THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS
Öz
This study deals with the thermo-economic optimization of superheating and sub-cooling heat exchangers in vapor compressed refrigeration system. Using for R22 and its alternative refrigerants (R410A and R407C), the temperature of condenser at the interval of (35°C – 55°C) and temperature of evaporator at the interval of (-10°C – 10°C) have been obtained from the calculation process. The second law analysis of refrigeration system is carried out and then the whole system is optimized by thermo-economically. As a result of calculations, optimum superheating and sub-cooling temperatures of heat exchangers areas corresponding to these temperatures are obtained. Keywords: Thermo-economy, optimization, alternative refrigerants (R410A and R407C)
Anahtar Kelimeler
Details
Primary Language
Turkish
Subjects
-
Journal Section
-
Publication Date
March 1, 2010
Submission Date
August 29, 2014
Acceptance Date
-
Published in Issue
Year 2010 Volume: 5 Number: 2
APA
Özkaymak, M., Acar, B., & Özkaya, M. G. (2010). THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences, 5(2), 381-398. https://doi.org/10.12739/nwsaes.v5i2.5000067101
AMA
1.Özkaymak M, Acar B, Özkaya MG. THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences. 2010;5(2):381-398. doi:10.12739/nwsaes.v5i2.5000067101
Chicago
Özkaymak, Mehmet, Bahadır Acar, and Musa Galip Özkaya. 2010. “THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS”. Engineering Sciences 5 (2): 381-98. https://doi.org/10.12739/nwsaes.v5i2.5000067101.
EndNote
Özkaymak M, Acar B, Özkaya MG (March 1, 2010) THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences 5 2 381–398.
IEEE
[1]M. Özkaymak, B. Acar, and M. G. Özkaya, “THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS”, Engineering Sciences, vol. 5, no. 2, pp. 381–398, Mar. 2010, doi: 10.12739/nwsaes.v5i2.5000067101.
ISNAD
Özkaymak, Mehmet - Acar, Bahadır - Özkaya, Musa Galip. “THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS”. Engineering Sciences 5/2 (March 1, 2010): 381-398. https://doi.org/10.12739/nwsaes.v5i2.5000067101.
JAMA
1.Özkaymak M, Acar B, Özkaya MG. THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences. 2010;5:381–398.
MLA
Özkaymak, Mehmet, et al. “THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS”. Engineering Sciences, vol. 5, no. 2, Mar. 2010, pp. 381-98, doi:10.12739/nwsaes.v5i2.5000067101.
Vancouver
1.Mehmet Özkaymak, Bahadır Acar, Musa Galip Özkaya. THERMO-ECONOMYC OPTYMYZATYON OF A VAPOUR COMPRESSED REFRYGERATYON SYSTEM USYNG ALTERNATYVE REFRYGERANTS. Engineering Sciences. 2010 Mar. 1;5(2):381-98. doi:10.12739/nwsaes.v5i2.5000067101