işık, Serkan Kuyumcu, and Bayram Demir. 2023. “INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA”. Middle East Journal of Science 9 (2): 57-66. https://doi.org/10.51477/mejs.1269886.
EndNote
Mutlu E, Kovan B, Işık EG, Kuyumcu S, Demir B (December 1, 2023) INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA. Middle East Journal of Science 9 2 57–66.
IEEE
[1]E. Mutlu, B. Kovan, E. G. Işık, S. Kuyumcu, and B. Demir, “INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA”, MEJS, vol. 9, no. 2, pp. 57–66, Dec. 2023, doi: 10.51477/mejs.1269886.
ISNAD
Mutlu, Eda - Kovan, Bilal - Işık, Emine Göknur - Kuyumcu, Serkan - Demir, Bayram. “INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA”. Middle East Journal of Science 9/2 (December 1, 2023): 57-66. https://doi.org/10.51477/mejs.1269886.
JAMA
1.Mutlu E, Kovan B, Işık EG, Kuyumcu S, Demir B. INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA. MEJS. 2023;9:57–66.
MLA
Mutlu, Eda, et al. “INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA”. Middle East Journal of Science, vol. 9, no. 2, Dec. 2023, pp. 57-66, doi:10.51477/mejs.1269886.
Vancouver
1.Eda Mutlu, Bilal Kovan, Emine Göknur Işık, Serkan Kuyumcu, Bayram Demir. INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA. MEJS. 2023 Dec. 1;9(2):57-66. doi:10.51477/mejs.1269886

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License

TRDizinlogo_live-e1586763957746.png   ici2.png     scholar_logo_64dp.png    CenterLogo.png     crossref-logo-landscape-200.png  logo.png         logo1.jpg   DRJI_Logo.jpg  17826265674769  logo.png